MRI;
MAGNETIZATION TRANSFER CONTRAST;
LIVER METASTASES;
D O I:
10.1016/0730-725X(94)92346-9
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
A method of performing magnetization transfer contrast (MTC) using a pulse sequence based on a series of on-resonance binomial pulses preceding a conventional spin-echo sequence has been recently described. We investigated this technique in the evaluation of circumscribed hepatic neoplasms on a 0.5 T imager. Conventional spin-echo imaging was performed in 18 patients with hepatic neoplasms, 15 with primary or metastatic hepatic neoplasms, and 3 with cavernous hemangiomas. The T-1-weighted sequence was repeated following MTC saturation in 7 patients and the proton density sequence was repeated following MTC saturation in 13 patients (both were used in two patients). The mean lesion-to-liver contrast for neoplasms worsened with T-1-MTC (0.87 vs. 1.04), but improved slightly with proton density-MTC (1.10 vs. 1.22) when compared to the corresponding non-MTC spin-echo images. However, these differences were not statistically significant (p =.19 and p =.16, respectively). The limited data on cavernous hemangiomas does not suggest these have consistently different MTC imaging characteristics from other hepatic neoplasms. In conclusion, MTC imaging using a binomial saturation pulse did not offer significant improvement in contrast between hepatic neoplasms and normal liver. Refinements of the binomial pulse sequence will be necessary if a consistent improvement in lesion sensitivity is to be achieved. Evaluation of its role in increasing diagnostic specificity will require further investigation.