STAY-CABLE FATIGUE BEHAVIOR

被引:30
|
作者
STALLINGS, JM [1 ]
FRANK, KH [1 ]
机构
[1] UNIV TEXAS,DEPT CIVIL ENGN,AUSTIN,TX 78712
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 1991年 / 117卷 / 03期
关键词
D O I
10.1061/(ASCE)0733-9445(1991)117:3(936)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Monte Carlo simulation is used to investigate the relationship between the fatigue lives of short-prestressing strand test specimens and strand stay cables. Cable lives are calculated using statistics determined from the results of fatigue tests of prestressing strand specimens. The cable modeling accounts for the effects of cable length and the number of cable strands on the fatigue life. Three different probability distributions are used to characterize the scatter in the fatigue lives of strand test specimens. Comparisons are made between cable lives calculated using each of the distributions. The predicted cable life is found to be sensitive to the distribution that is used. The distributions produce similar conclusions concerning the relationship between cable length, number of strands, and cable-fatigue life with the short test specimen behavior.
引用
收藏
页码:936 / 950
页数:15
相关论文
共 50 条
  • [21] STAY CABLE FATIGUE DESIGN LOADING
    GOODYEAR, WD
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1987, 32 (03): : 36 - 51
  • [22] Experimental study on aerodynamic control measures for vortex-induced vibration of stay-cable
    Liu Z.-W.
    Shen J.-S.
    Chen Z.-Q.
    Wang J.-M.
    Feng L.-P.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2021, 34 (03): : 441 - 451
  • [23] Fully automated peak-picking method for an autonomous stay-cable monitoring system in cable-stayed bridges
    Jin, Seung-Seop
    Jeong, Seunghoo
    Sim, Sung-Han
    Seo, Dong-Woo
    Park, Young-Soo
    AUTOMATION IN CONSTRUCTION, 2021, 126 (126)
  • [24] Automated Real-Time Assessment of Stay-Cable Serviceability Using Smart Sensors
    Jeong, Seunghoo
    Lee, Young-Joo
    Shin, Do Hyoung
    Sim, Sung-Han
    APPLIED SCIENCES-BASEL, 2019, 9 (20):
  • [25] In-plane and out-of-plane vibration suppression of stay-cable by viscous dampers
    Lou, WJ
    Chen, SS
    Sun, BN
    SMART STRUCTURES AND MATERIALS 2003: DAMPING AND ISOLATION, 2003, 5052 : 421 - 432
  • [26] Investigating the use of Targeted-Energy-Transfer devices for stay-cable vibration mitigation
    Izzi, Matteo
    Caracoglia, Luca
    Noe, Salvatore
    STRUCTURAL CONTROL & HEALTH MONITORING, 2016, 23 (02): : 315 - 332
  • [27] The MaChang bridge in South Korea - Stay-cable bridge with steel composite deck for highway traffic
    Hopf, Siegfried
    Patsch, Armin
    Walser, Peter
    STAHLBAU, 2008, 77 (07) : 498 - 506
  • [28] Monitoring of stay-cable icing based on electro-mechanical impedance and principal component analysis
    Zhang X.
    Sun X.
    Zhou W.
    Zhang Y.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2020, 41 (12): : 1765 - 1771
  • [29] STAY CABLE FATIGUE DESIGN LOADING.
    Goodyear, W.David
    1600, (32):
  • [30] Impact of Wind Load Characteristics on Computed Bridge Stay-Cable Forces Used for Bridge Health Monitoring
    Chen, Jian
    Chajes, Michael J. J.
    Shenton III, Harry W. W.
    JOURNAL OF BRIDGE ENGINEERING, 2023, 28 (04)