PREPARATION OF A DOUBLE-MEMBRANE NITRATE-SELECTIVE ELECTRODE - ESTIMATION OF ITS ESSENTIAL ANALYTICAL CHARACTERISTICS

被引:0
|
作者
ARA, RCD
机构
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A double -membrane nitrate- selective electrode was prepared with an internal conductor membrane made of tetrabutylammonium bromide (BrTBA) and nitrobenzene (PHINO2) in naphtalene as an inert matrix, and an external active membrane (Aliquat - NO3- in paraffin), on a Pt electrode. The electrode exhibits Nernstian response over the range 1 - 10(-3.5) M of nitrate, with a slope of 56.60 +/- 0.3 mV decade-1 at 25.0 +/- 0.2-degrees-C. The detection limit was 10(-3.5) M of nitrate. The reproducibility (coefficient of variation) was 0.11% (n - 10 determinations, for [NO3-] - 10(-3) M). The stability of its potential is 0.5 mV/12 h. The effects of the active membrane composition, the thickness of the membranes and the pH of solution on the electrode response were also investigated.
引用
收藏
页码:329 / 332
页数:4
相关论文
共 40 条
  • [21] Preparation of Nitrate Bilayer Membrane Ion-Selective Electrode Modified by Pericarpium Granati-Derived Biochar and Its Application in Practical Samples
    Guangyao Fozia
    Yanhong Zhao
    Jianrong Nie
    Qian Jiang
    Chaogang Chen
    Xu Wang
    Ming Xu
    Zhangli Ying
    Hong Hu
    Electrocatalysis, 2023, 14 : 534 - 545
  • [22] Construction of a triphenyltetrazolium liquid membrane ion selective electrode and its analytical application to the assay of vitamin C
    Veltsistas, PG
    Sikalos, TI
    Prodromidis, MI
    Papadimitriou, CD
    Karayannis, MI
    MIKROCHIMICA ACTA, 2000, 135 (1-2) : 113 - 117
  • [23] Construction of a Triphenyltetrazolium Liquid Membrane Ion Selective Electrode and its Analytical Application to the Assay of Vitamin C
    Panayotis G. Veltsistas
    Theodosios I. Sikalos
    Mamas I. Prodromidis
    Christos D. Papadimitriou
    Miltiades I. Karayannis
    Microchimica Acta, 2000, 135 : 113 - 117
  • [24] A Simple Heterogenous Precipitate Based Sodium ion Selective Electrode- Its Preparation and Analytical Application
    Selvi, J. Thamarai
    ORIENTAL JOURNAL OF CHEMISTRY, 2011, 27 (03) : 1269 - 1272
  • [25] Preparation, characterization of polyacrylonitrile-aluminum hydroxide composite anion exchanger and its analytical application as AsO4-3 selective membrane electrode
    Khan, Asif Ali
    Shaheen, Shakeeba
    COMPOSITES PART B-ENGINEERING, 2014, 58 : 312 - 317
  • [26] STUDY OF THE INFLUENCE OF SEVERAL INERT MATRICES AND ACTIVE SUBSTANCES IN THE PREPARATION OF A DOUBLE MEMBRANE SELECTIVE ELECTRODE FROM EPHEDRINE
    PASCUAL, PC
    ARA, RCD
    AFINIDAD, 1992, 49 (441) : 316 - 318
  • [27] Construction of a polymeric liquid-membrane ion-selective electrode (ISE)and its application for determination of nitrate in tomatoes
    Pérez, MDA
    Nodarse, IC
    Yazdani-Pedram, M
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2004, 49 (01): : 31 - 34
  • [28] Development of a nitrate ion-selective electrode based on an Urushi matrix membrane and its application to the direct measurement of nitrate-nitrogen in upland soils
    Ito, S
    Baba, K
    Asano, Y
    Takesako, H
    Wada, H
    TALANTA, 1996, 43 (11) : 1869 - 1881
  • [29] Preparation of gallium ion-selective membrane electrode by use of anion-exchange resin and its application to chemical analysis of industrial materials
    Yoshikuni, N
    Takeno, H
    Oguma, K
    BUNSEKI KAGAKU, 2001, 50 (11) : 753 - 757
  • [30] Preparation of a tellurium ion-selective membrane electrode using an anion-exchange resin and its application to chemical analysis of industrial materials
    Yoshikuni, N
    Nishiumi, S
    Oguma, K
    BUNSEKI KAGAKU, 2000, 49 (10) : 791 - 794