Modified hybrid fixator for high-energy Schatzker V and VI tibial plateau fractures

被引:32
|
作者
Ariffin, Hisam Muhamad [1 ]
Mahdi, Nidzwani M. [1 ]
Rhani, Shaharuddin A. [1 ]
Baharudin, Azmi [1 ]
Shukur, Mohamad Hassan [1 ]
机构
[1] Univ Kebangsaan Malaysia Med Ctr, Fac Med, Kuala Lumpur, Malaysia
来源
关键词
High-energy tibial plateau fractures; Severe soft tissue injury; Hybrid external fixator;
D O I
10.1007/s11751-011-0105-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
High-energy tibial plateau fractures associated with severe soft tissue injury are difficult to manage. The risk of wound complications following open reduction and internal fixation is notably high owing to extensive soft tissue dissection. Alternatively, application of hybrid external fixator minimizes soft tissue dissection and provides adequate fracture stabilization to allow early range of motion and correction of any mal-alignment. With this technique, soft tissue complications particularly surgical site infections are expected to be significantly reduced. This prospective study aims to determine the effectiveness of a modified hybrid external fixator in the management of high-energy tibial plateau fractures. Thirty-three patients with high-energy Schatzker V and VI tibial plateau fracture with severe soft tissue injury precluding formal open reduction were enrolled into the study. The fixator was a construct combining the Ilizarov ring with a monolateral external fixator. The results-bony union, range of motion, and associated complications of the treatment-were assessed. All fractures united within an average time of 14 weeks. Neither loss of reduction nor surgical site wound breakdown/osteomyelitis was noted. Eight patients developed superficial pin track infection and one septic arthritis of the knee joint. Hybrid external fixation is a safe option for complex high-energy tibial plateau fractures by simultaneously providing adequate fracture stabilization and protection of soft tissue healing to achieve bony union. The complication is mainly related to pin tract infection.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [41] Maintenance of an Intraoperative External Fixator Is Associated With Decreased Postoperative Stiffness After Definitive Management of High-Energy Tibial Plateau Fractures
    Speybroeck, Jacob
    Moon, Tyler
    Haase, Lucas
    Haase, Douglas
    Wise, Brent
    Ochenjele, George
    Napora, Joshua
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [42] Management of high-energy tibial shaft fractures using the hexapod circular external fixator
    Yanshi Liu
    Jialin Liu
    Maimaiaili Yushan
    Zhenhui Liu
    Tao Zhang
    He Ma
    Chuang Ma
    Aihemaitijiang Yusufu
    BMC Surgery, 21
  • [43] Management of high-energy tibial shaft fractures using the hexapod circular external fixator
    Liu, Yanshi
    Liu, Jialin
    Yushan, Maimaiaili
    Liu, Zhenhui
    Zhang, Tao
    Ma, He
    Ma, Chuang
    Yusufu, Aihemaitijiang
    BMC SURGERY, 2021, 21 (01)
  • [44] Are Infection Rates Increased After Sterilization of the External Fixator During Staged Internal Fixation of High-Energy Tibial Plateau Fractures?
    Moon, Tyler James
    Haase, Lucas
    Haase, Douglas
    Ochenjele, George
    Wise, Brent
    Napora, Joshua
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2022, 36 (10) : 530 - 534
  • [45] High-energy open tibial fractures in children TREATMENT WITH A PROGRAMMABLE CIRCULAR EXTERNAL FIXATOR
    Monsell, F. P.
    Howells, N. R.
    Lawniczak, D.
    Jeffcote, B.
    Mitchell, S. R.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (07): : 989 - 993
  • [46] Classifications in Brief: Schatzker Classification of Tibial Plateau Fractures
    Zeltser, David W.
    Leopold, Seth S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (02) : 371 - 374
  • [47] High energy tibial plateau fractures treated with hybrid external fixation
    George C Babis
    Dimitrios S Evangelopoulos
    Panagiotis Kontovazenitis
    Konstantinos Nikolopoulos
    Panagiotis N Soucacos
    Journal of Orthopaedic Surgery and Research, 6
  • [48] High energy tibial plateau fractures treated with hybrid external fixation
    Babis, George C.
    Evangelopoulos, Dimitrios S.
    Kontovazenitis, Panagiotis
    Nikolopoulos, Konstantinos
    Soucacos, Panagiotis N.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2011, 6
  • [49] Arthroscopically assisted treatment for Schatzker type I-V tibial plateau fractures
    Duan Xiao-jun
    Yang Liu
    Guo Lin
    Chen Guang-xing
    Dai Gang
    CHINESE JOURNAL OF TRAUMATOLOGY, 2008, 11 (05) : 288 - 292
  • [50] Fracture characteristics and functional outcomes for Schatzker V/VI bicondylar tibial plateau fractures with a separate tubercle fragment: a comparative study
    Stenquist, Derek S.
    Caton, Tyler D.
    Chen, Eric Y.
    Selzer, Faith
    Harris, Mitchel B.
    Heng, Marilyn
    Weaver, Michael J.
    Von Keudell, Arvind G.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)