MEASUREMENT OF NET FLUXES OF AMMONIUM AND NITRATE AT THE SURFACE OF BARLEY ROOTS USING ION-SELECTIVE MICROELECTRODES

被引:53
|
作者
HENRIKSEN, GH [1 ]
BLOOM, AJ [1 ]
SPANSWICK, RM [1 ]
机构
[1] UNIV CALIF DAVIS,DEPT VEGETABLE CROPS,DAVIS,CA 95616
关键词
D O I
10.1104/pp.93.1.271
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Neutral carrier-based liquid membrane ion-selective microelectrodes for NH4+ and NO3- were developed and used to investigate inorganic nitrogen acquisition in two varieties of barley, Hordeum vulgare L. cv Olli and H. vulgare L. cv Prato, originating in cold and warm climates, respectively. In the present paper, the methods used in the fabrication of ammonium- and nitrate-selective microelectrodes are described, and their application in the study of inorganic nitrogen uptake is demonstrated. Net ionic fluxes of NH4+ and NO3- were measured in the unstirred layer of solution immediately external to the root surface. The preference for the uptake of a particular ionic form was examined by measuring the net flux of the predominant form of inorganic nitrogen, with and without the alternative ion in solution. Net flux of NH4+ into the cold-adapted variety remained unchanged when equimolar concentrations (200 micromolar) of NH4+ and NO3- were present. Similarly, net flux of NO3- into the warm-adapted variety was not affected when NH4+ was also present in solution. The high temporal and spatial resolution afforded by ammonium- and nitrateselective microelectrodes permits a detailed examination of inorganic nitrogen acquisition and its component ionic interactions.
引用
收藏
页码:271 / 280
页数:10
相关论文
共 50 条
  • [31] Simultaneous measurement of ammonium, nitrate and proton fluxes along the length of eucalypt roots
    Garnett, TP
    Shabala, SN
    Smethurst, PJ
    Newman, IA
    PLANT AND SOIL, 2001, 236 (01) : 55 - 62
  • [32] Comparison of ion-selective and carbon fiber mercury film microelectrodes for cadmium measurement
    Jin, Peng
    Bishop, Paul L.
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2007, 133 (06): : 608 - 615
  • [33] MEASUREMENT OF INTRACELLULAR NITRATE CONCENTRATIONS IN CHARA USING NITRATE-SELECTIVE MICROELECTRODES
    MILLER, AJ
    ZHEN, RG
    PLANTA, 1991, 184 (01) : 47 - 52
  • [34] NITRATE DETERMINATION IN BABY FOOD, USING NITRATE ION-SELECTIVE ELECTRODE
    PFEIFFER, SL
    SMITH, J
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1975, 58 (05): : 915 - 919
  • [35] SIMULTANEOUS MEASUREMENT OF INTRACELLULAR PH AND K+ OR NO3- IN BARLEY ROOT-CELLS USING TRIPLE-BARRELED, ION-SELECTIVE MICROELECTRODES
    WALKER, DJ
    SMITH, SJ
    MILLER, AJ
    PLANT PHYSIOLOGY, 1995, 108 (02) : 743 - 751
  • [36] Measurements of net fluxes and extracellular changes of H+, Ca2+, K+, and NH4+ in Escherichia coli using ion-selective microelectrodes
    Shabala, L
    Ross, T
    Newman, I
    McMeekin, T
    Shabala, S
    JOURNAL OF MICROBIOLOGICAL METHODS, 2001, 46 (02) : 119 - 129
  • [37] POTASSIUM HOMEOSTASIS IN BARLEY ROOT-CELLS - MEASUREMENTS WITH TRIPLE-BARRELED ION-SELECTIVE MICROELECTRODES
    MILLER, AJ
    WALKER, DJ
    LEIGH, RA
    JOURNAL OF CELLULAR BIOCHEMISTRY, 1995, : 152 - 152
  • [38] SCHISTOSOMA-MANSONI - MEASUREMENT OF NA+ ION ACTIVITY IN THE TEGUMENT AND THE EXTRACELLULAR-SPACES USING ION-SELECTIVE MICROELECTRODES
    PAX, RA
    CHEN, GZ
    BENNETT, JL
    EXPERIMENTAL PARASITOLOGY, 1987, 64 (02) : 219 - 227
  • [39] Aptamer-based potentiometric measurements of proteins using ion-selective microelectrodes
    Numnuam, Apon
    Chumbimuni-Torres, Karin Y.
    Xiang, Yun
    Bash, Ralph
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Pretsch, Ernoe
    Wang, Joseph
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2008, 80 (03) : 707 - 712
  • [40] Monitoring Ion Activities In and Around Cells Using Ion-Selective Liquid-Membrane Microelectrodes
    Lee, Seong-Ki
    Boron, Walter F.
    Parker, Mark D.
    SENSORS, 2013, 13 (01): : 984 - 1003