ERRORS IN TRACHEAL PRESSURE RECORDING IN PATIENTS WITH A TRACHEOSTOMY TUBE - A MODEL STUDY

被引:13
|
作者
HOLST, M
STRIEM, J
HEDENSTIERNA, G
机构
[1] HUDDINGE UNIV HOSP,DEPT ANAESTHESIOL,S-14186 HUDDINGE,SWEDEN
[2] HUDDINGE UNIV HOSP,DEPT INTENS CARE,S-14186 HUDDINGE,SWEDEN
[3] UNIV HOSP UPPSALA,UPPSALA,SWEDEN
关键词
Airway pressure; Resistance; Trachea; Tracheotomy;
D O I
10.1007/BF01735176
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The recording of intratracheal pressure in patients breathing through a tracheostomy tube is marred by methodological problems. In model experiments it has been shown that the introduction of a recording catheter into the tracheostomy tube alters the recorded pressure by as much as 20-40%. To avoid such inaccuracy, a specially designed tracheostomy tube is proposed with an externally placed channel for introduction of the recording catheter. In in vivo measurements, recordings can be made at a distance of up to about 20 mm below the end of tube. Pressure recordings from this part of a model trachea are compared with results obtained from a reference pressure port 100 mm below the tube ending. The results show that it is possible to record expiratory pressure with good accuracy but that inspiratory pressure is still overestimated by 9-16%. © 1990 Springer-Verlag.
引用
收藏
页码:384 / 389
页数:6
相关论文
共 50 条
  • [41] PRESSURE CHANGES IN TRACHEAL TUBE CUFFS
    CHANDLER, M
    ANAESTHESIA, 1986, 41 (03) : 287 - 293
  • [42] A PRESSURE REGULATOR FOR THE CUFF OF A TRACHEAL TUBE
    MILLER, DM
    ANAESTHESIA, 1992, 47 (07) : 594 - 596
  • [43] TRACHEAL TUBE CUFF PRESSURE - REPLY
    LATTO, IP
    WILLIS, BA
    ANAESTHESIA, 1989, 44 (12) : 1002 - 1002
  • [44] Adjusting tracheal tube cuff pressure
    Kunstyr, Jan
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (04) : 280 - 280
  • [45] Do Not Burn Your Airway Bridge: A Technique to Safely Exchange a Tracheostomy Tube for a Tracheal Tube
    Alejandro Patino, Miguel
    Dam-Thuy Truong
    Truong, Angela
    Cata, Juan Pablo
    A & A CASE REPORTS, 2016, 7 (07) : 155 - 157
  • [46] ACCURATE TRACHEAL TUBE CITE PRESSURE MEASUREMENT IN INTENSIVE CARE PATIENTS
    Taylor, J.
    Bloomfield, R.
    INTENSIVE CARE MEDICINE, 2011, 37 : S108 - S108
  • [47] Tracheostomy tube changes in patients with tracheostomy: A quality improvement project
    Liu, Yu
    Zhou, Chunlan
    Wu, Yanni
    Deng, Shuijuan
    Chen, Ying
    Zhou, Jungui
    NURSING IN CRITICAL CARE, 2024, 29 (06) : 1470 - 1478
  • [48] TRACHEOSTOMY TUBE CONNECTIONS FOR INFANT PATIENTS
    INKSTER, JS
    BRAY, RJ
    MAYBEE, L
    ANAESTHESIA, 1980, 35 (06) : 595 - 598
  • [49] Cuff pressure control of the tracheal tube: a prospective study in a general ICU
    GS Cardoso
    HP Guimarães
    RD Lopes
    PHR Leal
    AP Resque
    CJ Guedes
    FRP Souza
    FR Machado
    JLG Amaral
    Critical Care, 9 (Suppl 2):
  • [50] Dilation of tracheal stenosis below tracheostomy tube with Dolphin percutaneous tracheostomy kitTracheal stenosis treated with Dolphin PDT
    Alfonso Fiorelli
    Mary Bove
    Antonio Noro
    Angela Iuorio
    Mario Santini
    Fausto Ferraro
    General Thoracic and Cardiovascular Surgery, 2020, 68 : 655 - 658