EFFECTIVENESS OF RADIOFREQUENCY CATHETER ABLATION FOR TREATMENT OF ATRIAL TACHYCARDIA

被引:50
|
作者
GOLDBERGER, J
KALL, J
EHLERT, F
DEAL, B
OLSHANSKY, B
BENSON, DW
BAERMAN, J
KOPP, D
KADISH, A
WILBER, D
机构
[1] NORTHWESTERN UNIV,SCH MED,DEPT MED,DIV CARDIOL,CHICAGO,IL 60611
[2] NORTHWESTERN UNIV,SCH MED,DEPT PEDIAT,CHICAGO,IL 60611
[3] LOYOLA UNIV,DEPT MED,DIV CARDIOL,MAYWOOD,IL 60153
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1993年 / 72卷 / 11期
关键词
D O I
10.1016/0002-9149(93)91063-N
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Catheter ablation has been used to treat atrioventricular node reentrant and atrioventricular reentrant tachycardias with extremely high success rates. The suitability of catheter ablation for treatment of atrial tachycardia, a much less common type of supraventricular tachycardia, has not been well addressed. Fifteen patients (8 females) ranging from 10 to 83 years (mean 38 +/- 22) were referred for catheter ablation of supraventricular tachycardia. The diagnosis of atrial tachycardia was established by standard electrophysiologic techniques. A combination of activation and pace mapping was used to identify a suitable site for radiofrequency current catheter ablation. Medical therapy was unsuccessful in all but 1 patient. Two patients had surgically corrected congenital heart disease, 2 had coronary artery disease and 1 had dilated cardiomyopathy. Seven patients had depressed left ventricular function. Six patients had incessant tachycardias. Presumed tachycardia mechanism was automatic in 11 patients and reentrant in 4. Mean tachycardia cycle length was 372 +/- 74 ms. Catheter ablation was acutely successful in 12 patients (80%) with application of 11.1 +/- 6.6 lesions at a mean voltage of 60 +/- 9 V. In the other 3 patients, 16 to 38 lesions were applied. At a mean follow-up of 18.5 +/- 6.5 months, 2 patients have had recurrences with different P-wave morphologies and underwent a second successful catheter ablation procedure. An additional 2 patients had recurrences with the same P-wave morphology and 1 underwent a second successful catheter ablation procedure. Thus, radiofrequency ablation can be used in a diverse population of patients with atrial tachycardia with an acute success rate of 80% and a long-term success rate of 73%.
引用
收藏
页码:787 / 793
页数:7
相关论文
共 50 条
  • [32] Radiofrequency catheter ablation for treatment of paroxysmal supraventricular tachycardia in children
    Ding, YS
    Li, XM
    Ren, ZW
    Chen, J
    Wu, L
    VI ASIAN-PACIFIC SYMPOSIUM ON CARDIAC PACING AND ELECTROPHYSIOLOGY, 1997, : 313 - 317
  • [33] Radiofrequency catheter ablation in young patients with permanent junctional reciprocating tachycardia and atrial ectopic tachycardia
    Bokenkamp, R
    Bertram, H
    Trappe, HJ
    Luhmer, I
    Paul, T
    ZEITSCHRIFT FUR KARDIOLOGIE, 1998, 87 (05): : 364 - 371
  • [34] Radiofrequency Ablation for Atrial Tachycardia and Atrial Flutter
    Walters, Tomos E.
    Kistler, Peter M.
    Kalman, Jonathan M.
    HEART LUNG AND CIRCULATION, 2012, 21 (6-7): : 386 - 394
  • [35] Radiofrequency ablation of atrial tachycardia and atrial flutter
    López Gil M.
    Arribas F.
    Cosío F.G.
    Zeitschrift für Kardiologie, 2000, 89 (Suppl 3): : III144 - III152
  • [36] Radiofrequency ablation of atrial tachycardia and atrial flutter
    Gil, ML
    Arribas, F
    Cosío, FG
    ZEITSCHRIFT FUR KARDIOLOGIE, 2000, 89 : 144 - 152
  • [37] Permanent left atrial tachycardia: Radiofrequency catheter ablation through the coronary sinus
    Pavin, D
    Boulmier, D
    Daubert, JC
    Mabo, P
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (04) : 395 - 398
  • [38] ADENOSINE VERAPAMIL SENSITIVE ATRIAL TACHYCARDIA - ENDOCARDIAL MAPPING AND RADIOFREQUENCY CATHETER ABLATION
    MUNSIF, AN
    LIEM, LB
    YOUNG, C
    LAUER, MR
    YU, JCL
    SUNG, RJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A155 - A155
  • [39] Successful radiofrequency catheter ablation of automatic atrial tachycardia with regression of the cardiomyopathy picture
    Chiladakis, JA
    Vassilikos, VP
    Maounis, TN
    Cokkinos, DV
    Manolis, AS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (04): : 953 - 959
  • [40] Radiofrequency catheter ablation of atrial tachycardia using noncontact computerized mapping system
    Bhatia, A
    Sra, J
    Dhala, A
    Blanck, Z
    Deshpande, S
    Baig, S
    Cooley, R
    Berger, M
    Akhtar, M
    CIRCULATION, 2000, 102 (18) : 527 - 527