DETERMINATION OF GLUCOSE IN FERMENTATION PROCESSES BY MEANS OF AN ONLINE COUPLED FLOW-INJECTION SYSTEM USING ENZYME SENSORS BASED ON CHEMICALLY MODIFIED ELECTRODES

被引:23
|
作者
APPELQVIST, R [1 ]
HANSEN, EH [1 ]
机构
[1] TECH UNIV DENMARK,DEPT CHEM A,BLDG 207,DK-2800 LYNGBY,DENMARK
关键词
Biosensors; Enzyme electrode; Fermentation;
D O I
10.1016/S0003-2670(00)82083-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of an inexpensive, easy-to-make and disposable biosensor, based on a chemically modified graphite electrode with an adsorbed and cross-linked layer of glucose dehydrogenase, as a detector in a flow-injection system for on-line monitoring of glucose in fermenters is described. The performance of the sensor as a function of time is investigated, and used for assaying glucose in a wine fermentation process. It is concluded that the sensor operates satisfactorily during at least 3 days of continuous use. No interference from ethanol is encountered. With regard to practical applications, special emphasis is placed on the interfacing of the fermenter and the analytical system. © 1990.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 50 条
  • [1] FLOW-INJECTION ANALYSIS FOR GLUCOSE WITH CHEMICALLY MODIFIED ENZYME MEMBRANE-ELECTRODE
    YAO, T
    NAKANISHI, K
    WASA, T
    BUNSEKI KAGAKU, 1984, 33 (04) : 213 - 217
  • [2] CHEMICALLY MODIFIED RETICULATED VITREOUS CARBON ELECTRODE WITH IMMOBILIZED ENZYME AS A DETECTOR IN FLOW-INJECTION DETERMINATION OF GLUCOSE
    WIECK, HJ
    HEIDER, GH
    YACYNYCH, AM
    ANALYTICA CHIMICA ACTA, 1984, 158 (01) : 137 - 141
  • [3] ENZYME ENTRAPPED POLYPYRROLE MODIFIED ELECTRODE FOR FLOW-INJECTION DETERMINATION OF GLUCOSE
    TROJANOWICZ, M
    MATUSZEWSKI, W
    PODSIADLA, M
    BIOSENSORS & BIOELECTRONICS, 1990, 5 (02): : 149 - 156
  • [5] DETERMINATION OF GLUCOSE USING FLOW-INJECTION WITH A CARBON-FIBER BASED ENZYME REACTOR
    ANG, KP
    GUNASINGHAM, H
    TAY, BT
    HERATH, VS
    TEO, PYT
    THIAK, PC
    KUAH, B
    TAN, KL
    ANALYST, 1987, 112 (10) : 1433 - 1435
  • [6] A FLOW-INJECTION SYSTEM FOR ASSAY OF THE ACTIVITY OF AN IMMOBILIZED ENZYME CHEMICALLY-MODIFIED ELECTRODE
    OSBORN, JA
    YACYNYCH, AM
    ROBERTS, DC
    ANALYTICA CHIMICA ACTA, 1986, 183 : 287 - 292
  • [7] DETERMINATION OF GLUCOSE IN ALCOHOLIC BEVERAGES BY FLOW-INJECTION WITH 2 INTERNALLY COUPLED INJECTION VALVES AND AN ENZYME REACTOR
    RUZ, J
    RIOS, A
    DECASTRO, MDL
    VALCARCEL, M
    ANALYTICA CHIMICA ACTA, 1988, 211 (1-2) : 281 - 285
  • [8] DETERMINATION OF PHOSPHATIDYLCHOLINE IN A FLOW-INJECTION SYSTEM USING IMMOBILIZED ENZYME REACTORS
    MASOOM, M
    ROBERTI, R
    BINAGLIA, L
    ANALYTICAL BIOCHEMISTRY, 1990, 187 (02) : 240 - 245
  • [9] SPECTROPHOTOMETRIC DETERMINATION OF ETHANOL IN BLOOD USING A FLOW-INJECTION SYSTEM WITH AN IMMOBILIZED ENZYME (ALCOHOL-DEHYDROGENASE) REACTOR COUPLED TO AN ONLINE DIALYZER
    MAEDER, G
    VEUTHEY, JL
    PELLETIER, M
    HAERDI, W
    ANALYTICA CHIMICA ACTA, 1990, 231 (01) : 115 - 119
  • [10] DETERMINATION OF CREATINE-KINASE ACTIVITY USING A CO-IMMOBILIZED AUXILIARY ENZYME REACTOR COUPLED ONLINE WITH A FLOW-INJECTION SYSTEM
    FERNANDEZROMERO, JM
    DECASTRO, MDL
    ANALYST, 1991, 116 (02) : 167 - 169