ERRORS IN FREQUENCY PARAMETERS OF EMG POWER SPECTRA

被引:36
|
作者
HOF, AL
机构
[1] University of Groningen, Laboratory of Medical Physics
关键词
D O I
10.1109/10.99071
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Frequency shifts in random signals, e.g., EMG or Doppler ultrasound, can be followed by monitoring one or more parameters of the power spectrum. When such a frequency parameter is determined over a finite length of the signal, a random error and sometimes a systematic error or bias are introduced. Approximate expressions, in terms of moments of the power spectrum, have been derived for bias and standard deviation of the estimates for mean frequency, zero-crossing frequency, and fractile frequency (of which the median frequency is a special case). Experimental results from surface EMG recordings of three human muscles in constant force isometric contractions were in agreement with the theoretical predictions. In this case the mean frequency had the smallest random error. It turned out that the measured values of the zero-crossing frequency can deviate considerably from the predictions by the Rice formula [10] when the amplitude distribution is not exactly Gaussian. In the presence of noise, all frequency parameters show a systematic deviation, depending on the signal-to-noise ratio. In addition to known results on this deviation for mean and zero-crossing frequency, an exact and an approximate expression for the fractile frequency are given. In the case of EMG plus wide-band white noise, the median frequency has the best immunity to noise.
引用
收藏
页码:1077 / 1088
页数:12
相关论文
共 50 条
  • [21] EMG mean power frequency determination using wavelet analysis
    Ranniger, CU
    Akin, DL
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 1589 - 1592
  • [22] Modulation of EMG power spectrum frequency during motor imagery
    Lebon, F.
    Rouffet, D.
    Collet, C.
    Guillot, A.
    NEUROSCIENCE LETTERS, 2008, 435 (03) : 181 - 185
  • [23] VARIABILITY OF THE EMG MEAN POWER FREQUENCY - A STUDY ON THE TRAPEZIUS MUSCLE
    OBERG, T
    SANDSJO, L
    KADEFORS, R
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1991, 1 (04) : 237 - 243
  • [24] Selection of structural parameters for correcting frequency random errors
    Song, DT
    Chen, SH
    Li, XN
    COMPUTERS & STRUCTURES, 1997, 62 (02) : 221 - 226
  • [25] EFFECT OF COUNTING ERRORS ON PARAMETERS OF GAMMA-RESONANCE SPECTRA
    KARAKISHEV, SD
    BALDOKHIN, YV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1988, 31 (05) : 1142 - 1146
  • [26] Correction Of Errors In Instruments Of Measuring Electric Power Parameters
    Karasinskiy O.L.
    Tesyk Y.F.
    Technical Electrodynamics, 2021, 2021 (02): : 84 - 90
  • [27] EMG POWER SPECTRA FREQUENCIES ASSOCIATED WITH VARIOUS MOTOR UNIT RECRUITMENT STRATEGIES
    SOLOMONOW, M
    BATEN, C
    SMIT, J
    BARATTA, R
    HERMENS, H
    SHOJI, H
    DAMBROSIA, R
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1026 - 1026
  • [28] SHIFTS IN EMG POWER SPECTRA OF HEAD MUSCLES DURING SUSTAINED VOLUNTARY CONTRACTIONS
    VANBOXTEL, A
    GOUDSWAARD, P
    VANDERMOLEN, GM
    VANDENBOSCH, WEJ
    BIOLOGICAL PSYCHOLOGY, 1980, 11 (3-4) : 279 - 279
  • [29] EMG POWER SPECTRA OF ELBOW EXTENSORS DURING RAMP AND STEP ISOMETRIC CONTRACTIONS
    BILODEAU, M
    ARSENAULT, AB
    GRAVEL, D
    BOURBONNAIS, D
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1991, 63 (01): : 24 - 28
  • [30] INVESTIGATIONS OF ERRORS IN SAMPLE AUTOCOVARIANCE FUNCTIONS AND THEIR CORRESPONDING POWER SPECTRA
    ARMSTRONG, SA
    GOUGH, PT
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (05) : 568 - 572