LIGHTNING ARRESTERS FOR METAL CLAD SF6 SWITCHGEAR WITH VOLTAGES FROM 72.5 TO 525 KV

被引:0
|
作者
HARTMANN, H
BURGER, U
机构
来源
BROWN BOVERI REVIEW | 1977年 / 64卷 / 11期
关键词
ELECTRIC SWITCHGEAR - Protection;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Depending on the configuration and location within a network of SF//6 switchgear, which is now being installed on an increasing scale, it may be necessary to use SF//6-insulated lightning arresters to protect the main items of equipment, such as the transformers. Based on the familiar technology of the outdoor arrester type HM, the design and mode of operation of the metalclad arrester, and its advantages are described.
引用
收藏
页码:667 / 670
页数:4
相关论文
共 50 条
  • [21] EXTENDED RANGE OF APPLICATION FOR OUTDOOR SF6 CIRCUIT-BREAKERS TYPE ELF FOR 72.5 KV TO 550 KV
    EIDINGER, A
    MENON, KV
    BROWN BOVERI REVIEW, 1981, 68 (3-4): : 120 - 124
  • [22] The Research of Discharge Dispersion of SF6 Breakdown Voltages with the Size of Electrodes Under Lightning Impulse
    You, Haoyang
    Xu, Puming
    Zhang, Qiaogen
    Ma, Jingtan
    Ding, Yuqin
    Zhang, Lingli
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [23] Reliability of SF6 Circuit Breaker Cells and Selection of Switchgear Circuits for 220 kV Substations
    Grinev, N.V.
    Misrikhanov, M. Sh.
    Shuntov, A.V.
    Power Technology and Engineering, 2024, 58 (03) : 507 - 513
  • [24] Application Experience of SF6 -Free 72.5kV Hybrid-Gas-Insulated-Switchgears in China
    Liu, Yitao
    Hong, He
    Lu, Xucheng
    Li, Shuang
    Hou, Yaping
    Zhang, Jun
    Liu, Guangfu
    Zhang, Jiaosuo
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 272 - 274
  • [25] ELF RANGE OF SF6 CIRCUIT-BREAKERS FOR RATED VOLTAGES UP TO 420 KV
    STELZER, R
    GAUPP, O
    BROWN BOVERI REVIEW, 1978, 65 (04): : 262 - 267
  • [26] Breakdown Characteristics of SF6 in Quasi-uniform Field under Oscillating Lightning Impulse Voltages
    Li, Junhao
    Zhang, Liang
    Hu, Degui
    Yao, Xiu
    Xiong, Jun
    Wang, Sisi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) : 915 - 922
  • [27] SF6 Emissions from a National Population of High-Voltage Switchgear
    Runde, Magne
    Istad, Maren
    IEEE ELECTRICAL INSULATION MAGAZINE, 2023, 39 (06) : 16 - 22
  • [28] 550 KV SF6 GAS-INSULATED SWITCHGEAR FOR THE ITAIPU HYDRO-POWER STATION
    SZENTEVARGA, HP
    BROWN BOVERI REVIEW, 1981, 68 (3-4): : 157 - 159
  • [29] Surface Discharge Characteristics of Epoxy Resin in SF6 Gas under Switching and Lightning Impulse Voltages
    Song, Hanlin
    Wu, Yanyu
    Tang, Hao
    Zhou, Xiu
    Chai, Yinghui
    Shan, Bingliang
    Huang, Meng
    Wang, Wei
    2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 147 - 150
  • [30] SF6 CIRCUIT-BREAKERS FOR OUTDOOR AND GIS INSTALLATIONS AT VOLTAGES UP TO 800 KV
    LEUPP, P
    BROWN BOVERI REVIEW, 1983, 70 (1-2): : 53 - 57