WHICH INDEX OF PEAK EXPIRATORY FLOW IS MOST USEFUL IN THE MANAGEMENT OF STABLE ASTHMA

被引:109
|
作者
REDDEL, HK
SALOME, CM
PEAT, JK
WOOLCOCK, AJ
机构
[1] Institute of Respiratory Medicine, Royal Prince Alfred Hospital, Camperdown, NSW
[2] Department of Respiratory Medicine, Royal Prince Alfred Hospital, Camperdown, NSW 2050, Missenden Road
关键词
D O I
10.1164/ajrccm.151.5.7735580
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Calculation of diurnal peak expiratory flow (PEF) variability using values before and after bronchodilator is no longer possible for many asthmatic patients because they now use beta-agonists ''as needed'' for symptoms rather than regularly. This study assesses the usefulness of a number of alternative PEF indices as markers of airway lability in subjects with stable, although not necessarily well-controlled, asthma. Forty-six adult subjects completed a questionnaire about symptoms and treatment in the previous 3 mo. Spirometric function and airway hyperresponsiveness (AHR) were assessed; AHR was expressed as dose response ratio (DRR) (maximal percent fall in FEV(1) divided by final dose of histamine). Subjects recorded PEF morning and evening, before and after bronchodilator (if used) for 2 wk. Nine different PEF indices were calculated. Diurnal variability (amplitude percent maximum) without bronchodilator was significantly less than diurnal variability with bronchodilator. Normal indices of PEF lability were found in 42% of subjects with reduced maximal midexpiratory flow (MMEF). Most of the PEF indices correlated strongly with DRR, and less strongly with symptom score and airway obstruction. Minimum morning prebronchodilator PEF over a week (expressed as percent recent best or percent predicted) is recommended as the best PEF index of airway lability in patients with stable asthma because it correlates strongly with AHR, patients are more likely to comply with a once-daily reading, the calculation is simple, and regular use of a beta-agonist is not required.
引用
收藏
页码:1320 / 1325
页数:6
相关论文
共 50 条
  • [21] Serial peak expiratory flow measurement in the diagnosis of occupational asthma
    Gannon, PFG
    Burge, PS
    EUROPEAN RESPIRATORY JOURNAL, 1997, 10 : S57 - S63
  • [22] A practical guide for peak expiratory flow monitoring in asthma patients
    Jain, P
    Kavuru, MS
    CLEVELAND CLINIC JOURNAL OF MEDICINE, 1997, 64 (04) : 195 - +
  • [23] Annual Change of Peak Expiratory Flow Rate in Asthma and COPD
    Hong, Sung Chul
    Lee, Choi
    Han, Jang Soo
    Kim, Won Dong
    Lee, Kye Young
    Kim, Sun Jong
    Kim, Hee Joung
    Ha, Kyoung-Won
    Chon, Gyu Rak
    Yoo, Kwang Ha
    TUBERCULOSIS AND RESPIRATORY DISEASES, 2012, 72 (01) : 24 - 29
  • [24] Peak expiratory flow versus spirometry for diagnosis of asthma in adults
    Herrera Sanchez, D. A.
    O'farrill Romanillos, P. M.
    Segura Mendez, N. H.
    ALLERGY, 2019, 74 : 398 - 398
  • [25] PEAK EXPIRATORY FLOW-RATES IN POSSIBLE OCCUPATIONAL ASTHMA
    LISS, GM
    TARLO, SM
    CHEST, 1991, 100 (01) : 63 - 69
  • [26] PEAK EXPIRATORY FLOW-RATES IN POSSIBLE OCCUPATIONAL ASTHMA
    LISS, GM
    TARLO, SM
    CHEST, 1991, 100 (05) : 1480 - 1480
  • [27] ASTHMA SELF-MANAGEMENT EDUCATION-PROGRAM BY HOME MONITORING OF PEAK EXPIRATORY FLOW
    IGNACIOGARCIA, JM
    GONZALEZSANTOS, P
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (02) : 353 - 359
  • [28] Utility of peak expiratory flow home monitoring in children with asthma
    Gheonea, C.
    Dumitrescu, L.
    Bulucea, C.
    Constantinescu, A.
    ALLERGY, 2008, 63 : 175 - 175
  • [29] Assessment of diurnal variability of peak expiratory flow in stable asthmatics
    Aggarwal, AN
    Gupta, D
    Kumar, V
    Jindal, SK
    JOURNAL OF ASTHMA, 2002, 39 (06) : 487 - 491
  • [30] ADEQUACY OF CONTROL OF ASTHMA IN A GENERAL-PRACTICE - IS MAXIMUM PEAK EXPIRATORY FLOW-RATE A VALID INDEX OF ASTHMA SEVERITY
    MORRIS, NV
    ABRAMSON, MJ
    STRASSER, RP
    MEDICAL JOURNAL OF AUSTRALIA, 1994, 160 (02) : 68 - 71