Bradbury-Nielsen gate electrode potential switching modes optimizing the ion packet time width in an ion mobility spectrometer

被引:4
|
作者
Kurnin, Igor V. [1 ]
Krasnov, Nikolai V. [1 ]
Semenov, Sergey Y. [2 ]
Smirnov, Valentin N. [2 ]
机构
[1] Russian Acad Sci, Inst Analyt Instrumentat, Rizhsky Prosp 26, St Petersburg 190103, Russia
[2] Fed State Unitary Enterprise Res & Tech Ctr Radia, Moscow 123182, Russia
关键词
Ionmobility spectrometry; Bradbury-Nielsen gate; Resolving power;
D O I
10.1007/s12127-014-0152-x
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The methods minimizing duration of the output pulse of the ion mobility spectrometer at its maximum intensity were proposed in order to increase the instrument resolution. The optimal duration of the enabling pulse matched with the gate characteristics and ensuring the minimum time width of output ion packet withmaximum intensity was chosen. The following operation modes of the Bradbury-Nielsen gate were considered: 1) time compression of the transmitted ion packet by pulsed increase of the potentials at the some set of wires; 2) instantaneous switching the potentials at the adjacent wires and 3) combination of the instantaneous switching of the potentials on the adjacent wires followed by the time compression of a transmitted ion packet. It was shown that the proposed gate modes ensure minimization of the output ion packet duration and increasing of the ion mobility spectrometer resolution. The estimated resolution of the ion peaks doubles and may reach 200 under considered conditions, space charge not taken into account.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 13 条
  • [1] Study of ion transmission for a linear mode Bradbury-Nielsen gate in ion mobility spectrometer
    Ni, Kai
    Guo, Jingran
    Ou, Guangli
    Zhang, Xiaoguo
    Yu, Quan
    Qian, Xiang
    Wang, Xiaohao
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 379 : 75 - 79
  • [2] Field Switching Combined with Bradbury-Nielsen Gate for Ion Mobility Spectrometry
    Chen, Chuang
    Tabrizchi, Mahmoud
    Wang, Weiguo
    Li, Haiyang
    ANALYTICAL CHEMISTRY, 2015, 87 (15) : 7925 - 7930
  • [3] Modeling the modulation characteristics of the Bradbury-Nielsen gate in ion mobility spectrometers
    Guo, Kaitai
    Zhang, Chong
    Ni, Kai
    Wang, Xiaohao
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (08):
  • [4] Improving Performance of Ion Mobility Spectrometry Using Bradbury-Nielsen Ion Gate Pulse Waveform Modulation
    Cang Huai-Wen
    Li Hang
    Huang Wei
    Zhang Yuan-Zhi
    Li Jing-Hua
    Wang Wei-Guo
    Li Hai-Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (12) : 2067 - 2074
  • [5] Resolution Enhancement of Ion Mobility Spectrometry by Improving the Three-Zone Properties of the Bradbury-Nielsen Gate
    Du, Yongzhai
    Wang, Weiguo
    Li, Haiyang
    ANALYTICAL CHEMISTRY, 2012, 84 (03) : 1725 - 1731
  • [6] Bradbury-Nielsen vs. Field switching shutters for high resolution drift tube ion mobility spectrometers
    Kirk, Ansgar T.
    Zimmermann, Stefan
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2014, 17 (3-4) : 131 - 137
  • [7] Note: Design and construction of a simple and reliable printed circuit board-substrate Bradbury-Nielsen gate for ion mobility spectrometry
    Du, Yongzhai
    Cang, Huaiwen
    Wang, Weiguo
    Han, Fenglei
    Chen, Chuang
    Li, Lin
    Hou, Keyong
    Li, Haiyang
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (08):
  • [8] Enhancing ion mobility spectrometry performance through a programmable ion swarm shaping method based on Bradbury-Nielsen gates
    Wang, Jiyao
    Chen, Hai
    Ling, Yiyuan
    Zhang, Chong
    Zhou, Haobo
    Wang, Xiaohao
    Ni, Kai
    TALANTA, 2024, 269
  • [9] A simple template-based transfer method to fabricate Bradbury-Nielsen gates with uniform tension for ion mobility spectrometry
    Ni Kai
    Guo Jingran
    Ou Guangli
    Lei Yu
    Yu Quan
    Qian Xiang
    Wang Xiaohao
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (08):
  • [10] Bradbury-Nielsen-Gate-Grid Structure for Further Enhancing the Resolution of Ion Mobility Spectrometry
    Du, Yongzhai
    Wang, Weiguo
    Li, Haiyang
    ANALYTICAL CHEMISTRY, 2012, 84 (13) : 5700 - 5707