INHALED NITRIC-OXIDE MONITORING

被引:0
|
作者
FAJARDO, CA
PROKOPOWICH, J
BELIK, J
机构
[1] UNIV MANITOBA,DEPT PEDIAT,WINNIPEG,MB R3T 2N2,CANADA
[2] MANITOBA DEPT ENVIRONM,WINNIPEG,MB,CANADA
[3] WORKPLACE SAFETY & HLTH,WINNIPEG,MB,CANADA
关键词
NITRIC OXIDE; MONITORING;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Recently, inhaled nitric oxide (NO) became clinically available for the treatment of persistent pulmonary hypertension of the newborn. Such use requires administration and continuous monitoring of a very low concentration of NO to prevent potential toxicity. Since limited data on the reliability of NO monitoring devices are available, we evaluated the performance of a chemiluminescent and electrochemical sensor NO analyzer in a patient ventilator circuit. Results: The chemiluminescence analyzer readings were significantly altered by the oxygen concentration in the ventilator circuit. When the FiO(2) was increased from 0.21 to 1, a 4.5% +/- 0.3 decrease in the NO readings was found (p < 0.01). Similarly, adding humidity to the circuit, reduced the NO readings by 4.8% +/- 0.9 (p < 0.01). The effect of gas pressure was proportional to its magnitude but independent of whether a pulsatile or continuous gas flow was provided. At a mean airway pressure of 15 cm H2O, the NO readings increased by 3.94% +/- 0.05 (NO = 10 parts per million) and 3.97% +/- 0.02 (40 parts per million) (p < 0.01). The electrochemical sensor NO readings were directly proportional to the ventilator circuit pressure but independent of whether a pulsatile or continuous gas flow was provided. At a mean airway pressure of 15 cm H2O, the NO reading was increased by 25.39% +/- 0.04 (NO = 40 parts per million) (p < 0.01) and 1.07% +/- 0.16 (NO = 10 parts per million) (p NS). The greatest difference with NO = 10 parts per million from baseline was found at a mean airway pressure of 6 cm H2O (6.67% +/- 0.23; p < 0.01). In conclusion, the measurement of NO by the chemiluminescence technique was influenced by humidity, oxygen concentration and ventilator circuit gas pressure. Yet the observed changes were small and of questionable clinical significance, making this technique reliable to monitor patients receiving inhaled NO. In regards to the electrochemical sensor, the marked effect of gas pressure upon the NO reading precision makes this device less suitable for NO monitoring in a patient ventilator circuit.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [21] DEVICE TO MONITOR CONCENTRATION OF INHALED NITRIC-OXIDE
    MERCIER, JC
    ZUPAN, V
    DEHAN, M
    RENAUDIN, MH
    BOUCHET, M
    RAVEAU, C
    LANCET, 1993, 342 (8868): : 431 - 432
  • [22] INHALED NITRIC-OXIDE AND INCREMENTAL EXERCISE PERFORMANCE
    MARKOWITZ, DH
    IMANAKA, H
    KACMAREK, RM
    PAPPAGIANOPOULOS, PP
    BOUCHER, CA
    COCKRILL, BA
    KANAREK, DJ
    SYSTROM, DM
    FASEB JOURNAL, 1995, 9 (03): : A359 - A359
  • [23] CONVERSION OF INHALED NITRIC-OXIDE TO NITRATE IN MAN
    WESTFELT, UN
    BENTHIN, G
    LUNDIN, S
    STENQVIST, O
    WENNMALM, A
    BRITISH JOURNAL OF PHARMACOLOGY, 1995, 114 (08) : 1621 - 1624
  • [24] METHEMOGLOBINEMIA AS A COMPLICATION OF INHALED NITRIC-OXIDE THERAPY
    BATES, J
    MURRAY, D
    BOLLEN, B
    ANESTHESIOLOGY, 1993, 79 (3A) : A231 - A231
  • [25] SELECTIVE PULMONARY VASODILATATION WITH INHALED NITRIC-OXIDE
    TONZ, M
    VONSEGESSER, LK
    TURINA, M
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 105 (04): : 760 - 762
  • [26] INHALED NITRIC-OXIDE - THE PAST, THE PRESENT, AND THE FUTURE
    PEARL, RG
    ANESTHESIOLOGY, 1993, 78 (03) : 413 - 416
  • [27] MINIDOSE INHALED NITRIC-OXIDE - LESS IS BETTER
    ZAPOL, WM
    INTENSIVE CARE MEDICINE, 1993, 19 (08) : 433 - 434
  • [28] Delivery and monitoring of inhaled nitric oxide
    Young, JD
    Dyar, OJ
    INTENSIVE CARE MEDICINE, 1996, 22 (01) : 77 - 86
  • [29] Inhaled Nitric Oxide Delivery and Monitoring
    Frederick J. Montgomery
    Anne D. Berssenbrugge
    Journal of Clinical Monitoring and Computing, 1999, 15 : 325 - 335
  • [30] Inhaled nitric oxide delivery and monitoring
    Montgomery, FJ
    Berssenbrugge, AD
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (05) : 325 - 335