Stability of a new, multichannel, low-level liquid scintillation counter system, Kvartett

被引:3
|
作者
Einarsson, S [1 ]
Theodorsson, P [1 ]
机构
[1] UNIV ICELAND,INST SCI,IS-107 REYKJAVIK,ICELAND
关键词
D O I
10.1017/S003382220003126X
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Kvartett is a new liquid scintillation counting (LSC) system for radiocarbon dating that takes a radical departure from conventional systems to obtain a compact, low-level counting system measuring four samples simultaneously. Each sample vial, inside the well of a large NaI(Tl) guard-counter crystal (facing down), sits on top of a vertical PMT, The fourfold counting capacity can be used to increase the number of samples being dated or to get higher precision. The increased throughput helps to keep a rigid quality-control standard. We monitored the background count rate almost continuously for 7 months, and measured the count rate of a standard repeatedly for 2 months. The results show the background and system reproducibility to be stable.
引用
收藏
页码:727 / 736
页数:10
相关论文
共 50 条
  • [41] URANIUM RADIOACTIVITY MEASUREMENT FOR LOW-LEVEL WASTEWATER BASED ON ULTRA-LOW LEVEL LIQUID SCINTILLATION ANALYZER
    Lv, Jinxu
    Lv, Ning
    Guo, Huiping
    Hu, Zeting
    Song, Geng
    Cai, Yinying
    Zhang, Heling
    Li, Daji
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE2020), VOL 2, 2020,
  • [42] A compact automatic low-level liquid scintillation system for radon-in water measurement by pulse pair counting
    Gudjonsson, GI
    Theodorsson, P
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 377 - 380
  • [43] TRITIUM MEASUREMENTS WITH A NEW LIQUID SCINTILLATION COUNTER
    NOAKES, JE
    NEARY, MP
    SPAULDING, JD
    NUCLEAR INSTRUMENTS & METHODS, 1973, 109 (01): : 177 - 187
  • [44] PREPARATION OF LOW-LEVEL RADIOACTIVE LIQUID SCINTILLATION WASTE FOR RELEASE INTO SANITARY SEWERAGE SYSTEMS
    GOOD, GR
    SELIKSON, MH
    HEALTH PHYSICS, 1983, 45 (01): : 203 - 203
  • [45] TEFLON VIALS FOR LOW-LEVEL C-14 LIQUID SCINTILLATION-COUNTING
    YANG, IC
    EMERSON, RL
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (01): : 20 - 20
  • [46] NEW LOW-LEVEL LUMINANCE PROCESSING SYSTEM
    BINGHAM, JP
    NORMAN, MN
    SHANLEY, RL
    YORKANIS, B
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1976, 22 (02) : 135 - 148
  • [47] LOW-LEVEL COUNTING BY LIQUID SCINTILLATION .I. TRITIUM MEASUREMENT IN HOMOGENEOUS SYSTEMS
    MOGHISSI, AA
    KELLEY, HL
    REGNIER, JE
    CARTER, MW
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1969, 20 (03): : 145 - &
  • [48] Preparation of background samples for accurate low-level measurements by liquid-scintillation spectrometry
    Kato, T
    Saito, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 524 (1-3): : 208 - 214
  • [49] LOW-LEVEL COUNTING BY LIQUID SCINTILLATION .2. APPLICATIONS OF EMULSIONS IN TRITIUM COUNTING
    LIEBERMAN, R
    MOGHISSI, AA
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1970, 21 (06): : 319 - +
  • [50] MEASUREMENT BY ULTRA LOW-LEVEL LIQUID SCINTILLATION-COUNTING FOLLOWING THE CHERNOBYL ACCIDENT
    SCHONHOFER, F
    WEISZ, J
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 115 (01): : 125 - 140