SCREENING FOR SLIGHT ALBUMINURIA - A COMPARISON OF SELECTED COMMERCIALLY AVAILABLE METHODS

被引:4
|
作者
WILLIAMS, BT
KETCHUM, CH
ROBINSON, CA
BELL, DSH
机构
[1] UNIV ALABAMA,DEPT PATHOL,RES & DEV LAB,UNIV STN,BIRMINGHAM,AL 35294
[2] UNIV ALABAMA,DEPT MED,BIRMINGHAM,AL 35294
关键词
D O I
10.1097/00007611-199012000-00018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Slight albuminuria predicts clinically significant nephropathy in patients with insulin-dependent diabetes mellitus (IDDM) and early death in patients with non-insulin-dependent diabetes mellitus (NIDDM). This study compares four commercially available methods for measuring low concentrations of urinary albumin. We tested random spot urine specimens from 50 nondiabetic volunteers and 100 diabetic patients. This specimen was chosen to simplify collection in an outpatient setting. Two screening methods were evaluated for their ability to detect urinary albumin in the range of 15 to 200 mg/L. Sensitivity and specificity were 100% and 54.7%, respectively, for the Ames Micro-Bumintest; and 95.5% and 91.5%, respectively, for the Sclavo Albumin Screen. The high number of false-positive results made the Micro-Bumintest unacceptable. The Albumin Screen yielded fewer false-positive results, but also produced some false-negatives. Two quantitative methods, a radioimmunoassay (RIA) and a turbidimetric assay (the SPQ Microalbumin), yielded results that agreed well with each other.
引用
下载
收藏
页码:1447 / 1449
页数:3
相关论文
共 50 条
  • [41] A COMPARISON OF COMMERCIALLY AVAILABLE MOLD SURVEY SERVICES
    ROGERS, SA
    ANNALS OF ALLERGY, 1983, 50 (01): : 37 - 40
  • [42] Evaluating MLPA for use in diagnostic telomere screening: A comparison with commercially available FISH kits.
    Massie, D
    Clark, C
    Grant, F
    Goldie, B
    Gallagher, L
    Couzin, D
    Dean, JCS
    JOURNAL OF MEDICAL GENETICS, 2005, 42 : S75 - S75
  • [43] Validity and reliability of selected commercially available metabolic analyzer systems
    Hodges, LD
    Brodie, DA
    Bromley, PD
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2005, 15 (05) : 271 - 279
  • [44] Screening evaluation of the quality of commercially available cigars, cigarillos, and bidis based on emission levels of selected terpenes and terpenoids
    Marc, Mariusz
    Bednarska, Sylwia
    Hac, Pawe
    Konieczka, Piotr
    MICROCHEMICAL JOURNAL, 2024, 205
  • [45] Anti-Ma/anti-Ta reactivity: A comparison of commercially available detection methods
    Johannis, W
    Hoffmann, LA
    Jarius, S
    Malchau, G
    Wielckens, K
    Voltz, R
    JOURNAL OF NEUROIMMUNOLOGY, 2006, 174 (1-2) : 201 - 202
  • [46] COMPARISON OF DIGOXIN VALUES OBTAINED USING SEVERAL COMMERCIALLY AVAILABLE TRITIATED AND IODINATED DIGOXIN METHODS
    SOTO, AR
    BROTHERTON, M
    CASTELLANOS, ME
    CHAMBLISS, KW
    CLINICAL CHEMISTRY, 1975, 21 (07) : 966 - 966
  • [47] COMPARISON OF A COMMERCIALLY AVAILABLE ASSAY SYSTEM WITH 2 REFERENCE METHODS FOR THE DETERMINATION OF PLASMA CHOLINESTERASE VARIANTS
    WHITTAKER, M
    BRITTEN, JJ
    DAWSON, PJG
    CLINICAL CHEMISTRY, 1983, 29 (10) : 1746 - 1751
  • [48] COMPARISON OF SERUM IMMUNOGLOBULIN VALUES OBTAINED USING SEVERAL COMMERCIALLY AVAILABLE RADIAL IMMUNODIFFUSION METHODS
    CASTELLANOS, ME
    CHAMBLISS, KW
    SOTO, AR
    CLINICAL CHEMISTRY, 1975, 21 (07) : 943 - 943
  • [49] Quantitative comparison of the Vitros® immunodiagnostic products folate assay with other commercially available methods.
    Boyer, BP
    Edgar, H
    Standley, J
    Haines, C
    Watson, C
    CLINICAL CHEMISTRY, 2002, 48 (06) : A71 - A71
  • [50] Evaluation of Two Commercially Available Glycated Hemoglobin Methods
    Gomez Pazmino, Betty J.
    Vera Lorenti, Fanny E.
    Guadalupe Vargas, Mariana E.
    Alvarez Condo, Graciela M.
    Veron, Dolores
    Cercado, Alicia G.
    Rodas Neira, Edgar I.
    Bahar, Burak
    Veron, Delma
    DIABETES, 2019, 68