Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

被引:18
|
作者
Bugbee, William D. [1 ]
Mizu-uchi, Hideki [2 ]
Patil, Shantanu [2 ]
D'Lima, Darryl [2 ]
机构
[1] Scripps Clin, Div Orthopaed Surg, 10666 North Torrey Pines Rd,MS116, La Jolla, CA 92037 USA
[2] Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA 92037 USA
关键词
D O I
10.1155/2013/891210
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Customized patient instrumentation (CPI) combines preoperative planning with customized cutting jigs to position and align implants during total knee arthroplasty (TKA). We compared postoperative implant alignment of patients undergoing surgery with CPI to traditional TKA instrumentation for accuracy of implant placement. Twenty-five consecutive TKAs using CPI were analyzed. Preoperative CT scans of the lower extremities were segmented using a computer program. Limb alignment and mechanical axis were computed. Virtual implantation of computer-aided design models was done. Postoperative coronal and sagittal view radiographs were obtained. Using 3D image-matching software, relative positions of femoral and tibial implants were determined. Twenty-five TKAs implanted using traditional instrumentation were also analyzed. For CPI, difference in alignment from the preoperative plan was calculated. In the CPI group, the mean absolute difference between the planned and actual femoral placements was 0.67 degrees in the coronal plane and 1.2 degrees in the sagittal plane. For tibial alignment, the mean absolute difference was 0.9 degrees in the coronal plane and 1.3 degrees in the sagittal plane. For traditional instrumentation, difference from ideal placement for the femur was 1.5 degrees in the coronal plane and 2.3 degrees in the sagittal plane. For the tibia, the difference was 1.8 degrees in the coronal plane. CPI achieved accurate implant positioning and was superior to traditional TKA instrumentation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Does Implant Design Influence the Accuracy of Patient Specific Instrumentation in Total Knee Arthroplasty?
    Goyal, Nitin
    Patel, Anay R.
    Yaffe, Mark A.
    Luo, Michael Y.
    Stulberg, S. David
    JOURNAL OF ARTHROPLASTY, 2015, 30 (09): : 1526 - 1530
  • [2] Accuracy of Patient-Specific Instrumentation Compared With Conventional Instrumentation in Total Knee Arthroplasty
    Jiang, Jin
    Kang, Xin
    Lin, Qiao
    Teng, Yuanjun
    An, Liping
    Ma, Jingling
    Wang, Jing
    Xia, Yayi
    ORTHOPEDICS, 2015, 38 (04) : E305 - E313
  • [3] Patient-Specific Instrumentation Does Not Improve Accuracy in Total Knee Arthroplasty
    Shen, Chong
    Tang, Zhi-Hong
    Hu, Jun-Zu
    Zou, Guo-Yao
    Xiao, Rong-Chi
    Yan, Dong-Xue
    ORTHOPEDICS, 2015, 38 (03) : E178 - E188
  • [4] Implant placement accuracy in total knee arthroplasty: validation of a CT-based measurement technique
    Campanelli, Valentina
    Lozano, Rocio
    Akhlaghpour, Hosna
    Brar, Abheetinder S.
    Maislin, David
    Nedopil, Alexander J.
    Zuhars, Joel
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (02) : 475 - 484
  • [5] Patient-specific instrumentation in total knee arthroplasty
    Mathis, Dominic T.
    Hirschmann, Michael T.
    ARTHROSKOPIE, 2021, 34 (05) : 342 - 350
  • [6] Patient-Specific Instrumentation in Total Knee Arthroplasty
    Jauregui, Julio J.
    Cherian, Jeffrey J.
    Kapadia, Bhaveen H.
    Banerjee, Samik
    Issa, Kimona
    Harwin, Steven F.
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2014, 27 (03) : 177 - 183
  • [7] Patient-specific instrumentation in total knee arthroplasty
    Leon-Munoz, Vicente J.
    Martinez-Martinez, Francisco
    Lopez-Lopez, Mirian
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (07) : 555 - 567
  • [8] Reliability of patient specific instrumentation in total knee arthroplasty
    Jennart, Harold
    Yamben, Marie-Ange Ngo
    Kyriakidis, Theofylaktos
    Zorman, David
    ACTA ORTHOPAEDICA BELGICA, 2015, 81 (04): : 668 - 672
  • [9] Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty
    Spencer-Gardner, L.
    Pierrepont, J.
    Topham, M.
    Bare, J.
    McMahon, S.
    Shimmin, A. J.
    BONE & JOINT JOURNAL, 2016, 98B (10): : 1342 - 1346
  • [10] Patient-specific instrumentation and custom total knee implants in total knee arthroplasty
    Isaacson, Mark
    Bunn, Kevin
    Incavo, Stephen
    CURRENT ORTHOPAEDIC PRACTICE, 2015, 26 (03): : 224 - 227