PULSE OXIMETRY VERSUS MEASURED ARTERIAL OXYGEN-SATURATION - A COMPARISON OF THE NELLCOR N100 AND THE BIOX-III

被引:16
|
作者
LEBECQUE, P
SHANGO, P
STIJNS, M
VLIERS, A
COATES, AL
机构
[1] CATHOLIC UNIV LOUVAIN, CLIN ST LUC, B-1200 BRUSSELS, BELGIUM
[2] MCGILL UNIV, MONTREAL CHILDRENS HOSP, INST RES, MONTREAL H3H 1P3, QUEBEC, CANADA
关键词
CONGENITAL HEART DISEASE; SAO2 STANDARD BY IL-282 COOXIMETER; BIAS AND PRECISION; EFFECTS OF BLOOD PIGMENT; CARDIAC INDEX AGE;
D O I
10.1002/ppul.1950100216
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Pulse oximetry is noninvasive, fast, and simple, making it a very popular way of assessing oxygenation in pediatric patients. However, there are few studies that establish the accuracy of this technology over a wide range of oxygen saturations in children. This study, done in 47 children aged from 1 day to 16 years with congenital heart disease and undergoing cardiac catheterization, compared the direct measurement of arterial oxygen saturation to values from pulse oximetry. Oxygen satuation was measured by an IL-282 Co-oximeter, which also measured carboxyhemoglobin and methemoglobin, and was compared to values obtained from both a Biox III and Nellcor N100. Both pulse oximeters gave values that closely correlated with the actual saturation (r = 0.91 and 0.93, respectively) with standard errors of the estimate of 4.1 and 3.2%, respectively. For both devices, the error increased with decreasing saturations, being progressively larger below a saturation of 80%. The difference between the actual saturation and that measured by pulse oximetry bore no relationship to the presence of carboxyhemoglobin, methemoglobin, fetal hemoglobin, bilirubin, cardiac index, or age of the patient. In conclusion, pulse oximetry, while a very useful technology in pediatrics, must be interpreted with some caution in children with severe cyanosis.
引用
收藏
页码:132 / 135
页数:4
相关论文
共 29 条
  • [21] Reflectance pulse oximetry from core body in neonates and infants: Comparison to arterial blood oxygen saturation and to transmission pulse oximetry
    Kugelman A.
    Wasserman Y.
    Mor F.
    Goldinov L.
    Geller Y.
    Bader D.
    Journal of Perinatology, 2004, 24 (6) : 366 - 371
  • [22] Accuracy of a third (Dolphin Voyager) versus first generation pulse oximeter (Nellcor N-180) in predicting arterial oxygen saturation and pulse rate in the anesthetized dog
    Burns, Patrick M.
    Driessen, Bernd
    Boston, Ray
    Gunther, Robert A.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2006, 33 (05) : 281 - 295
  • [23] EFFECTS OF MULTIPLE-SCATTERING AND PERIPHERAL-CIRCULATION ON ARTERIAL OXYGEN-SATURATION MEASURED WITH A PULSE-TYPE OXIMETER
    SHIMADA, Y
    YOSHIYA, I
    OKA, N
    HAMAGURI, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (05) : 475 - 478
  • [24] Fetal arterial oxygen saturation trends measured by continuous pulse oximetry during labor in subjects with normal delivery outcomes
    De Morais, EN
    Spara, P
    Gressler, JT
    4TH WORLD CONGRESS OF PERINATAL MEDICINE, 1999, : 139 - 142
  • [25] A Comparison of Oxygen Saturation in White-tailed Deer Estimated by Pulse Oximetry and from Arterial Blood Gases
    Muller, Lisa I.
    Osborn, David A.
    Doherty, Tom
    Keel, M. Kevin
    Miller, Brad F.
    Warren, Robert J.
    Miller, Karl V.
    JOURNAL OF WILDLIFE DISEASES, 2012, 48 (02) : 458 - 461
  • [26] ARTERIAL OXYGEN-SATURATION DURING ND-YAG LASER PHOTORESECTION OF ENDOBRONCHIAL TUMORS UNDER LOCAL-ANESTHESIA - USE OF INTERMITTENT SUPPLEMENTAL OXYGEN WITH PULSE OXIMETRY GUIDANCE
    SCHIFFMAN, PL
    WILHELM, J
    PARISI, RA
    CHEST, 1988, 94 (06) : 1300 - 1301
  • [28] Masimo Signal Extraction Technology Pulse Oximetry Concerning the Article by RJ Rosychuk et al.: Discrepancies between Arterial Oxygen Saturation and Functional Oxygen Saturation Measured with Pulse Oximetry in Very Preterm Infants [Neonatology 2012;101:14-19] Reply
    Rosychuk, Rhonda J.
    Hudson-Mason, Ann
    Lacaze-Masmonteil, Thierry
    NEONATOLOGY, 2012, 101 (04) : 240 - 240
  • [29] Type III home sleep testing versus pulse oximetry: is the respiratory disturbance index better than the oxygen desaturation index to predict the apnoea-hypopnoea index measured during laboratory polysomnography?
    Dawson, Arthur
    Loving, Richard T.
    Gordon, Robert M.
    Abel, Susan L.
    Loewy, Derek
    Kripke, Daniel F.
    Kline, Lawrence E.
    BMJ OPEN, 2015, 5 (06):