EFFECTS OF SUBANESTHETIC CONCENTRATIONS OF NITROUS-OXIDE ON COLD-PRESSOR PAIN IN HUMANS

被引:13
|
作者
PIREC, V
PATTERSON, TH
THAPAR, P
APFELBAUM, JL
ZACNY, JP
机构
[1] UNIV CHICAGO,DEPT ANESTHESIA & CRIT CARE,CHICAGO,IL 60637
[2] UNIV CHICAGO,PRITZKER SCH MED,DEPT PSYCHIAT,CHICAGO,IL 60637
关键词
NITROUS OXIDE; ANALGESIA; PAIN; SUBJECTIVE; HUMAN; VOLUNTEER;
D O I
10.1016/0091-3057(94)00388-Y
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
Nitrous oxide (N2O) has analgesic properties as determined in both animal and human research. In the present study, we sought to determine whether N2O given in subanesthetic concentrations would reduce cold presser (CP)-induced pain. A crossover, double-blind study was conducted in 10 healthy volunteers. Each subject participated in four separate sessions, and in each session the effects of one of four concentrations of N2O in oxygen (0, 20, 30, and 40%) were assessed. The duration of inhalation was 40 min, and within each session, subjects immersed their nondominant arm in water (2-3 degrees C) twice for 3 min (at 10 and 30 min intrainhalation). Pain intensity, the degree to which the pain was bothersome (measured on a verbal scale of 0-10, 0 = ''not at all'' and 10 = ''extremely'' painful/bothersome), and pain quality [measured by the short-form McGill Pain Questionnaire (SF-MPQ)] were assessed during the forearm immersion. Mood effects were measured with the use of visual analogue scales (VAS) in the presence and absence of pain. Self-reported pain intensity and bothersomeness, SF-MPQ ratings of ''sharp pain'' and ''throbbing pain,'' and VAS rating of ''unpleasant bodily sensations'' were significantly reduced by N2O (p < 0.05) in a concentration-dependent manner. Nitrous oxide had a number of effects on mood (e.g., increased VAS ratings of ''stimulated,'' ''high,'' ''coasting,'' ''carefree,'' and ''having pleasant bodily sensations''). The cold-water immersion also influenced mood, but had little impact on modulating N2O effects. Results from our study indicate that the CP test is a sensitive assay to measure the analgesic properties of subanesthetic concentrations of N2O in humans.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 50 条
  • [21] EFFECTS OF LOW CONCENTRATIONS OF NITROUS-OXIDE ON RAT PREGNANCY
    CORBETT, TH
    CORNELL, RG
    ENDRES, JL
    MILLARD, RI
    ANESTHESIOLOGY, 1973, 39 (03) : 299 - 301
  • [22] EFFECTS OF A SUBANESTHETIC CONCENTRATION OF NITROUS-OXIDE ON OVERT AND COVERT ASSESSMENTS OF MEMORY AND ASSOCIATIVE PROCESSES
    BLOCK, RI
    GHONEIM, MM
    PATHAK, D
    KUMAR, V
    HINRICHS, JV
    PSYCHOPHARMACOLOGY, 1988, 96 (03) : 324 - 331
  • [23] UPTAKE AND EXCRETION OF SUBANESTHETIC CONCENTRATIONS OF NITROUS OXIDE IN MAN
    SALANITRE, E
    EPSTEIN, RM
    KLONYMUS, D
    RACKOW, H
    GREENE, LT
    ANESTHESIOLOGY, 1962, 23 (06) : 814 - &
  • [24] ACUTE TOLERANCE TO NITROUS-OXIDE IN HUMANS
    RAMSAY, DS
    BROWN, AC
    WOODS, SC
    PAIN, 1992, 51 (03) : 367 - 373
  • [25] EFFECTS OF NITROUS-OXIDE
    BOYUM, R
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1981, 103 (01): : 10 - &
  • [26] Subjective, psychomotor, cognitive, and analgesic effects of subanesthetic concentrations of sevoflurane and nitrous oxide
    Galinkin, JL
    Janiszewski, D
    Young, CJ
    Klafta, JM
    Klock, PA
    Coalson, DW
    Apfelbaum, JL
    Zacny, JP
    ANESTHESIOLOGY, 1997, 87 (05) : 1082 - 1088
  • [27] SUBJECTIVE AND PSYCHOMOTOR EFFECTS OF BOLUS DOSES OF NITROUS-OXIDE IN HUMANS
    DOHRN, CS
    LICHTOR, JL
    COALSON, DW
    FLEMMING, D
    ZACNY, JP
    HUMAN PSYCHOPHARMACOLOGY-CLINICAL AND EXPERIMENTAL, 1993, 8 (02) : 97 - 106
  • [28] RESPIRATORY EFFECTS OF NITROUS-OXIDE DURING ENFLURANE ANESTHESIA IN HUMANS
    LAM, AM
    CLEMENT, JL
    CHUNG, DC
    KNILL, RL
    ANESTHESIOLOGY, 1982, 56 (04) : 298 - 303
  • [29] SUBANESTHETIC DOSES OF KETAMINE, DIAZEPAM, AND NITROUS-OXIDE FOR ADULT OUTPATIENT SEDATION
    TUCKER, MR
    HANN, JR
    PHILLIPS, CL
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1984, 42 (10) : 668 - 672
  • [30] NITROUS-OXIDE CONCENTRATIONS IN DENTAL OPERATORY
    MILLARD, RI
    CORBETT, TH
    JOURNAL OF ORAL SURGERY, 1974, 32 (08): : 593 - 594