PRESSURE DISTRIBUTION IN PERISTALTIC TRANSPORT OF FLUIDS WITH AN INSERTED CATHETER - A MODEL OF UROMETROGRAM

被引:0
|
作者
GOPALAN, NP [1 ]
DEVANATHAN, R [1 ]
机构
[1] INDIAN INST SCI,DEPT APPL MATH,BANGALORE 560012,KARNATAKA,INDIA
来源
INDIAN JOURNAL OF PURE & APPLIED MATHEMATICS | 1984年 / 15卷 / 06期
关键词
D O I
暂无
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
引用
收藏
页码:657 / 664
页数:8
相关论文
共 50 条
  • [31] PERISTALTIC TRANSPORT OF A CASSON FLUID IN A FINITE CHANNEL: APPLICATION TO FLOWS OF CONCENTRATED FLUIDS IN OESOPHAGUS
    Pandey, S. K.
    Tripathi, Dharmendra
    INTERNATIONAL JOURNAL OF BIOMATHEMATICS, 2010, 3 (04) : 453 - 472
  • [32] Developing an Alternative Workflow Model for Peripherally Inserted Central Catheter Placement
    Meyer, Britt M.
    JOURNAL OF INFUSION NURSING, 2012, 35 (01) : 34 - 42
  • [33] Peristaltic transport of Herschel–Bulkley fluids in tubes of variable cross section induced by dilating peristaltic waves: application to sliding hiatus hernia
    Pandey S.K.
    Singh A.
    Intl. J. Dyn. Cont., 2019, 2 (407-418): : 407 - 418
  • [34] Peristaltic transport of blood in small vessels: Study of a mathematical model
    Misra, JC
    Pandey, SK
    COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2002, 43 (8-9) : 1183 - 1193
  • [35] Peristaltic Transport of a Hyperbolic Tangent Fluid Model in an Asymmetric Channel
    Nadeem, Sohail
    Akram, Safia
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 2009, 64 (9-10): : 559 - 567
  • [36] PERISTALTIC TRANSPORT OF A 2-LAYERED MODEL OF PHYSIOLOGICAL FLUID
    SRIVASTAVA, LM
    SRIVASTAVA, VP
    JOURNAL OF BIOMECHANICS, 1982, 15 (04) : 257 - 265
  • [37] Model and comparative study for peristaltic transport of water based nanofluids
    Shehzad, S. A.
    Abbasi, F. M.
    Hayat, T.
    Alsaadi, Fuad
    JOURNAL OF MOLECULAR LIQUIDS, 2015, 209 : 723 - 728
  • [38] Development of Peristaltic Transfer System to Transport Feces in Space: Proposal of Driving Method Using Pressure Difference in Peristaltic Pump
    Uzawa, Shogo
    Kumamoto, Hiroya
    Yamazaki, Chiaki
    Okui, Manabu
    Nakamura, Taro
    IEEE ACCESS, 2022, 10 : 128399 - 128407
  • [39] A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study
    Jun Maki
    Makoto Sumie
    Tomoko Ide
    Masako Nagamatsu
    Katsuyuki Matsushita
    Kazuhiro Shirozu
    Midoriko Higashi
    Ken Yamaura
    BMC Anesthesiology, 22
  • [40] An in vitro study comparing a peripherally inserted central catheter to a conventional central venous catheter: no difference in static and dynamic pressure transmission
    Heath E Latham
    Timothy T Dwyer
    Bethene L Gregg
    Steven Q Simpson
    BMC Anesthesiology, 10