CLINICAL AND ANGIOGRAPHIC RESULTS OF BALLOON-EXPANDABLE INTRACORONARY STENTS IN RIGHT CORONARY-ARTERY STENOSES

被引:91
|
作者
LEVINE, MJ
LEONARD, BM
BURKE, JA
NASH, ID
SAFIAN, RD
DIVER, DJ
BAIM, DS
机构
[1] BETH ISRAEL HOSP,DEPT MED,DIV CARDIOVASC,HARVARD THORNDIKE LAB,330 BROOKLINE AVE,BOSTON,MA 02215
[2] CHARLES A DANA RES INST,BOSTON,MA
关键词
D O I
10.1016/0735-1097(90)90582-A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Balloon-expandable stents were placed successfully in 35 (95%) of 37 patients whose right coronary artery lesion was believed to have a poor short- or long-term prognosis with conventional balloon angioplasty because of prior restenosis or adverse lesion morphology. Quantitative angiography showed a reduction in stenosis diameter from 83 ± 14% to 42 ± 14% after conventional balloon dilation, with a further reduction to - 3 ± 12% after stent placement (p < 0.001). There were no acute stent thromboses, but one patient (with two stents and unstented distal disease) developed subacute thrombosis on day 8 after self-discontinuation of warfarin and was treated with thrombolytic therapy and reflation. Follow-up angiography was performed at 4 to 6 months in 25 patients, demonstrating restenosis (83 ± 13%) in 4 (57%) of 7 patients with multiple stents, but only 3 (17%) of 18 patients with a single stent (p < 0.05). Six of the seven in-stent restenotic lesions were subtotal (80 ± 12%) and were subjected to repeat conventional balloon angioplasty (postdilation stenosis 13 ± 21%). The 18 patients without restenosis had a maximal in-stent diameter stenosis of 29 ± 15%, corresponding to a maximal focal neointimal thickness of 0.68 ± 0.26 mm within the stented segment. These preliminary results suggest that the Schatz-Palmaz stent may be a useful adjunctive device in the performance of coronary angioplasty. © 1990.
引用
收藏
页码:332 / 339
页数:8
相关论文
共 50 条
  • [1] BALLOON-EXPANDABLE INTRACORONARY STENTS IN THE ADULT DOG
    SCHATZ, RA
    PALMAZ, JC
    TIO, FO
    GARCIA, F
    GARCIA, O
    REUTER, SR
    [J]. CIRCULATION, 1987, 76 (02) : 450 - 457
  • [2] MULTIVESSEL CORONARY INTERVENTION WITH A BALLOON-EXPANDABLE INTRACORONARY STENT
    CARROZZA, JP
    KUNTZ, RE
    FISHMAN, RF
    FRIEDRICH, S
    MILLER, MJ
    BAIM, DS
    [J]. CORONARY ARTERY DISEASE, 1992, 3 (05) : 403 - 406
  • [3] Balloon-expandable stents treat renal artery stenosis
    Al-Awqati, Q
    [J]. KIDNEY INTERNATIONAL, 2006, 69 (01) : 21 - 21
  • [4] TREATMENT OF ACUTE SYMPTOMATIC CORONARY DISSECTION WITH THE USE OF A BALLOON-EXPANDABLE INTRACORONARY STENT - CLINICAL AND ANGIOGRAPHIC FOLLOW-UP
    MUDRA, H
    HAUFE, MC
    KLAUSS, V
    METZ, J
    SPANNAGL, M
    THEISEN, K
    [J]. CORONARY ARTERY DISEASE, 1992, 3 (08) : 705 - 712
  • [5] INTRACORONARY STENTS - CLINICAL AND ANGIOGRAPHIC RESULTS
    POPMA, JJ
    ELLIS, SG
    [J]. HERZ, 1990, 15 (05) : 307 - 318
  • [6] ANGIOGRAPHIC MORPHOLOGY OF CORONARY-ARTERY STENOSES IN PROLONGED REST ANGINA - EVIDENCE OF INTRACORONARY THROMBOSIS
    REHR, R
    DISCIASCIO, G
    VETROVEC, G
    COWLEY, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (06) : 1429 - 1437
  • [7] BALLOON DILATATION AND BALLOON-EXPANDABLE STENTS FOR PTA OF PROXIMAL VENOUS STENOSES IN HEMODIALYSIS-PATIENTS
    LANDWEHR, P
    LACKNER, K
    GOTZ, R
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (03): : 239 - 245
  • [8] CLINICAL AND ANGIOGRAPHIC OUTCOMES AFTER CORONARY-ARTERY STENTING FOR ACUTE OR THREATENED CLOSURE AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - INITIAL RESULTS WITH A BALLOON-EXPANDABLE, STAINLESS-STEEL DESIGN
    HEARN, JA
    KING, SB
    DOUGLAS, JS
    CARLIN, SF
    LEMBO, NJ
    GHAZZAL, ZMB
    [J]. CIRCULATION, 1993, 88 (05) : 2086 - 2096
  • [9] Treatment of pulmonary artery pseudoaneurysms and stenosis with balloon-expandable stents
    Imrie, Andrew
    Haran, Crishan, V
    Trotter, Michael
    Bell, Brendan
    Brown, Nicholas, I
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2022, 66 (07) : 969 - 976
  • [10] EMERGENT USE OF BALLOON-EXPANDABLE CORONARY-ARTERY STENTING FOR FAILED PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    HERRMANN, HC
    BUCHBINDER, M
    CLEMEN, MW
    FISCHMAN, D
    GOLDBERG, S
    LEON, MB
    SCHATZ, RA
    TIERSTEIN, P
    WALKER, CM
    HIRSHFELD, JW
    [J]. CIRCULATION, 1992, 86 (03) : 812 - 819