Treatment of idiopathic macular hole with silicone oil tamponade

被引:5
|
作者
Ivanovska-Adjievska, Biljana [1 ]
Boskurt, Salih [1 ]
Semiz, Faruk [1 ]
Yuzer, Hakan [1 ]
Dimovska-Jordanova, Vesna [2 ]
机构
[1] European Eye Hosp, Ul Sremski Front br 1, Skopje 1000, Macedonia
[2] Univ St Cyril & Methodius, Clin Eye Dis, Skopje, Macedonia
来源
CLINICAL OPHTHALMOLOGY | 2012年 / 6卷
关键词
macular hole; silicone oil; ILM peeling; pars plana vitrectomy;
D O I
10.2147/OPTH.S33902
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We analyzed the anatomical and visual outcomes after surgical treatment of idiopathic macular holes with pars plana vitrectomy, internal limiting membrane (ILM) peeling using Brilliant Blue dye, and silicone oil tamponade without postoperative posturing. Methods: This was a retrospective interventional study of 10 eyes in eight patients who underwent surgical treatment of idiopathic macular holes using pars plana vitrectomy, ILM peeling using Brilliant Blue dye, and silicone oil tamponade without postoperative posturing. The preoperative staging of macular holes and postoperative anatomic outcomes were assessed using spectral-domain optical coherence tomography. Results: All patients were women with a mean age of 66.86 +/- 4.8 years. In two patients, bilateral macular holes were present and both eyes were operated on. Stage 2 macular hole was diagnosed in three eyes, three eyes had stage 3, and four eyes had stage 4 macular holes. Anatomical success and closure of the macular hole was achieved in nine eyes (90%) after one operation. In one eye, the macular hole was closed after reoperation. The preoperative mean best-corrected visual acuity (BCVA) was 0.15 decimal units (0.8 logMAR units). Until the end of the follow-up period, BCVA was 0.25 decimal units (0.6 logMAR units). Visual acuity was improved in seven patients (70%). In two patients (20%), visual acuity remained at the same level, and in one eye (10%), visual acuity decreased. Postoperatively, all patients reported a significant reduction of metamorphopsia. Conclusion: Initial results after 20G pars plana vitrectomy with peeling of the ILM, use of dye (Brilliant Blue), and tamponade with silicone oil without postoperative posturing gave good anatomical and functional outcome in terms of visual acuity and reduction of metamorphopsia. Taking into account the age of the patients, this method, which does not require prolonged postoperative face-down posturing, was well tolerated by the patients. Because the anatomical and visual outcome as well as the rate of postoperative complications are comparable to those when gas is used as a tamponading agent, silicone oil tamponade can also be safely used as a first option in surgery of macular holes. However, a longer period of follow-up of the operated eyes, as well as a larger group of operated eyes, will be required to identify long-term outcomes of this surgical treatment.
引用
收藏
页码:1449 / 1454
页数:6
相关论文
共 50 条
  • [41] TREATMENT OF RETINAL DETACHMENT SECONDARY TO MACULAR HOLE IN HIGHLY MYOPIC EYES Pars Plana Vitrectomy with Internal Limiting Membrane Peel and Silicone Oil Tamponade
    Meng, Li
    Wei, Wenbin
    Li, Yanlong
    Han, Xiaodong
    Shi, Xiaobo
    Yang, Min
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (03): : 470 - 476
  • [42] Retinal Hemorrhages After Silicon Oil Tamponade in Macular Hole Surgery
    Cappello, E.
    Tollot, L.
    Zemella, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [43] Silicone oil tamponade to seal macular holes without position restrictions - Discussion
    Tornambe, PE
    OPHTHALMOLOGY, 1998, 105 (11) : 2147 - 2148
  • [44] Macular Edema Following Silicone Oil Tamponade for Retinal Detachment: A Literature Review
    Kontou, Evgenia P.
    Karakosta, Christina
    Kounas, Konstantinos
    Iatropoulos, Ioannis
    Tsinopoulos, Ioannis
    Kozobolis, Vassilios
    Stavrakas, Panagiotis
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (12)
  • [45] Short-Acting Gas Tamponade with Strict Face-Down Posturing for the Treatment of Idiopathic Macular Hole
    Gotzaridis, Stratos
    Liazos, Efstathios
    Petrou, Petros
    Georgalas, Ilias
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (05) : 597 - 601
  • [46] Complications of silicone oil tamponade
    Baillif, S.
    Gastaud, P.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2014, 37 (03): : 259 - 265
  • [47] INTERNAL TAMPONADE BY SILICONE OIL IN RETINAL-DETACHMENT TREATMENT
    CHAUVAUD, D
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1986, 9 (03): : 251 - 260
  • [48] Vitrectomy with sulfur hexafluoride versus air tamponade for idiopathic macular hole: a retrospective study
    Yuou Yao
    Huichao Yan
    Jinfeng Qu
    Chongya Dong
    Jianhong Liang
    Hong Yin
    Chi Ren
    Enzhong Jin
    Mingwei Zhao
    BMC Ophthalmology, 23
  • [49] DYNAMICS OF THE MACULAR HOLE-SILICONE OIL TAMPONADE INTERFACE WITH PATIENT POSITIONING AS IMAGED BY SPECTRAL DOMAIN-OPTICAL COHERENCE TOMOGRAPHY
    Oster, Stephen F.
    Mojana, Francesca
    Bartsch, Dirk-Uwe G.
    Goldbaum, Michael
    Freeman, William R.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (06): : 924 - 929
  • [50] Macular hole surgery with air tamponade
    Gesser, C.
    Eckert, T.
    Eckardt, U.
    Porkert, U.
    Eckardt, C.
    OPHTHALMOLOGE, 2010, 107 (11): : 1043 - +