2,3-BUTANEDIOL IN PLASMA FROM AN ALCOHOLIC MISTAKENLY IDENTIFIED AS ETHYLENE-GLYCOL BY GAS-CHROMATOGRAPHIC ANALYSIS

被引:0
|
作者
JONES, AW
NILSSON, L
GLADH, SA
KARLSSON, K
BECKFRIIS, J
机构
[1] LINKOPING UNIV HOSP,DEPT CLIN CHEM,S-58185 LINKOPING,SWEDEN
[2] MOTALA HOSP,DEPT ANESTHESIOL,MOTALA,SWEDEN
关键词
TOXICOLOGY; 2-BUTANONE;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
2,3-Butanediol was mistakenly identified as ethylene glycol in plasma specimens from two alcoholic patients. The cyclic phenylboronate ester derivatives of 2,3-butanediol and ethylene glycol had the same retention time when OV-17 was used as the stationary phase for gas chromatography. This led to incorrect diagnosis of ethylene glycol poisoning and unnecessary invasive therapy. Plasma from two chronic alcoholics contained 2,3-butanediol at 3.5 and 3.4 mmol/L. The elimination half-life of 2,3-butanediol was 3.9 days when ethanol was administered during therapy for suspected ethylene glycol poisoning. Low concentrations of 2,3-butanediol might be present in blood of chronic alcoholics as a result of a novel pathway of intermediary metabolism associated with some forms of alcoholism. However, a more likely explanation for fairly high concentrations of 2,3-butanediol is enzymatic production from 2-butanone. This ketone occurs in denatured alcohol preparations often consumed by alcoholics in Sweden.
引用
收藏
页码:1453 / 1455
页数:3
相关论文
共 50 条
  • [41] Techno-economic analysis of various process schemes for the production of fuel grade 2,3-butanediol from fermentation broth
    Haider, Junaid
    Qyyum, Muhammad Abdul
    Hussain, Arif
    Yasin, Muhammad
    Lee, Moonyong
    BIOCHEMICAL ENGINEERING JOURNAL, 2018, 140 : 93 - 107
  • [42] OXYGENATED ORGANIC-COMPOUNDS FROM SYNTHESIS GAS - REVIEW .2. PRODUCTION OF ETHYLENE-GLYCOL FROM SYNTHESIS GAS VIA METHANOL OR FORMALDEHYDE
    NOWAK, S
    EICHHORN, I
    OHME, I
    LUCKE, B
    CHEMISCHE TECHNIK, 1984, 36 (04): : 144 - 147
  • [43] SIMULTANEOUS DETERMINATION OF ETHYLENE-GLYCOL, PROPYLENE-GLYCOL, 1,3-BUTYLENE GLYCOL AND 2,3-BUTYLENE GLYCOL IN HUMAN SERUM AND URINE BY WIDE-BORE COLUMN GAS-CHROMATOGRAPHY
    HOUZE, P
    CHAUSSARD, J
    HARRY, P
    PAYS, M
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (02): : 251 - 257
  • [44] GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF ENDOGENOUS LEVELS OF ESTRADIOL IN PLASMA AND IN CYTOSOL FROM RAT UTERUS
    TETSUO, M
    ERIKSSON, H
    SJOVALL, J
    JOURNAL OF CHROMATOGRAPHY, 1982, 239 (APR): : 287 - 300
  • [45] NOISE-ANALYSIS OF THE REFLECTED POWER SIGNAL FROM A MICROWAVE-INDUCED PLASMA GAS-CHROMATOGRAPHIC DETECTOR
    BOLAINEZ, RMA
    BOSS, CB
    ANALYTICA CHIMICA ACTA, 1992, 269 (01) : 89 - 97
  • [46] Metabolic engineering design to enhance (R,R)-2,3-butanediol production from glycerol in Bacillus subtilis based on flux balance analysis
    Nunthaphan Vikromvarasiri
    Tomokazu Shirai
    Akihiko Kondo
    Microbial Cell Factories, 20
  • [47] Metabolic engineering design to enhance (R,R)-2,3-butanediol production from glycerol in Bacillus subtilis based on flux balance analysis
    Vikromvarasiri, Nunthaphan
    Shirai, Tomokazu
    Kondo, Akihiko
    MICROBIAL CELL FACTORIES, 2021, 20 (01)
  • [48] Techno-Economic Analysis and Life Cycle Assessment for the Separation of 2,3-Butanediol from Fermentation Broth Using Liquid-Liquid Extraction
    Liu, Jian
    Kubic, William L.
    Tan, Eric C. D.
    Dempsey, Jacob W.
    Benavides, Pahola Thathiana
    Balchandani, Sweta
    Olcay, Hakan
    Liu, Dupeng
    Sun, Ning
    Dangwal, Shailesh
    Trusty, Blake N.
    Islam, Syed Z.
    Bhave, Ramesh R.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2025, 64 (10) : 5511 - 5521
  • [50] GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC COMPUTER-ANALYSIS OF VOLATILE COMPONENTS IN BLOOD-PLASMA FROM HEMODIALYSIS PATIENTS
    DOWTY, B
    CARLISLE, D
    LASETER, JL
    GONZALEZ, FM
    BIOMEDICAL MASS SPECTROMETRY, 1975, 2 (03): : 142 - 147