SIMULTANEOUS TRANSMISSION-EMISSION TL-201 CARDIAC SPECT - EFFECT OF ATTENUATION CORRECTION ON MYOCARDIAL TRACER DISTRIBUTION

被引:0
|
作者
FICARO, EP [1 ]
FESSLER, JA [1 ]
ACKERMANN, RJ [1 ]
ROGERS, WL [1 ]
CORBETT, JR [1 ]
SCHWAIGER, M [1 ]
机构
[1] UNIV MICHIGAN,MED CTR,DEPT INTERNAL MED,DIV NUCL MED,ANN ARBOR,MI 48109
关键词
TRANSMISSION TOMOGRAPHY; SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY; CORONARY ARTERY DISEASE; ATTENUATION CORRECTION; CARDIAC IMAGING;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study evaluates the effect of attenuation correction on regional myocardial tracer distributions defined by Tl-201 cardiac perfusion SPECT images obtained from healthy volunteers and patients with coronary heart disease. Methods: A three-detector SPECT system equipped with an Am-241 line source and a fanbeam collimator was used for simultaneous transmission/emission (Tl-201) tomography on 40 patients and 10 normal volunteers. Uncorrected emission images were reconstructed using filtered backprojection (FBP), whereas the attenuation corrected images were iteratively reconstructed with a regularized, least-squares algorithm utilizing the attenuation map computed from the transmission data. Both sets of images were reoriented into short-axis and vertical long-axis slices. Circumferential profile analysis was applied to both datasets of short-axis slices. Results: The normal volunteers demonstrated improved homogeneity in tracer distribution. For a basal short-axis slice, the lateral-to-posterior activity ratio improved from 1.17 +/- 0.12 for FBP to 1.01 +/- 0.07. Basal attenuation appeared properly compensated as the peak basal-to-apical slice activity gradient along the posterior-inferior wall changed from 1.15 +/- 0.12 for FBP to 1.01 +/- 0.09. The apex of the attenuation corrected images showed a significant decrease in activity relative to the base which appeared consistent with anatomic wall thinning. For the inferior and basal septal regions, the defect severity was slightly less in the attenuation corrected images, but the defects were more sharply defined compared to the FBP image defects. Conclusion: These results indicate that attenuation correction is clinically feasible and accurately corrects for photon attenuation. Clinical validation, however, is necessary to define the diagnostic benefits.
引用
收藏
页码:921 / 931
页数:11
相关论文
共 50 条
  • [31] Extracardiac activity complicates quantitative cardiac SPECT imaging using a simultaneous transmission-emission approach
    Heller, EN
    DeMan, P
    Liu, YH
    Dione, DP
    Zubal, IG
    Wackers, FJT
    Sinusas, AJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (12) : 1882 - 1890
  • [32] Transmission-emission attenuation correction of myocardial SPECT. Impact on false positive rate in a population at low-risk of CAD.
    Fanti, S
    Dondi, M
    Guidalotti, PL
    Fagioli, G
    Corbelli, C
    Monetti, N
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 308 - 308
  • [33] SPILL CORRECTION TECHNIQUE FOR SIMULTANEOUS REST TL-201 STRESS TC-99M MYOCARDIAL PERFUSION SPECT - A PHANTOM STUDY
    KNESAUREK, K
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P189 - P189
  • [34] EVALUATION OF TL-201 MYOCARDIAL EMISSION COMPUTED-TOMOGRAPHY (SPECT) BASED ON A COMPARISON WITH POSTMORTEM FINDINGS
    NAGASHIMA, J
    NISHINO, H
    YAMAGATA, A
    TANNO, M
    CHIBA, K
    YAMADA, H
    OHKAWA, S
    SUGIURA, M
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1986, 50 (08): : 776 - 776
  • [35] DOBUTAMINE ECHOCARDIOGRAPHY, TL-201 SPECT AND POSITRON EMISSION TOMOGRAPHY, WHICH TEST FOR THE PREDICTION OF MYOCARDIAL VIABILITY
    GERBER, B
    VANOVERSCHELDE, JL
    ROBERT, A
    DHONDT, AM
    KOCK, MD
    BOL, A
    MELIN, JA
    CIRCULATION, 1994, 90 (04) : 314 - 314
  • [36] FALSE-POSITIVE PERFUSION DEFECTS AND IMAGE DISTORTION OF 180 DEGREE ACQUIRED TL-201 MYOCARDIAL SPECT IMAGES WITH AND WITHOUT ATTENUATION CORRECTION
    MACINTYRE, WJ
    GO, RT
    HOUSER, T
    PIEZ, C
    ODONNELL, JK
    FEIGLIN, DH
    NAPOLI, C
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1984, 9 (07): : A17 - A17
  • [37] FALSE-POSITIVE PERFUSION DEFECTS AND IMAGE DISTORTIONS OF 180 DEGREE ACQUIRED TL-201 MYOCARDIAL SPECT IMAGES WITH AND WITHOUT ATTENUATION CORRECTION
    GO, RT
    MACINTYRE, WJ
    HOUSER, TS
    PIEZ, C
    ODONNELL, JK
    FEIGLIN, D
    NAPOLI, C
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P61 - P61
  • [38] Diagnosis of coronary artery disease by tl-201 myocardial perfusion spect imaging in patients with cardiac arrhythmias
    Uslu, H.
    Hacimahmutoglu, S.
    Birsel, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S233 - S233
  • [39] POLAR PRESENTATION OF CORONARY ANGIOGRAPHY AND TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY - A METHOD FOR COMPARING ANATOMIC AND PATHOLOGICAL FINDINGS IN CORONARY ANGIOGRAPHY WITH ISOTOPE DISTRIBUTION IN TL-201 MYOCARDIAL SPECT
    SVANE, B
    BONE, D
    HOLMGREN, A
    LANDOU, C
    ACTA RADIOLOGICA, 1989, 30 (06) : 561 - 574
  • [40] A COMPARISON OF GD-153 AND CO-57 AS TRANSMISSION SOURCES FOR SIMULTANEOUS TCT AND TL-201 SPECT
    FREY, EC
    TSUI, BMW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1201 - 1206