Luminol-K3Fe(CN)(6) chemiluminescence system for the determination of glipizide

被引:6
|
作者
Chen, Xin [1 ]
Xing, Li-Li [2 ]
Tang, Yu-Hai [2 ]
Zhang, Guang-Bin [2 ]
机构
[1] 405 Hosp Hanzhong City, Hanzhong 723312, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Inst Analyt Sci, Xian 710061, Shaanxi, Peoples R China
关键词
Luminol-K3Fe(CN)(6); Glipizide; Flow injection; Chemiluminescence;
D O I
10.1016/j.jpha.2012.07.002
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A rapid and sensitive flow-injection chemiluminescence (CL) method for the determination of glipizide was developed on the basis of finding that glipizide can enhance the CL intensity of the luminol-K3Fe(CN)(6) system. In optimum condition, the increased CL intensity was directly proportional to the concentration of glipizide in the range from 4.0 x 10 (8) g/mL to 1.0 x 10 (6) g/ mL and the detection limit was 1.0 x 10 (-8) g/mL glipizide. The relative standard deviation (RSD) of the developed method was 2.1% with 11 repeated measurements of 1.0 x 10(-7) g/mL glipizide. The developed method has been successfully applied to the analysis of glipizide in its pharmaceutical preparations. (C) 2013 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 50 条
  • [1] Luminol-K3Fe(CN)6 chemiluminescence system for the determination of glipizide
    Xin Chen
    Li-Li Xing
    Yu-Hai Tang
    Guang-Bin Zhang
    [J]. Journal of Pharmaceutical Analysis, 2013, 3 (02) : 127 - 131
  • [2] Chemiluminescence determination of melamine with Luminol-K3Fe(CN)6 system
    Xiao-Shuang Tang1
    2 Institute of Analytical Sciences
    [J]. Journal of Pharmaceutical Analysis, 2011, 1 (02) : 104 - 107
  • [3] Chemiluminescence determination of melamine with Luminol-K3Fe(CN)(6) system
    Tang, Xiao-Shuang
    Shi, Xi-Yan
    Tang, Yu-Hai
    Yue, Zhong-Jin
    He, Qi-Qi
    [J]. JOURNAL OF PHARMACEUTICAL ANALYSIS, 2011, 1 (02) : 104 - 107
  • [4] FLOW INJECTION CHEMILUMINESCENCE DETERMINATION OF THIAMINE BY THE ENHANCEMENT OF LUMINOL-K3Fe(CN)6 SYSTEM
    Li, Y. H.
    Yang, Y.
    Lu, J. R.
    [J]. BIOLUMINESCENCE AND CHEMILUMINESCENCE: LIGHT EMISSION: BIOLOGY AND SCIENTIFIC APPLICATIONS, 2009, : 221 - 224
  • [5] Determination of doxorubicin in pharmaceutical preparation and rat plasma with luminol-K3Fe(CN)6 chemiluminescence system
    Yao, Han-Chun
    Xu, Er-Jun
    Zeng, Wen-Yuan
    Zeng, Xiao-Ying
    Zhang, Min
    Chen, Juan
    [J]. JOURNAL OF FOOD AND DRUG ANALYSIS, 2013, 21 (03) : 279 - 285
  • [6] Enhanced chemiluminescence of the luminol-K3Fe(CN)6 system by ZnSe quantum dots and its application
    Guo, Cheng
    Zeng, Huajin
    Ding, Xiaojie
    He, Dou
    Li, Jianjun
    Yang, Ran
    Qu, Lingbo
    [J]. JOURNAL OF LUMINESCENCE, 2013, 134 : 888 - 892
  • [7] Ultrasensitive assay of rhein in medicine based on its enhanced luminol-K3Fe(CN)6 chemiluminescence reaction using the flow injection technique
    Liu, EB
    Xue, BC
    [J]. MICROCHIMICA ACTA, 2006, 153 (1-2) : 51 - 56
  • [8] Ultrasensitive Assay of Rhein in Medicine Based on its Enhanced Luminol-K3Fe(CN)6 Chemiluminescence Reaction Using the Flow Injection Technique
    Erbao Liu
    Bingchun Xue
    [J]. Microchimica Acta, 2006, 153 : 51 - 56
  • [9] Black Phosphorus Quantum Dots with Exposed (113) Planes on Chemiluminescent Luminol-K3Fe(CN)6 for Detection of Dopamine
    Zhao, Yijing
    Yang, Chen
    Yang, Yuqing
    Sun, Yan
    Wang, Qing
    Zhang, Meiqi
    Wang, Didi
    Liu, Pengchao
    Dong, Yongping
    Li, Chunsheng
    Dai, Guoliang
    Guo, Wen
    Ye, Mingfu
    Zhao, Yuzhen
    Dou, Yuhai
    Li, Guangjun
    [J]. ACS APPLIED NANO MATERIALS, 2024, 7 (11) : 12993 - 13003
  • [10] Indirect chemiluminescence detection for capillary zone electrophoresis of monoamines and catechol using luminol-K3[Fe(CN)6] system
    Hu, YG
    Li, XX
    Pang, ZT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1091 (1-2) : 194 - 198