Ethylene Oxide: Acute Four-Hour and One-Hour Inhalation Toxicity Testing in Rats

被引:1
|
作者
Snellings, William M. [1 ]
Nachreiner, Donald J. [2 ]
Pottenger, Lynn H. [3 ]
机构
[1] Snellings Toxicol Consulting LLC, 23 Trails End Lane, Ridgefield, CT 06877 USA
[2] Bushy Run Res Ctr, Inhalat Dept, Export, PA 15632 USA
[3] Dow Chem Co USA, Toxicol & Environm Res & Consulting, Midland, MI 48674 USA
关键词
D O I
10.1155/2011/910180
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Ethylene oxide was tested on groups of rats for either 4-hour or 1-hour inhalation exposure, followed by 14 days of observation. Groups of five Sprague-Dawley rats/sex were exposed, and clinical signs and mortality were recorded. Clinical signs noted included irregular breathing, absence of certain reflexes, and tremors. Rats that died had moderate to severe pulmonary congestion. The calculated LC50 values, reported as ppm by volume (with 95% confidence limits), were as follows. 4-hour LC50 values were 1972 (1887 to 2061) ppm for males; 1537 (1391 to 1698) ppm for females; 1741 (1655 to 1831) ppm for the combined sexes. The 1-hour LC50 values were 5748 (5276 to 6262) ppm for males; 4439 (4034 to 4884) ppm for females; 5029 (4634 to 5459) ppm for the combined sexes.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] ACUTE AND 2-WEEK INHALATION TOXICITY STUDIES ON AEROSOLS OF SELECTED ETHYLENE-OXIDE PROPYLENE-OXIDE POLYMERS IN RATS
    KLONNE, DR
    NACHREINER, DJ
    DODD, DE
    LOSCO, PE
    TYLER, TR
    FUNDAMENTAL AND APPLIED TOXICOLOGY, 1987, 9 (04): : 773 - 784
  • [22] SUBCHRONIC (13-WEEK) INHALATION TOXICITY STUDY OF FORMALDEHYDE IN MALE-RATS - 8-HOUR INTERMITTENT VERSUS 8-HOUR CONTINUOUS EXPOSURES
    WILMER, JWGM
    WOUTERSEN, RA
    APPELMAN, LM
    LEEMAN, WR
    FERON, VJ
    TOXICOLOGY LETTERS, 1989, 47 (03) : 287 - 293
  • [23] SUBACUTE (4-WEEK) INHALATION TOXICITY STUDY OF FORMALDEHYDE IN MALE-RATS - 8-HOUR INTERMITTENT VERSUS 8-HOUR CONTINUOUS EXPOSURES
    WILMER, JWGM
    WOUTERSEN, RA
    APPELMAN, LM
    LEEMAN, WR
    FERON, VJ
    JOURNAL OF APPLIED TOXICOLOGY, 1987, 7 (01) : 15 - 16
  • [25] One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin
    Jaeger, Cedric
    Wildi, Karin
    Twerenbold, Raphael
    Reichlin, Tobias
    Gimenez, Maria Rubini
    Neuhaus, Jean-Daniel
    Grimm, Karin
    Boeddinghaus, Jasper
    Hillinger, Petra
    Nestelberger, Thomas
    Singeisen, Helene
    Gugala, Mathias
    Pretre, Gil
    Puelacher, Christian
    Wagener, Max
    Honegger, Ursina
    Schumacher, Carmela
    Weidmann, Zoraida Moreno
    Kreutzinger, Philipp
    Krivoshei, Lian
    Freese, Michael
    Stelzig, Claudia
    Dietsche, Sebastian
    Ernst, Susanne
    Rentsch, Katharina
    Osswald, Stefan
    Mueller, Christian
    AMERICAN HEART JOURNAL, 2016, 171 (01) : 92 - 102
  • [26] One-Hour Rule-out and Rule-in of Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin T
    Reichlin, Tobias
    Schindler, Christian
    Drexler, Beatrice
    Twerenbold, Raphael
    Reiter, Miriam
    Zellweger, Christa
    Moehring, Berit
    Ziller, Ronny
    Hoeller, Rebeca
    Gimenez, Maria Rubini
    Haaf, Philip
    Potocki, Mihael
    Wildi, Karin
    Balmelli, Cathrin
    Freese, Michael
    Stelzig, Claudia
    Freidank, Heike
    Osswald, Stefan
    Mueller, Christian
    ARCHIVES OF INTERNAL MEDICINE, 2012, 172 (16) : 1211 - 1218
  • [27] One-hour rule-out and rule-in of acute myocardial infarction using siemens sensitive cardiac Troponin I ultra
    Twerenbold, R.
    Meller, B.
    Rubini, M.
    Wildi, K.
    Mueller, M.
    Reichlin, T.
    Osswald, S.
    Mueller, C.
    EUROPEAN HEART JOURNAL, 2013, 34 : 74 - 74
  • [28] Pre-hospital One-Hour Troponin in a Low-Prevalence Population of Acute Coronary Syndrome: OUT-ACS study
    Johannessen, Tonje R.
    Vallersnes, Odd Martin
    Halvorsen, Sigrun
    Larstorp, Anne Cecilie K.
    Mdala, Ibrahimu
    Atar, Dan
    OPEN HEART, 2020, 7 (02):
  • [29] One-hour algorithm for early rule-out and rule-in of acute myocardial infarction using sensitive cardiac troponin i
    Gimenez, M. Rubini
    Twerenbold, R.
    Reichlin, T.
    Meller, B.
    Moehring, B.
    Haaf, P.
    Sou, S.
    Zellweger, C.
    Osswald, S.
    Mueller, C.
    EUROPEAN HEART JOURNAL, 2013, 34 : 240 - 240
  • [30] One-hour Rule-in and Rule-out of Acute Myocardial Infarction Using High-sensitivity Cardiac Troponin I
    Rubini Gimenez, Maria
    Twerenbold, Raphael
    Jaeger, Cedric
    Schindler, Christian
    Puelacher, Christian
    Wildi, Karin
    Reichlin, Tobias
    Haaf, Philip
    Merk, Salome
    Honegger, Ursina
    Wagener, Max
    Druey, Sophie
    Schumacher, Carmela
    Krivoshei, Lian
    Hillinger, Petra
    Herrmann, Thomas
    Campodarve, Isabel
    Rentsch, Katharina
    Bassetti, Stefano
    Osswald, Stefan
    Mueller, Christian
    AMERICAN JOURNAL OF MEDICINE, 2015, 128 (08): : 861 - +