A 1-year clinical report of a one-piece implant abutment

被引:0
|
作者
Carlson, B
Jönsson, G
Sandahl, L
Nordin, T
Hising, P
Nelvig, P
Branting, C
机构
[1] Gavle Dent Implant Ctr, SE-80250 Gavle, Sweden
[2] Sundsvall Cty Clin, Dept Prosthodont, Sundsvall, Sweden
[3] Sundsvall Cty Hosp, Dept Oral & Maxillofacial Surg, Sundsvall, Sweden
[4] Sophiahemmet, Dept Oral & Maxillofacial Surg, Stockholm, Sweden
[5] Sterngold ImplaMed, Ingaro, Sweden
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Solid one-piece standard and conical abutments, which do not involve the external implant hex when seated, have been designed. The present clinical study represents a 1-year follow-up of the use of these abutments for anchorage of implant-supported fixed prostheses for oral rehabilitation of 36 completely and eight partially edentulous patients. Materials and Methods: After 1 year of loading, the implant-supported dentures were removed, and the seating of the 214 one-piece abutments was inspected clinically and radiographically. Results: After 1 year of loading, no loose abutments were observed. One complication was reported; it involved fracture of two abutment screws within the same fixed denture. Prosthesis mobility and gold screw loosening accompanied this complication. Ninety-one percent of the patients exhibited healthy gingiva, and 9% showed erythema/edema. No periimplantitis was identified. Conclusion: The results of this study-healthy marginal tissue, a mean bone loss of 0.3 +/- 0.6 mm, and no abutment retightening 1 year after loading-support the use of the one-piece abutment design in implant-supported screw-retained restorations.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [1] Simplifying the implant treatment for an unrestorable premolar with a one-piece implant: A clinical report
    Swart, Louwrens C.
    van Niekerk, Dirk J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (02): : 81 - 85
  • [2] EFFECT OF ONE-PIECE IMPLANT DIAMETER ON CLINICAL OUTCOME
    Fanali, S.
    Carinci, F.
    Zollino, I.
    Brunelli, G.
    Monguzzi, R.
    EUROPEAN JOURNAL OF INFLAMMATION, 2011, 9 (03) : 7 - 12
  • [3] IMPACT OF ONE-PIECE IMPLANT LENGTH ON CLINICAL OUTCOME
    Fanali, S.
    Carinci, F.
    Zollino, I.
    Brunelli, G.
    Monguzzi, R.
    EUROPEAN JOURNAL OF INFLAMMATION, 2011, 9 (03) : 13 - 18
  • [4] Managing a fractured one-piece zirconia abutment with a modified plastic periodontal probe: A clinical, report
    Saponaro, Paola C.
    Lee, Damian J.
    McGlumphy, Edwin A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (05): : 587 - 591
  • [5] Reliability of One-Piece Ceramic Implant
    Silva, Nelson R. F. A.
    Coelho, Paulo G.
    Fernandes, Carlos A. O.
    Navarro, Jose M.
    Dias, Renata Alves
    Thompson, Van P.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (02) : 419 - 426
  • [6] Implant Overdenture Using Konus Telescope on One-piece Implant: A Case Report
    Ohkubo, Chikahiro
    Kobayashi, Mariko
    Okamoto, Naoko
    Hosoi, Toshio
    Kurtz, Kenneth S.
    Murata, Toshiyuki
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2009, 17 (04): : 188 - 191
  • [7] Direct loading of Nobel Direct® and Nobel Perfect® one-piece implants:: a 1-year prospective clinical and radiographic study
    Ostman, Per-Olov
    Hellman, Mats
    Albrektsson, Tomas
    Sennerby, Lars
    CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (04) : 409 - 418
  • [8] Bone Response From a Dynamic Stimulus on a One-Piece and Multi-Piece Implant Abutment and Crown by Finite Element Analysis
    Hajimiragha, Habib
    Abolbashari, Mohammadreza
    Nokar, Saeed
    Abolbashari, AmirHossein
    Abolbashari, Mehrdad
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (05) : 525 - 532
  • [9] A ONE-PIECE OCULAR DRAINAGE IMPLANT FOR GLAUCOMA SURGERY - A PRELIMINARY-REPORT
    KIVALO, M
    RAITTA, C
    MONONEN, T
    ACTA VETERINARIA SCANDINAVICA, 1992, 33 (04) : 317 - 324
  • [10] One-piece implant in reduced edentulous space closure: A report of two cases
    Christopher, Sunil Dutt