ELECTROTHERMAL VAPORIZATION FOR SAMPLE INTRODUCTION INTO ICP

被引:0
|
作者
KAWAGUCHI, H
ZHAN, GY
MIZUIKE, A
机构
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:972 / 976
页数:5
相关论文
共 50 条
  • [21] Peak broadening from an electrothermal vaporization sample introduction source into an inductively coupled plasma
    Venable, J
    Holcombe, JA
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (08) : 1431 - 1440
  • [22] DIODE LASER THERMAL VAPORIZATION - NOVEL SAMPLE INTRODUCTION TECHNIQUE FOR ICP MS
    Bednarik, Antonin
    Foltynova, Pavla
    Tomalova, Iva
    Kanicky, Viktor
    Preisler, Jan
    CECE 2014: 11TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS, 2014, : 80 - 83
  • [23] ELECTROTHERMAL VAPORIZATION FOR SAMPLE INTRODUCTION IN MICROWAVE-INDUCED PLASMA-ATOMIC ABSORPTION SPECTROMETRY
    DUAN, YX
    LI, XY
    JIN, QH
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (08) : 1091 - 1096
  • [24] Simultaneous electrothermal vaporization and nebulizer sample introduction system for inductively coupled plasma mass spectrometry
    Arnquist, Isaac J.
    Kreschollek, Thomas E.
    Holcombe, James A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (3-4) : 255 - 260
  • [25] ELECTROTHERMAL VAPORIZATION FOR SAMPLE INTRODUCTION INTO A 3-ELECTRODE DIRECT-CURRENT ARGON PLASMA
    ELLIOTT, WG
    MATUSIEWICZ, H
    BARNES, RM
    ANALYTICAL CHEMISTRY, 1986, 58 (06) : 1264 - 1265
  • [26] THE BENEFITS OF ELECTROTHERMAL VAPORIZATION FOR MINIMIZING INTERFERENCES IN ICP-MS
    BERES, S
    THOMAS, R
    DENOYER, E
    BRUCKNER, P
    SPECTROSCOPY, 1994, 9 (01) : 20 - 26
  • [27] DC arc vaporization as a sample introduction technique for analysis of solids by ICP-OES
    Rusak, DA
    Litteral, RL
    Smith, BW
    Winefordner, JD
    TALANTA, 1997, 44 (11) : 1987 - 1993
  • [28] DETERMINATION OF TRACE AMOUNTS OF RARE-EARTH AND OTHER ELEMENTS IN RICE SAMPLES BY ICP-AES WITH SAMPLE INTRODUCTION BY TUNGSTEN-COIL ELECTROTHERMAL VAPORIZATION
    MEI, EW
    JIANG, ZC
    LIAO, ZH
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 344 (1-2): : 54 - 58
  • [29] MODIFICATION OF A COMMERCIAL DIRECT-READING INDUCTIVELY COUPLED PLASMA SPECTROMETER FOR SAMPLE INTRODUCTION BY ELECTROTHERMAL VAPORIZATION
    TIKKANEN, MW
    NIEMCZYK, TM
    ANALYTICAL CHEMISTRY, 1984, 56 (11) : 1997 - 2000
  • [30] Closed-system trapping method for the direct determination of transport efficiency in electrothermal vaporization sample introduction
    Rybak, Michael E.
    Salin, Eric D.
    1600, Royal Soc of Chemistry, Cambridge, United Kingdom (15):