FIELD-TEST OF 275-KV INTERNALLY WATER COOLED XLPE CABLE SYSTEM

被引:0
|
作者
OGAWA, K
KURATA, M
SUZUKI, H
KAWASAKI, K
IMAI, N
NAKAMURA, S
SAKAI, S
机构
[1] CENT RES INST ELECT POWER IND,YOKOSUKA RES LAB,KANAGAWA,JAPAN
[2] MITSUBISHI CABLE IND LTD,ITAMI,JAPAN
关键词
D O I
10.1109/61.19182
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:8 / 18
页数:11
相关论文
共 50 条
  • [31] 275-KV SELF-CONTAINED OIL-FILLED CABLE INSULATED WITH POLYMETHYLPENTENE LAMINATED PAPER
    SAKURAI, T
    IWATA, Z
    SHIMIZU, M
    FUJISAKI, Y
    FURUSAWA, H
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (05): : 2575 - 2583
  • [32] IMPROVEMENT IN RELIABILITY OF EXTRUSION TYPE MOLDED JOINT FOR 275KV XLPE CABLE
    ISHIHARA, H
    SUZUKI, H
    SAKUMA, S
    BAN, S
    SHISEKI, N
    YAMAGUCHI, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (04) : 1735 - 1744
  • [33] OPERATION CONTROL OF INTERNALLY CONDUCTOR COOLED CABLE SYSTEM
    OGAWA, K
    KURATA, M
    SUZUKI, H
    OSAWA, S
    KATO, H
    ICHIYANAGI, N
    KAWASAKI, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (01) : 50 - 57
  • [34] DEVELOPMENT OF INTERNALLY OIL-COOLED CABLE SYSTEMS FIELD TRIALS OF 400KV INTERNALLY OIL-COOLED CABLES AND UK REQUIREMENTS AND FUTURE PROSPECTS FOR FORCED-COOLED CABLE SYSTEMS - DISCUSSION
    MASCHIO, G
    THELWELL, MJ
    LUONI, G
    BRAKELMANN, H
    SMEE, GJ
    SOULSBY, DR
    BOONE, W
    GREGORY, B
    WATKINS, RHW
    ARKELL, CA
    HUTSON, RB
    NICHOLSON, JA
    BROTHERTON, W
    FROST, RF
    SELVES, J
    BALL, EH
    ENDACOTT, JD
    SKIPPER, DJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1978, 125 (10): : 1021 - 1026
  • [35] EFFECTS OF IONIC SOLUTIONS TO WATER TREEING ON XLPE CABLE FOR 22 kV DISTRIBUTION SYSTEM
    Promvichai, Narupon
    Marungsri, Boonruang
    Boonraksa, Terapong
    SURANAREE JOURNAL OF SCIENCE AND TECHNOLOGY, 2018, 25 (04): : 363 - 372
  • [36] Artificial accelerated ageing test of 22 kV XLPE cable for distribution system applications in Thailand
    Rawangpai, A.
    Maraungsri, B.
    Chomnawang, N.
    World Academy of Science, Engineering and Technology, 2010, 65 : 220 - 225
  • [37] Artificial accelerated ageing test of 22 kV XLPE cable for distribution system applications in Thailand
    Rawangpai, A.
    Maraungsri, B.
    Chomnawang, N.
    World Academy of Science, Engineering and Technology, 2010, 41 : 220 - 225
  • [38] Development and evaluation of 400kV XLPE cable system
    Becker, J
    Chatterjee, S
    1996 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE PROCEEDINGS, 1996, : 508 - 514
  • [39] Monitoring of 420 kV XLPE Cable System in Underground Tunnel
    Gieselbrecht, D.
    Koltunowicz, W.
    Obralic, A.
    Ritz, T.
    Christensen, P.
    Schneider, B.
    Cohnen, K. H.
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 917 - 920
  • [40] Development of a 500-kV DC XLPE cable system
    Maruyama, Satoru
    Ishii, Noboru
    Shimada, Michihiro
    Kojima, Shinji
    Tanaka, Hideo
    Asano, Mitsumasa
    Yamanaka, Tetsuya
    Kawakami, Shin'ichi
    Furukawa Review, 2004, (25): : 47 - 52