HIGH-PRECISION AND SPATIAL-RESOLUTION SULFUR ISOTOPE ANALYSIS USING MILES LASER MICROPROBE

被引:0
|
作者
BEAUDOIN, G [1 ]
TAYLOR, BE [1 ]
机构
[1] GEOL SURVEY CANADA,OTTAWA,ON K1A 0E8,CANADA
关键词
D O I
10.1016/0016-7037(94)90231-3
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The MILES (Micro In situ Laser Extraction System) laser microprobe permits high spatial resolution (< 10(-3) mm3, or <0.2 mumol S) in situ sampling of geological material for sulfur isotope analysis. Sulfides are combusted in F2 by absorption of CO2 laser radiation and converted to sulfur hexafluoride (SF6). The product SF6 is purified by cryogenic distillation. In combination with a high-sensitivity dual-inlet isotope ratio mass spectrometer, sulfur isotope analyses of powders of pyrite, galena, and sphalerite yield delta34S(CDT) values with a high precision, ranging from 0.03 to 0.09 parts per thousand. The sulfur isotope ratios measured are accurate and exhibit no matrix-dependent sulfur isotope effects over the range of 62 parts per thousand. A minimum F2 pressure of 20 kPa (for MILES) is required to mediate against small isotopic fractionations between multiple sulfur species apparently caused by laser isotope separation and/or reaction with oxygen during analysis. The precision and accuracy of delta34S(CDT) values from in situ analyses are good (less-than-or-equal-to 0.2 parts per thousand), but isotopically homogeneous working standards or intercomparison materials are not available thus far. Sulfur isotope ratios derived by conventional-SO2 and laser-SF6 are well correlated (r2 = 0.99999), but a slope different from unity (m = 1.035) arises, probably due to inadequate corrections to SO2 data for oxygen isobaric interferences. Sulfur isotope isopleths in a large, cubic metamorphic pyrite porphyroblast, determined from 79 in situ analyses, are discordant to crystallographic zonation. Concordance between crystallographic and isotopic zonation needs be tested using high precision and spatial resolution analyses such as those described here. Sampling crystallographic zones in minerals can result in erroneous conclusions if isotopic and crystallographic zoning are not coincident.
引用
收藏
页码:5055 / 5063
页数:9
相关论文
共 50 条
  • [31] High-precision laser beam shaping using a binary-amplitude spatial light modulator
    Liang, Jinyang
    Kohn, Rudolph N., Jr.
    Becker, Michael F.
    Heinzen, Daniel J.
    APPLIED OPTICS, 2010, 49 (08) : 1323 - 1330
  • [32] High-precision isotopic analysis: Lessons from 'clumped isotope' geochemistry
    Eiler, John M.
    Guo, Weifu
    Huntington, Katharine
    Passey, Benjamin
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A240 - A240
  • [33] An efficient method for high-precision potassium isotope analysis in carbonate materials
    Wang, Xi-Kai
    Liu, Xiao-Ming
    Chen, Heng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2410 - 2419
  • [34] An efficient method for high-precision potassium isotope analysis in carbonate materials
    Wang, Xi-Kai
    Liu, Xiao-Ming
    Chen, Heng
    Journal of Analytical Atomic Spectrometry, 2022,
  • [35] Constructing High-Precision and Spatial Resolution Precipitable Water Vapor Product Using Multiple Fusion Models
    Zhou, Yi
    Wang, Xinzhi
    Zhang, Jianhang
    Xu, Chang
    Cui, Xiwang
    Chen, Fayuan
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2024, 17 : 17998 - 18011
  • [36] High-precision sulfur isotope composition of enstatite meteorites and implications of the formation and evolution of their parent bodies
    Defouilloy, C.
    Cartigny, P.
    Assayag, N.
    Moynier, F.
    Barrat, J. -A.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2016, 172 : 393 - 409
  • [37] HIGH SPATIAL-RESOLUTION LASER RAMAN-SCATTERING DIAGNOSTICS IN FLAMES WITH HYDROCARBON FUELS
    KASAL, P
    ALGERMISSEN, J
    FORSCHUNG IM INGENIEURWESEN-ENGINEERING RESEARCH, 1990, 56 (05): : 150 - 158
  • [38] Development of high-precision rotary encoder using semiconductor laser
    Li, ZG
    Che, YMAH
    SEMICONDUCTOR LASERS III, 1998, 3547 : 285 - 290
  • [39] Development of High-precision Rotary Encoder Using Semiconductor Laser
    MA Hong
    CHE Ying
    LI Zhaohui(Changchun Institute of Optics and Fine Mechanics
    Semiconductor Photonics and Technology, 1996, (03) : 204 - 209
  • [40] High-precision ranging using a chaotic laser pulse train
    Myneni, K
    Barr, TA
    Reed, BR
    Pethel, SD
    Corron, NJ
    APPLIED PHYSICS LETTERS, 2001, 78 (11) : 1496 - 1498