Modified hybrid fixator for high-energy Schatzker V and VI tibial plateau fractures

被引:32
|
作者
Ariffin, Hisam Muhamad [1 ]
Mahdi, Nidzwani M. [1 ]
Rhani, Shaharuddin A. [1 ]
Baharudin, Azmi [1 ]
Shukur, Mohamad Hassan [1 ]
机构
[1] Univ Kebangsaan Malaysia Med Ctr, Fac Med, Kuala Lumpur, Malaysia
来源
关键词
High-energy tibial plateau fractures; Severe soft tissue injury; Hybrid external fixator;
D O I
10.1007/s11751-011-0105-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
High-energy tibial plateau fractures associated with severe soft tissue injury are difficult to manage. The risk of wound complications following open reduction and internal fixation is notably high owing to extensive soft tissue dissection. Alternatively, application of hybrid external fixator minimizes soft tissue dissection and provides adequate fracture stabilization to allow early range of motion and correction of any mal-alignment. With this technique, soft tissue complications particularly surgical site infections are expected to be significantly reduced. This prospective study aims to determine the effectiveness of a modified hybrid external fixator in the management of high-energy tibial plateau fractures. Thirty-three patients with high-energy Schatzker V and VI tibial plateau fracture with severe soft tissue injury precluding formal open reduction were enrolled into the study. The fixator was a construct combining the Ilizarov ring with a monolateral external fixator. The results-bony union, range of motion, and associated complications of the treatment-were assessed. All fractures united within an average time of 14 weeks. Neither loss of reduction nor surgical site wound breakdown/osteomyelitis was noted. Eight patients developed superficial pin track infection and one septic arthritis of the knee joint. Hybrid external fixation is a safe option for complex high-energy tibial plateau fractures by simultaneously providing adequate fracture stabilization and protection of soft tissue healing to achieve bony union. The complication is mainly related to pin tract infection.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [1] Outcome of High-energy Tibial Plateau Schatzker Type VI Fractures with Compromised Soft Tissue Treated by Ilizarov Fixator
    Jana, Kanailal
    Chatterjee, Atanu
    Pujari, Prasanta Kumar
    Jha, Dipak Kumar
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (06) : 66 - 71
  • [2] Radiological and Functional Outcomes of Hybrid External Fixator Treated Schatzker Type V-Vi Tibial Plateau Fractures
    Amjad, Usman
    Sattar, Anum
    Khalid, Kiran Zarnab
    Shakoor, Muhammad Abdul
    Imtiaz, Waleed
    Shah, Syed Wasif Ali
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (09): : 2393 - 2395
  • [3] Illizarov Hybrid External Fixation for Schatzker V and VI Tibial Plateau Fractures
    Mughal, Naeem Mahmood
    Iqbal, Tariq
    Shahwani, Muhammad Bakhsh
    Dar, Usman Farooq
    Dar, Umar Farooq
    Imtiaz, Umar
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (02): : 495 - 497
  • [4] High-energy tibial plateau fractures treated with Ilizarov fixator
    Tomic, Slavko
    Baljozovic, Andreja
    Jeremic, Danilo
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2019, 147 (7-8) : 427 - 431
  • [5] Outcome of Schatzker type V and VI tibial plateau fractures
    Pun, Tul B.
    Krishnamoorthy, Vignesh P.
    Poonnoose, Pradeep M.
    Oommen, Anil T.
    Korula, Ravi J.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (01) : 35 - 41
  • [6] Outcome of Schatzker type V and VI tibial plateau fractures
    Tul B. Pun
    Vignesh P. Krishnamoorthy
    Pradeep M. Poonnoose
    Anil T. Oommen
    Ravi J. Korula
    Indian Journal of Orthopaedics, 2014, 48 : 35 - 41
  • [7] Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator
    Dendrinos, GK
    Kontos, S
    Katsenis, D
    Dalas, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05): : 710 - 717
  • [8] Result of Ring Fixator in High-energy Schatzker Type VI Fractures of Proximal Tibia
    Khanzada, Aftab Alam
    Joyo, Muhammad Rafique
    Javed, Muhammad Imran
    Ahmed, Nizam
    Keerio, Niaz Hussain
    Shah, Ghazanfar Ali
    Noor, Syed Shahid
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (43B) : 451 - 459
  • [9] HIGH-ENERGY FRACTURES OF THE TIBIAL PLATEAU
    WATSON, JT
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1994, 25 (04) : 723 - &
  • [10] High-energy tibial plateau fractures
    Berkson, EM
    Virkus, WW
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2006, 14 (01) : 20 - 31