EVALUATION OF IMMUNOCYTOCHEMICAL STAINING AS A METHOD OF IMPROVING DIAGNOSTIC-ACCURACY IN A ROUTINE CYTOPATHOLOGY LABORATORY

被引:9
|
作者
WAZIR, JF [1 ]
MARTINBATES, E [1 ]
WOODWARD, G [1 ]
COLEMAN, DV [1 ]
机构
[1] ST MARYS HOSP,SCH MED,DEPT CYTOPATHOL,PRAED ST,LONDON W2 1NY,ENGLAND
关键词
IMMUNOCYTOCHEMICAL STAINS; EFFUSIONS; FNA;
D O I
10.1111/j.1365-2303.1991.tb00390.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Immunocytochemical stains in a routine cytopathology laboratory can be used to distinguish between benign and malignant cells, and to identify tumour type. In our laboratory 30 problematic cases were selected for immunocytochemical stains and the results analysed in this paper. The following markers were used: cytokeratin (CAM5.2), carcinoembryonic antigen (CEA), kappa and lambda light chains, leucocytic common antigen (LCA), chorionic gonadotrophin (hCG), prostate specific antigen (PSA), L26, UCHL1, S100-protein and vimentin. Twelve FNA (four lymph nodes, one parotid swelling, two from lungs, two from pleura and chest wall, one from lumbar region, two from soft tissue masses), and 18 effusions (12 pleural effusions, five ascitic fluids, one pericardial effusion) were investigated. We found immunocytochemical stains of value in formulating the cytological diagnosis in 11/12 of FNA and 15/18 of effusions.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 50 条
  • [41] IMPROVED LABORATORY EFFICIENCY AND DIAGNOSTIC-ACCURACY WITH NEW DOUBLE-LUMEN-PROTECTED SWAB FOR ENDOMETRIAL SPECIMENS
    PEZZLO, MT
    HESSER, JW
    MORGAN, T
    VALTER, PJ
    THRUPP, LD
    JOURNAL OF CLINICAL MICROBIOLOGY, 1979, 9 (01) : 56 - 59
  • [42] IMPROVING DIAGNOSTIC-ACCURACY OF CERVICAL METASTASES WITH COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING - REPLY
    HILLSAMER, PJ
    SCHULLER, DE
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1991, 117 (08) : 933 - 933
  • [43] DIAGNOSTIC ACCURACY OF IRRIGATION SMEAR METHOD IN GENERAL LABORATORY
    CHRISTOF.P
    ACTA PATHOLOGICA ET MICROBIOLOGICA SCANDINAVICA SECTION A-PATHOLOGY, 1970, : 25 - &
  • [44] An iron-hematoxylin-anilin-blue staining method for routine laboratory use
    Koneff, AA
    ANATOMICAL RECORD, 1936, 66 (02): : 173 - 179
  • [45] DIAGNOSTIC-TESTS FOR PNEUMONIA IN VENTILATED PATIENTS - PROSPECTIVE EVALUATION OF DIAGNOSTIC-ACCURACY USING HISTOLOGY AS A DIAGNOSTIC GOLD-STANDARD
    MARQUETTE, CH
    COPIN, MC
    WALLET, F
    NEVIERE, R
    SAULNIER, F
    MATHIEU, D
    DUROCHER, A
    RAMON, P
    TONNEL, AB
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (06) : 1878 - 1888
  • [46] IMP3 immunocytochemical staining increases sensitivity in the routine cytologic evaluation of biliary brush specimens
    Hart, Jesse
    Parab, Meena
    Mandich, Daniza
    Cartun, Richard W.
    Ligato, Saverio
    DIAGNOSTIC CYTOPATHOLOGY, 2012, 40 (04) : 321 - 326
  • [47] DIAGNOSTIC-ACCURACY OF INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY (IVDSA) IN THE EVALUATION OF PATENCY OF AC-BYPASS
    TAKAMIYA, M
    NISHIMURA, G
    NAITO, H
    KOZUKA, T
    KIMURA, K
    OHTA, M
    KIMURA, M
    IDE, K
    YAMADA, T
    KURISU, Y
    KITO, Y
    OHARA, K
    FUJITA, T
    HAZE, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1983, 47 (08): : 883 - 884
  • [48] IMPROVED DIAGNOSTIC-ACCURACY WITH THE EVALUATION OF ECG-CHANGES IN EXERCISE-INDUCED SUPRAVENTRICULAR EXTRASYSTOLES
    MICHAELIDES, AP
    VYSSOULIS, GP
    PSOMADAKI, ZD
    KYRIAKIDIS, MK
    TOUTOUZAS, PK
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1994, 8 (01): : 20 - 27
  • [49] ESTIMATING DIAGNOSTIC-ACCURACY FROM MULTIPLE CONFLICTING REPORTS - A NEW META-ANALYTIC METHOD
    LITTENBERG, B
    MOSES, LE
    RABINOWITZ, D
    CLINICAL RESEARCH, 1990, 38 (02): : A415 - A415
  • [50] A METHOD TO STUDY THE EFFECT OF CONTROLLED CHANGES OF BREAST IMAGE TOTAL SYSTEM MTFS ON DIAGNOSTIC-ACCURACY
    BENCOMO, JA
    HAUS, AG
    PAULUS, DD
    HILL, CE
    LOGAN, WW
    JOHNSTON, DA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (02) : 426 - 426