HIGH-TEMPERATURE CORROSION OF WATER WALL TUBE IN COALFIRED COMBUSTION GASES

被引:13
|
作者
NAKAGAWA, K
KITAGAWA, M
TUMITA, Y
OOKI, S
机构
[1] ISHIKAWAJIMA HARIMA HEAVY IND CO LTD,DEPT BOILER BASIC DESIGN,KOTO KU,TOKYO 13,JAPAN
[2] CHUBU ELECT CO INC,CTR ELECT POWER RES & DEV,MIDORI KU,NAGOYA 459,JAPAN
来源
JOURNAL DE PHYSIQUE IV | 1993年 / 3卷 / C9期
关键词
D O I
10.1051/jp4:1993982
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The effect of stoichiometry ratio and ash deposits on the corrosion of mild steel and 0.5Cr-0.5Mo steel has been investigated at 450-degrees-C in the simulated combustion gases burning three kinds of coals. Under the assumption that the gas reacts with the metal at the same temperature as the surface and gas has not changed in composition, the corrosion behavior could be estimated from the Fe-S-O phase stability diagram at 450-degrees-C and pseudo equilibrium P(s2) and P(O2) based on H2O : H-2 at 1200-degrees-C for simulated combustion gases. Ash deposits accelerated the corrosion rates of steels. It is considered that ash deposits act as catalyst and shift the gas composition to the low temperature equilibrium state.