Development of an Animal Fracture Model for Evaluation of Cement Augmentation Femoroplasty: An In Vitro Biomechanical Study

被引:2
|
作者
Luo, Qiang [1 ]
Lu, William W. [1 ]
Lau, Tak-Wing [1 ]
Leung, Frankie [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Orthopaed & Traumatol, Hong Kong, Hong Kong, Peoples R China
[2] Univ Hong Kong, Shenzhen Hosp, Shenzhen Key Lab Innovat Technol Orthopaed Trauma, Shenzhen, Peoples R China
来源
BIORESEARCH OPEN ACCESS | 2014年 / 3卷 / 02期
关键词
aging; femur fracture; hip fracture; osteoporosis;
D O I
10.1089/biores.2013.0036
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Osteoporotic hip fracture is the most severe kind of fracture with high morbidity and mortality. Patients' ambulation and quality of life are significantly affected by the fracture because only 50% regain their prefracture functional status, even if they undergo surgeries. There are many issues associated with the current preventive methods e.g., cost, side effects, patient compliance, and time for onset of action. Femoroplasty, the injection of bone cement into the proximal femur to augment femoral strength and to prevent fracture, has been an option with great potential. However, until now femoroplasty has remained at the stage of biomechanical testing. No in vivo study has evaluated its safety and effectiveness; there is not even an animal model for such investigations. The objective of this study was to develop a proximal femur fracture goat model that consistently fractures at the proximal femur when subject to vertical load, simulating osteoporotic hip fractures in human. Six pairs of fresh frozen mature Chinese goats' femora were obtained and randomly assigned into two groups. For the experimental group, a cylindrical bone defect was created at the proximal femur, while the control was left untreated. In addition, a configuration to mimic the mechanical axis of the goat femur was developed. When subjected to load along the mechanical axis, all the specimens from the bone defect group experienced femoral neck fractures, while fractures occurred at the femoral neck or other sites of the proximal femur in the control group. The biomechanical property (failure load) of the bone defect specimens was significantly lower than that of the control specimens (p < 0.05). Osteoporotic hip fractures of humans were simulated by a goat fracture model, which may serve as a reference for future femoroplasty studies in vivo. The newly developed configuration simulating a femoral mechanical axis for biomechanical tests was practicable during the study.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 50 条
  • [31] Biomechanical evaluation of biomaterial implants in large animal model: A review
    Kahar, Nik Nur Farisha Nik Md Noordin
    Jaafar, Mariatti
    Ahmad, Nurazreena
    Sulaiman, Abdul Razak
    Yahaya, Badrul Hisham
    Hamid, Zuratul Ain Abdul
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 3031 - 3035
  • [32] Evaluation of an Injectable Biphasic Calcium Sulfate/Hydroxyapatite Cement for the Augmentation of Fenestrated Pedicle Screws in Osteoporotic Vertebrae: A Biomechanical Cadaver Study
    Tian, Xinggui
    Raina, Deepak B. B.
    Vater, Corina
    Kilian, David
    Ahlfeld, Tilman
    Platzek, Ivan
    Nimtschke, Ute
    Taegil, Magnus
    Lidgren, Lars
    Thomas, Alexander
    Platz, Uwe
    Schaser, Klaus-Dieter
    Disch, Alexander C. C.
    Zwingenberger, Stefan
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2022, 13 (04)
  • [33] Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study
    Lodde, Moritz F.
    Katthagen, J. Christoph
    Schopper, Clemens O.
    Zderic, Ivan
    Richards, R. Geoff
    Gueorguiev, Boyko
    Raschke, Michael J.
    Hartensuer, Rene
    MEDICINA-LITHUANIA, 2021, 57 (12):
  • [34] Minimum cement volume required in vertebral body augmentation-A biomechanical study comparing the permanent SpineJack device and balloon kyphoplasty in traumatic fracture
    Rotter, Robert
    Schmitt, Lena
    Gierer, Philip
    Schmitz, Klaus-Peter
    Noriega, David
    Mittlmeier, Thomas
    Meeder, Peter-J.
    Martin, Heiner
    CLINICAL BIOMECHANICS, 2015, 30 (07) : 720 - 725
  • [35] Biomechanical in vitro evaluation of a ready-to-use calcium phosphate cement implanted to augment intramedullary nail fixation of a three-part humeral head fracture model
    Gruenewald, Dag
    Langenmair, Elia
    Hirschmueller, Anja
    Maier, Dirk
    Suedkamp, Norbert P.
    Konstantinidis, Lukas
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (07) : 706 - 711
  • [36] Development of an In Vitro Swan Neck Deformity Biomechanical Model
    Haddara, Mohammad M.
    Fan, Stacy
    Matache, Bogdan A.
    Chinchalkar, Shrikant J.
    Ferreira, Louis M.
    Suh, Nina
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2022, 17 (05): : 833 - 838
  • [37] Development of a scoliotic spine model for biomechanical in vitro studies
    Wilke, Hans-Joachim
    Mathes, Barbara
    Midderhoff, Stefan
    Graf, Nicolas
    CLINICAL BIOMECHANICS, 2015, 30 (02) : 182 - 187
  • [38] A New Method of Partial Screw Augmentation in Sheep Vertebrae In Vitro Biomechanical and Interfacial Evaluation
    Liu, Da
    Wu, Zi-xiang
    Gao, Ming-xuan
    Wan, Shi-yong
    Shi, Lei
    Fu, Suo-chao
    Wang, Jun
    Lei, Wei
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (05): : 318 - 324
  • [39] In vitro simulation of intraoperative vertebroplasty applied for pedicle screw augmentation. A biomechanical evaluation
    Zapalowicz, Krzysztof
    Kierzkowska, Agnieszka
    Ciupik, Lechoslaw F.
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2018, 52 (01) : 64 - 69
  • [40] Effect of Polymethylmethacrylate Augmentation on Cervical Stability after ACIF: In Vitro Biomechanical Study
    Chen, Chun
    Zhao, Weidong
    Sun, Peidong
    Zheng, Wei
    Wu, Changfu
    Qu, Dongbin
    Ouyang, Jun
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1860 - 1862