MEASUREMENT OF BLOOD-FLOW INVIVO BY LASER DOPPLER ANEMOMETRY THROUGH A MICROSCOPE

被引:0
|
作者
EINAV, S [1 ]
BERMAN, HJ [1 ]
FUHRO, RL [1 ]
DIGIOVANNI, PR [1 ]
FRIDMAN, JD [1 ]
FINE, S [1 ]
机构
[1] BOSTON UNIV,DEPT BIOL,BOSTON,MA
关键词
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
引用
收藏
页码:203 / 205
页数:3
相关论文
共 50 条
  • [31] CONTINUOUS MEASUREMENT OF TISSUE BLOOD-FLOW BY LASER-DOPPLER SPECTROSCOPY
    STERN, MD
    LAPPE, DL
    BOWEN, PD
    CHIMOSKY, JE
    HOLLOWAY, GA
    KEISER, HR
    BOWMAN, RL
    AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 232 (04): : H441 - H448
  • [32] VELOCITY-MEASUREMENTS OF BLOOD-FLOW IN CAPILLARY AND VEIN USING A LASER DOPPLER MICROSCOPE
    MISHINA, H
    KOYAMA, T
    ASAKURA, T
    APPLIED OPTICS, 1975, 14 (10): : 2326 - 2327
  • [33] INVIVO EVALUATION OF DIFFERENT LASER DOPPLER SYSTEMS FOR QUANTITATIVE ESTIMATION OF TISSUE BLOOD-FLOW
    AHN, H
    JOHANSSON, K
    LUNDGREN, O
    NILSSON, GE
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 203 - 203
  • [34] BLOOD VELOCITY-MEASUREMENT BY FIBER OPTIC LASER DOPPLER ANEMOMETRY
    KILPATRICK, D
    TYBERG, JV
    PARMLEY, WW
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (02) : 142 - 145
  • [35] A LASER-DOPPLER INSTRUMENT FOR INVIVO MEASUREMENTS OF BLOOD-FLOW IN SINGLE RENAL ARTERIOLES
    SMEDLEY, G
    YIP, KP
    WAGNER, A
    DUBOVITSKY, S
    MARSH, DJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (03) : 290 - 297
  • [36] BLOOD-FLOW IN SINGLE RENAL ARTERIOLES MEASURED INVIVO WITH LASER-DOPPLER VELOCIMETRY
    YIP, KP
    SMEDLEY, GT
    MARSH, DJ
    FASEB JOURNAL, 1992, 6 (05): : A1812 - A1812
  • [37] Laser Doppler Anemometry as flow measurement method behind 90° bend
    Synowiec, Piotr
    Wedrychowicz, Wieslaw
    Piechota, Piotr
    Andruszkiewicz, Artur
    PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (11): : 90 - 92
  • [38] INVIVO MEASUREMENT OF BRAIN BLOOD-FLOW IN THE CAT
    PETROFSKY, JS
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (08) : 441 - 445
  • [39] Quantitative measurement of blood flow dynamics in chorioallantoic membrane of chicken embryo using laser Doppler anemometry
    Borozdova, M. A.
    Stiukhina, E. S.
    Sdobnov, A. Yu.
    Fedosov, I. V.
    Postnov, D. E.
    Tuchin, V. V.
    SARATOV FALL MEETING 2015 THIRD INTERNATIONAL SYMPOSIUM ON OPTICS AND BIOPHOTONICS; AND SEVENTH FINNISH-RUSSIAN PHOTONICS AND LASER SYMPOSIUM (PALS), 2016, 9917
  • [40] NONINVASIVE BLOOD-FLOW MEASUREMENT BY DOPPLER ULTRASOUND
    SKIDMORE, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (03): : 310 - 310