CLEARANCE FROM DIALYSATE AND EQUILIBRATION OF INTRAPERITONEAL VANCOMYCIN IN CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS

被引:15
|
作者
NEAL, D
BAILIE, GR
机构
[1] ALBANY COLL PHARM,106 NEW SCOTLAND AVE,ALBANY,NY 12208
[2] UNIV MANCHESTER,DEPT PHARM,MANCHESTER M13 9PL,LANCS,ENGLAND
关键词
D O I
10.2165/00003088-199018060-00005
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This article reports on a study of the disposition of loading doses (1g and 15 mg/kg) of vancomycin given intraperitoneally to 6 patients on continuous ambulatory peritoneal dialysis with Gram-positive peritonitis. Dialysate samples were collected every 30 minutes during the first dwell, and serum samples were collected after the first 5 exchanges and after 7 or 14 days. The dialysate concentration/time data were fitted to a monoexponential curve for 4 patients and to a biexponential curve for 2 others. Dialysis clearance was 0.73 ± 0.04 L/h (1g dose) and 0.70 ± 0.23 L/h (15 mg/kg dose). Total body clearance was 0.51 ± 0.36 L/h. Serum concentrations reached 14 to 18 mg/L (15 mg/kg dose) and 6.75 to 24 mg/L (1g dose) at the end of the first dwell. The half-life of equilibration of vancomycin across the peritoneal membrane was 2.5 ± 2.3 hours. Intraperitoneal loading doses of vancomycin produce concomitant serum concentrations in excess of the minimum inhibitory concentrations for susceptible organisms. Administration on a milligram per kilogram basis produces more consistent serum concentrations than using a standard loading dose which is not based on bodyweight. © 1990, Adis Press Limited. All rights reserved.
引用
收藏
页码:485 / 490
页数:6
相关论文
共 50 条