IOMEPROL VERSUS IOPAMIDOL IN CONTRAST-ENHANCED COMPUTED-TOMOGRAPHY OF THORACIC AND ABDOMINAL ORGANS

被引:5
|
作者
VALENTINI, AL
TARTAGLIONE, T
MONTI, L
MARANO, P
机构
[1] Institute for Radiological Sciences, 'Sacro Cuore' Catholic University, 00100 Rome
关键词
COMPUTED TOMOGRAPHY; CONTRAST MEDIA; COMPARATIVE STUDY;
D O I
10.1016/0720-048X(94)90100-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this double-blind, parallel-group study was to compare the safety, tolerance, and efficacy of iomeprol-350 (350 mgI/ml), iomeprol-400 (400 mgI/ml) and iopamidol-370 (370 mgI/ml) for use in contrast-enhanced body computed tomography (CT). Following written informed consent, 120 adult inpatients of either sex requiring CT of thoracic or abdominal organs were randomly assigned to receive iomeprol-350, iomeprol-400 or iopamidol-370. Pre- and post-contrast, all patients underwent clinical, instrumental and laboratory investigation to assess the safety of the test agents. Tolerance was assessed in terms of discomfort associated with contrast injection. Two experienced radiologists independently and blindly graded the quality of contrast enhancement obtained with the different contrast solutions by means of a five-point ordinal scale as follows: 1, insufficient; 2, sufficient; 3, good; 4, excellent; or E, excessive. Patients in the iomeprol groups needed fewer injections and a smaller volume of contrast medium to obtain examinations of adequate diagnostic quality. Contrast enhancement was judged as excellent or good in about 90% of the study examinations, without significant differences between the three study groups. During contrast injection, heat and pain sensations were minimal or absent in most cases. No serious adverse events occurred throughout the study. No significant changes in clinical, instrumental or laboratory safety parameters were observed. In conclusion, iomeprol-400 and iomeprol-350 appear to be contrast solutions at least as safe, well tolerated and effective as iopamidol-370 when used as contrast agents for body CT.
引用
收藏
页码:S88 / S92
页数:5
相关论文
共 50 条
  • [21] CONTRAST-ENHANCED COMPUTED-TOMOGRAPHY IN ACUTE-PANCREATITIS - IS IT BENEFICIAL OR HARMFUL
    BALTHAZAR, EJ
    FREENY, PC
    GASTROENTEROLOGY, 1994, 106 (01) : 259 - 262
  • [22] THE USE OF A FLOW-RATE INJECTOR FOR CONTRAST-ENHANCED COMPUTED-TOMOGRAPHY
    MCCARTHY, S
    MOSS, AA
    RADIOLOGY, 1984, 151 (03) : 800 - 800
  • [24] DETAIL VERSUS CONTRAST IN COMPUTED-TOMOGRAPHY
    HUTCHINS, L
    SPELLER, RD
    BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (628): : 379 - 380
  • [25] A RANDOMIZED DOUBLE-BLIND TRIAL OF IOVERSOL AND IOPAMIDOL IN CONTRAST-ENHANCED COMPUTED BODY TOMOGRAPHY
    SAGE, MR
    EVILL, CA
    FON, GT
    INVESTIGATIVE RADIOLOGY, 1989, 24 : S39 - S41
  • [26] FUNCTIONAL IMAGING IN COMPUTED-TOMOGRAPHY - THE USE OF CONTRAST-ENHANCED COMPUTED-TOMOGRAPHY FOR THE STUDY OF RENAL-FUNCTION AND PHYSIOLOGY - DISCUSSION
    DAWSON, P
    PORTER, G
    SIEGLE, R
    GOLDFARB, S
    INVESTIGATIVE RADIOLOGY, 1993, 28 : S85 - S86
  • [27] Abdominal Cocoon: "Cauliflower Sign" on Contrast-Enhanced Computed Tomography Scan
    Ethiraj, Dillibabu
    Indiran, Venkatraman
    GE PORTUGUESE JOURNAL OF GASTROENTEROLOGY, 2020, 28 (01) : 76 - 77
  • [28] CONTRAST-ENHANCED ABDOMINAL COMPUTED-TOMOGRAPHY SCANNING AND PREDICTION OF SEVERITY OF ACUTE-PANCREATITIS - A PROSPECTIVE-STUDY
    LONDON, NJM
    NEOPTOLEMOS, JP
    LAVELLE, J
    BAILEY, I
    JAMES, D
    BRITISH JOURNAL OF SURGERY, 1989, 76 (03) : 268 - 272
  • [29] Dynamic contrast-enhanced computed tomography
    Brix, G.
    Griebel, J.
    Delorme, S.
    RADIOLOGE, 2012, 52 (03): : 277 - 296
  • [30] ASSESSMENT OF SAPHENOUS-VEIN GRAFT PATENCY BY CONTRAST-ENHANCED COMPUTED-TOMOGRAPHY
    ULLYOT, DJ
    TURLEY, K
    MCKAY, CR
    BRUNDAGE, BH
    LIPTON, MJ
    EBERT, PA
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1982, 83 (04): : 512 - 518