Implant Overdenture Using Konus Telescope on One-piece Implant: A Case Report

被引:2
|
作者
Ohkubo, Chikahiro [1 ]
Kobayashi, Mariko [1 ]
Okamoto, Naoko [1 ]
Hosoi, Toshio [1 ]
Kurtz, Kenneth S. [1 ]
Murata, Toshiyuki [1 ]
机构
[1] Tsurumi Univ, Sch Dent Med, Dept Removable Prosthodont, Tsurumi Ku, 2-1-3 Tsurumi, Yokohama, Kanagawa 2308501, Japan
关键词
one-piece implant; telescopic denture; retention; stability; laser welding;
D O I
10.1922/EJPRD_804Ohkubo04
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
An implant-retained Konus (tapered double crown) telescopic complete overdenture was fabricated for a mandibular edentulous patient. The Konus telescopic overdenture coping crowns and framework assembly were cast with commercially pure (CP) titanium, joined using laser welding and placed on four one-piece implants. Sufficient retention and stability were obtained using this method.
引用
下载
收藏
页码:188 / 191
页数:4
相关论文
共 50 条
  • [1] Simplifying the implant treatment for an unrestorable premolar with a one-piece implant: A clinical report
    Swart, Louwrens C.
    van Niekerk, Dirk J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (02): : 81 - 85
  • [2] Reliability of One-Piece Ceramic Implant
    Silva, Nelson R. F. A.
    Coelho, Paulo G.
    Fernandes, Carlos A. O.
    Navarro, Jose M.
    Dias, Renata Alves
    Thompson, Van P.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (02) : 419 - 426
  • [3] A 1-year clinical report of a one-piece implant abutment
    Carlson, B
    Jönsson, G
    Sandahl, L
    Nordin, T
    Hising, P
    Nelvig, P
    Branting, C
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2001, 14 (02) : 159 - 163
  • [4] One-piece Implant Placement as an Alternative and Acceptable Treatment for Missing Tooth Rehabilitation: A Case Report
    Teguh, Paulus Budi
    Nanik, Chaterina Diyah
    ARCHIVES OF OROFACIAL SCIENCE, 2021, 16 : 67 - 72
  • [5] EFFECT OF ONE-PIECE IMPLANT DIAMETER ON CLINICAL OUTCOME
    Fanali, S.
    Carinci, F.
    Zollino, I.
    Brunelli, G.
    Monguzzi, R.
    EUROPEAN JOURNAL OF INFLAMMATION, 2011, 9 (03) : 7 - 12
  • [6] Stress distribution in a zirconia one-piece dental implant
    Correia, A.
    Reis Campos, J. C.
    Couto Viana, P.
    Kovacs, Z.
    Ramos, N. V.
    Vaz, M.
    BIODENTAL ENGINEERING II, 2014, : 173 - 175
  • [7] IMPACT OF ONE-PIECE IMPLANT LENGTH ON CLINICAL OUTCOME
    Fanali, S.
    Carinci, F.
    Zollino, I.
    Brunelli, G.
    Monguzzi, R.
    EUROPEAN JOURNAL OF INFLAMMATION, 2011, 9 (03) : 13 - 18
  • [8] A ONE-PIECE OCULAR DRAINAGE IMPLANT FOR GLAUCOMA SURGERY - A PRELIMINARY-REPORT
    KIVALO, M
    RAITTA, C
    MONONEN, T
    ACTA VETERINARIA SCANDINAVICA, 1992, 33 (04) : 317 - 324
  • [9] One-piece implant in reduced edentulous space closure: A report of two cases
    Christopher, Sunil Dutt
    Savitha, A. N.
    CONTEMPORARY CLINICAL DENTISTRY, 2013, 4 (04) : 563 - 565
  • [10] Fractographic analyses of failed one-piece zirconia implant restorations
    Oilo, Marit