AMPEROMETRIC ASSAY OF GLUCOSE AND URIC-ACID BY A FLOW-INJECTION SYSTEM USING A PEROXIDASE ADSORBED CARBON ELECTRODE AS AN ELECTROCHEMICAL DETECTOR

被引:0
|
作者
IWAI, H [1 ]
AKIHAMA, S [1 ]
机构
[1] MEIJI COLL PHARM,SETAGAYA KU,TOKYO 154,JAPAN
关键词
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
引用
收藏
页码:S22 / S22
页数:1
相关论文
共 50 条
  • [41] Flow injection amperometric sensing of uric acid and ascorbic acid using the self-assembly of heterocyclic thiol on Au electrode
    Dey, Ramendra Sundar
    Gupta, Susmita
    Paira, Rupankar
    Chen, Shen-Ming
    Raj, C. Retna
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (01) : 173 - 178
  • [42] Flow injection amperometric sensing of uric acid and ascorbic acid using the self-assembly of heterocyclic thiol on Au electrode
    Ramendra Sundar Dey
    Susmita Gupta
    Rupankar Paira
    Shen-Ming Chen
    C. Retna Raj
    [J]. Journal of Solid State Electrochemistry, 2012, 16 : 173 - 178
  • [43] THEORY AND APPLICATION OF DIFFUSION-LIMITED AMPEROMETRIC ENZYME ELECTRODE DETECTION IN FLOW-INJECTION ANALYSIS OF GLUCOSE
    OLSSON, B
    LUNDBACK, H
    JOHANSSON, G
    SCHELLER, F
    NENTWIG, J
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (06) : 1046 - 1052
  • [44] EVALUATION OF DISPERSION IN A FLOW-INJECTION SYSTEM BY ELECTROCHEMICAL DETECTOR AND PERSONAL-COMPUTER
    KAKIZAKI, T
    HASEBE, K
    YOSHIDA, H
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 326 (03): : 214 - 217
  • [46] A Prussian blue-carbon paste electrode for selective cathodic amperometric determination of nitrite using a flow-injection analysis system with carrier recycling
    Pradela-Filho, Lauro A.
    Oliveira, Brandon C.
    Takeuchi, Regina M.
    Santos, Andre L.
    [J]. ELECTROCHIMICA ACTA, 2015, 180 : 939 - 946
  • [47] Flow-injection amperometric determination of ascorbic acid using a graphite-epoxy composite electrode modified with cobalt phthalocyanine
    Khorasani, JH
    Amini, MK
    Ghanei, H
    Tangestaninejad, S
    [J]. IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2001, 20 (02): : 66 - 74
  • [48] AMPEROMETRIC DETERMINATION OF METAL-IONS IN A FLOW-INJECTION SYSTEM WITH A COPPER-AMALGAM ELECTRODE
    ALEXANDER, PW
    AKAPONGKUL, U
    [J]. ANALYTICA CHIMICA ACTA, 1983, 148 (APR) : 103 - 109
  • [49] FACTORS CONCERNING THE DESIGN AND CALIBRATION OF AN AMPEROMETRIC ENZYME ELECTRODE SYSTEM FOR THE FLOW-INJECTION ANALYSIS OF CHOLESTEROL
    MOODY, GJ
    SANGHERA, GS
    THOMAS, JDR
    [J]. ANALYST, 1988, 113 (09) : 1419 - 1422
  • [50] FLOW-INJECTION ANALYSIS OF HYDROGEN-PEROXIDE USING A HORSERADISH PEROXIDASE-MODIFIED ELECTRODE DETECTION SYSTEM
    SANCHEZ, PD
    BLANCO, PT
    ALVAREZ, JMF
    SMYTH, MR
    OKENNEDY, R
    [J]. ELECTROANALYSIS, 1990, 2 (04) : 303 - 308