THE ELECTRICAL AND ELECTROCHEMICAL PROPERTIES OF GOLD-PLATED INP

被引:18
|
作者
OSKAM, G [1 ]
BART, L [1 ]
VANMAEKELBERGH, D [1 ]
KELLY, JJ [1 ]
机构
[1] UNIV UTRECHT,DEBYE RES INST,POB 80000,3508 TA UTRECHT,NETHERLANDS
关键词
D O I
10.1063/1.354598
中图分类号
O59 [应用物理学];
学科分类号
摘要
The electrical properties of InP/Au dry contacts and the influence of electrodeposited gold on the electrochemical properties of InP electrodes were studied. From current and impedance measurements on InP/Au dry contacts it is concluded that the chemical composition of an interfacial layer strongly influences the electrical characteristics. Furthermore, interface states are shown to play an important role. The interfacial layer and the interface states also determine to a large extent the electrochemical properties of the gold-plated electrodes.
引用
收藏
页码:3238 / 3245
页数:8
相关论文
共 50 条
  • [21] FRETTING CORROSION OF GOLD-PLATED CONNECTOR CONTACTS
    ANTLER, M
    DROZDOWICZ, MH
    WEAR, 1981, 74 (01) : 27 - 50
  • [22] Pressure of light produced gold-plated stars
    Hecht, J
    NEW SCIENTIST, 1996, 152 (2052) : 20 - 20
  • [23] Effects of temperature on fretting corrosion behaviors of gold-plated copper alloy electrical contacts
    Ren, Wanbin
    Wang, Peng
    Fu, Yinghua
    Pan, Cunfa
    Song, Jian
    TRIBOLOGY INTERNATIONAL, 2015, 83 : 1 - 11
  • [24] VOLTAMMETRIC AND POTENTIOMETRIC DETERMINATION OF GOLD IN GOLD-PLATED ELECTROTECHNICAL COMPONENTS
    VYTRAS, K
    SVANCARA, I
    RENGER, F
    SREY, M
    VANKOVA, R
    HVIZDALOVA, M
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1993, 58 (09) : 2039 - 2046
  • [25] THE MEDICAL-LITERATURE SYSTEM - GOLD OR GOLD-PLATED - REPLY
    COOPER, DS
    RIDGEWAY, EC
    ANNALS OF INTERNAL MEDICINE, 1983, 98 (04) : 562 - 562
  • [27] Contact allergy to gold in patients with gold-plated intracoronary stents
    Svedman, C
    Tillman, C
    Gustavsson, CG
    Möller, H
    Frennby, B
    Bruze, M
    CONTACT DERMATITIS, 2006, 54 (01) : 71 - 71
  • [28] Contact allergy to gold in patients with gold-plated intracoronary stents
    Honari, G
    Taylor, JS
    Ellis, S
    CONTACT DERMATITIS, 2005, 53 (06) : 359 - 359
  • [29] Contact allergy to gold in patients with gold-plated intracoronary stents
    Svedman, C
    Tillman, C
    Gustavsson, CG
    Möller, H
    Frennby, B
    Bruze, M
    CONTACT DERMATITIS, 2005, 52 (04) : 192 - 196
  • [30] DEGRADATION MECHANISMS IN TIN-PLATED AND GOLD-PLATED CONNECTOR CONTACTS
    YASUDA, K
    UMEMURA, S
    AOKI, T
    IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1987, 10 (03): : 456 - 462