ALLERGENICITY SUPPRESSION IN NATURAL LATEX SURGICAL GLOVES

被引:30
|
作者
LEYNADIER, F
XUAN, TT
DRY, J
机构
[1] HOP ROTHSCHILD, CTR ALLERGY, F-75571 PARIS 12, FRANCE
[2] LAB STALLERGENES, FRESNES, FRANCE
关键词
ALLERGENICITY; ANAPHYLAXIS; ELECTRICAL CONDUCTIVITY; LATEX GLOVES;
D O I
10.1111/j.1398-9995.1991.tb00633.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
By a revised manufacturing process we aimed to obtain latex surgical gloves without immediate allergenicity, and also to determine a simple physical technique by which to estimate this allergenicity. Five glove samples were evaluated for allergenicity by physical and biochemical methods and by skin tests at the University Allergy Centre. Three groups of allergic patients with documented anaphylaxis to surgical gloves, positive skin test to latex extract and specific IgE to latex (RAST Pharmacia greater-than-or-equal-to class II), volunteered for the study. The protein content, the in vitro allergenic potency of glove supernatants (RAST inhibition) and the skin test results with glove supernatants were lower in washed gloves than in non-washed samples (P < 0.02 to P < 0.009). The supplementary effect of glove sterilization at 120-degrees-C (for 1 h in saturated steam) was obvious. The protein content became undetectable in four of the five glove supernatants, and skin tests results with sample supernatants were decreased (M +/- SEM = 0.68 +/- 0.29 mm vs 3.06 +/- 0.61 mm with non-sterilized gloves), P < 0.009 by Wilcoxon test. With the Spearman test there was a significant correlation (P = 0.029) between the mean wheal size, obtained with supernatants (Groups 1 and 2) and electrical conductivity. Skin tests through pieces of gloves randomly distributed and coded were decreased by sterilization: 0.66 +/- 0.25 mm vs 2.86 +/- 0.45 mm, P < 0.0001. Thus, it is possible to decrease glove allergenicity by washing them after mould forming and then sterilizing with steam. Electrical conductivity may be a simple parameter for revealing allergenicity.
引用
收藏
页码:619 / 625
页数:7
相关论文
共 50 条
  • [31] THE BURGEONING PROBLEM OF LATEX SENSITIVITY - SURGICAL GLOVES ARE ONLY THE BEGINNING
    WEIDO, AJ
    SIM, TC
    [J]. POSTGRADUATE MEDICINE, 1995, 98 (03) : 173 - &
  • [32] ALLERGY TO LATEX SURGICAL GLOVES - AN UNFAMILIAR CAUSE OF INTRAOPERATIVE ANAPHYLAXIS
    BARAKAT, RR
    SARARIAN, K
    SHEPHERD, G
    WEINBERGER, M
    HOSKINS, WJ
    [J]. GYNECOLOGIC ONCOLOGY, 1992, 46 (03) : 381 - 383
  • [33] The effect of polymethyl methacrylate on latex-free surgical gloves
    Edwards, TB
    Habetz, S
    D'Ambrosia, RD
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (04): : 541 - 542
  • [34] Latex allergen elimination in natural latex sap and latex gloves by treatment with alkaline potassium hydroxide solution
    Baur, X
    Rennert, J
    Chen, Z
    [J]. ALLERGY, 1997, 52 (03) : 306 - 311
  • [35] Overview on the potential of Biodegradable Natural Rubber Latex Gloves for commercialization
    Misman, M. A.
    Azura, A. R.
    [J]. ADVANCES IN RUBBER, 2014, 844 : 486 - 489
  • [36] An assessment of the endotoxin contents of Natural Rubber latex medical gloves
    Ikram, A.
    Amir-Hashim, M. Y.
    [J]. JOURNAL OF RUBBER RESEARCH, 2008, 11 (01) : 29 - 35
  • [37] ALLERGENICITY OF LATEX PACIFIERS
    TURJANMAA, K
    MAKINENKILJUNEN, S
    REUNALA, T
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1993, 91 (01) : 270 - 270
  • [38] Endotoxins in the Manufacturing Environments of Natural Rubber (NR) Latex Gloves
    Aziana, A. H.
    Ikram, A.
    Mok, K. L.
    Amir-Hashim, M. Y.
    [J]. JOURNAL OF RUBBER RESEARCH, 2011, 14 (01) : 11 - 23
  • [39] Casein, an additional allergen in natural rubber latex gloves.
    Mäkinen-Kiljunen, S
    Ylitalo, L
    Turjanmaa, K
    Palosuo, T
    Reunala, T
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (01) : S124 - S124
  • [40] REUSABLE LATEX GLOVES