Effect of Intraocular Pressure and Anisotropy on the Optical Properties of the Cornea: A Study Using Polarization Sensitive Optical Coherence Tomography

被引:4
|
作者
Richhariya, Ashutosh [1 ]
Verma, Yogesh [2 ]
Rao, Divakar K. [2 ]
Roberts, Cynthia J. [3 ]
Mahmoud, Ashraf M. [3 ]
Sangwan, Virender S. [1 ]
Punjabi, Sunil [4 ]
Gupta, Pradeep K. [2 ]
机构
[1] LV Prasad Eye Inst, Cornea & Anterior Segment Serv, Hyderabad, Andhra Pradesh, India
[2] Raja Ramanna Ctr Adv Technol, Laser Biomed Applicat Instrumentat Div, Indore, Madhya Pradesh, India
[3] Ohio State Univ, Biomed Engn & Ophthalmol, Columbus, OH 43210 USA
[4] Ujjain Engn Coll, Mech Engn, Ujjain, Madhya Pradesh, India
来源
ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY | 2014年 / 3卷 / 06期
关键词
cornea; intraocular pressure; polarization sensitive optical coherence tomography; birefringence; corneal imaging;
D O I
10.1097/APO.0000000000000015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We hypothesize that because of the anisotropic properties of the cornea, there should be a nonuniform change in birefringence with an increase in intraocular pressure (IOP). In this in vitro study, anisotropic properties, stress distribution within the cornea, and the effect of IOP on changes in stress level were investigated. Design: Button inflation tests for deformation with polarization sensitive optical coherence tomography were used to demonstrate optical and material anisotropy on ex vivo human corneas. Methods: Inflation tests were performed on human donor corneoscleral rims. Using a turntable and hydrostatic column, each corneoscleral rim was subjected to a hydrostatic pressure of 0, 10, 15, and 20 mm Hg. At each pressure step, 4 scans at 0, 45, 90, and 135 degrees were taken by a polarization sensitive optical coherence tomography system, and the birefringence images and normal intensity-based images were recorded; images were later compiled for analysis. Results: The retardation changed with the axis of orientation (P [T <= t] 1-tailed = 0.025) and IOP (P [T <= t] 1-tailed = 0.019). Optical thickness of the cornea decreased with increasing IOP. Conclusions: The optical properties of the cornea are modified with change in IOP. This is not uniform because of distinct anisotropic properties. Anisotropic properties may unpredictably affect the optical quality of cornea during or after the surgeries. Changes in corneal birefringence can be also used as a tool for measuring the IOP of the eye.
引用
收藏
页码:348 / 353
页数:6
相关论文
共 50 条
  • [41] Polarization-sensitive interleaved optical coherence tomography
    Duan, Lian
    Marvdashti, Tahereh
    Ellerbee, Audrey K.
    OPTICS EXPRESS, 2015, 23 (10): : 13693 - 13703
  • [42] Regional polarization sensitivity of articular cartilage by using polarization sensitive optical coherence tomography
    Xie, Tuqiang
    Guo, Shuguang
    Chen, Zhongping
    Peavy, George M.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [43] Complex polarization ratio to determine polarization properties of anisotropic tissue using polarization-sensitive optical coherence tomography
    Park, Jesung
    Kemp, Nate J.
    Rylander, H. Grady, III
    Milner, Thomas E.
    OPTICS EXPRESS, 2009, 17 (16): : 13402 - 13417
  • [44] Study of optical properties and proteoglycan content of tendons by polarization sensitive optical coherence tomography (vol 17, 081417, 2012)
    Yang, Ying
    Rupani, Asha
    Bagnaninchi, Pierre
    Wimpenny, Ian
    Weightman, Alan
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)
  • [45] Revealing anisotropic properties of cornea at different intraocular pressures using optical coherence elastography
    Li, Jiasong
    Singh, Manmohan
    Han, Zhaolong
    Wu, Chen
    Nair, Achuth
    Aglyamov, Salavat R.
    Twa, Michael D.
    Larin, Kirill V.
    OPTICAL ELASTOGRAPHY AND TISSUE BIOMECHANICS III, 2016, 9710
  • [46] Polarization properties of ocular tissue imaged with polarization sensitive spectral domain optical coherence tomography
    Goetzinger, Erich
    Pircher, Michael
    Hitzenberger, Christoph K.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [47] Polarization properties of retinal blood vessel walls measured with polarization sensitive optical coherence tomography
    Afsharan, Hadi
    Hackmann, Michael J.
    Wang, Qiang
    Navaeipour, Farzaneh
    Jayasree, Stephy Vijaya Kumar
    Zawadzki, Robert J.
    Silva, Dilusha
    Joo, Chulmin
    Cense, Barry
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (07): : 4340 - 4362
  • [48] Passive optical module for polarization-sensitive optical coherence tomography systems
    Rivet, Sylvain
    Marques, Manuel J.
    Bradu, Adrian
    Podoleanu, Adrian
    OPTICS EXPRESS, 2017, 25 (13): : 14533 - 14544
  • [49] Measurements of scattering changes using polarization-sensitive optical coherence tomography
    Lee, Sang-Won
    Kang, Jin-Ho
    Yoo, Ji-Yeong
    Kim, Beop-Min
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3350 - 3352
  • [50] Identification and Characterization of Pseudodrusen using Polarization-Sensitive Optical Coherence Tomography
    Baratsits, Magdalena
    Schlanitz, Ferdinand Georg
    Roberts, Philipp Ken
    Zotter, Stefan
    Baumann, Bernhard
    Pircher, Michael
    Hitzenberger, Christoph K.
    Schmidt-Erfurth, Ursula
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)