A prospective study to evaluate and compare laryngeal mask airway ProSeal and i-gel airway in the prone position

被引:11
|
作者
Taxak, Susheela [1 ]
Gopinath, Ajith [1 ]
Saini, Savita [1 ]
Bansal, Teena [1 ]
Ahlawat, Mangal Singh [1 ]
Bala, Manju [1 ]
机构
[1] Pt BD Sharma Univ Hlth Sci, Dept Anesthesiol & Crit Care, Rohtak, Haryana, India
关键词
Anesthesia; i-gel; prone position; ProSeal laryngeal mask airway; supraglottic airway device;
D O I
10.4103/1658-354X.159473
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Prone position is commonly used to provide surgical access to a variety of surgeries. In view of the advantages of induction of anesthesia in the prone position, we conducted a randomized study to evaluate and compare ProSeal laryngeal mask airway (LMA) and i-gel in the prone position. Materials and Methods: Totally, 40 patients of either sex as per American Society of Anesthesiologists physical status I or II, between 16 and 60 years of age, scheduled to undergo surgery in prone position were included in the study. After the patients positioned themselves prone on the operating table, anesthesia was induced by the standard technique. LMA ProSeal was used as an airway conduit in group 1 while i-gel was used in group 2. At the end of surgery, the airway device was removed in the same position. Results: Insertion of airway device was successful in first attempt in 16, and 17 cases in ProSeal laryngeal mask airway (PLMA) and i-gel groups, respectively. A second attempt was required to secure the airway in 4 and 3 patients in PLMA and i-gel groups, respectively. The mean insertion time was 21.8 2.70 s for group 1 and 13.1 2.24 s for group 2, the difference being statistically significant (P < 0.05). The mean seal pressure in group 1 was 36 6.22 cm H 2 O and in group 2 was 25.4 3.21 cm H 2 O. The difference was statistically significant (P < 0.05). 13 patients in group 1 had fiberoptic bronchoscopy (FOB) grade 1 while it was 6 for group 2. The remaining patients in both groups had FOB grade 2. Conclusion: Insertion of supraglottic airways and conduct of anesthesia with them is feasible in the prone position. The PLMA has a better seal while insertion is easier with i-gel.
引用
收藏
页码:446 / 450
页数:5
相关论文
共 50 条
  • [1] A randomised trial to compare i-gel and ProSeal (TM) laryngeal mask airway for airway management in paediatric patients
    Nirupa, R.
    Gombar, Satinder
    Ahuja, Vanita
    Sharma, Preeti
    INDIAN JOURNAL OF ANAESTHESIA, 2016, 60 (10) : 726 - 731
  • [2] The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients
    Shin, Won-Jung
    Cheong, Yu-Seon
    Yang, Hong-Seuk
    Nishiyama, Tomoki
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) : 598 - 601
  • [3] COMPARISON OF SUPRAGLOTTIC AIRWAY DEVICE I-GEL WITH CLASSIC LARYNGEAL MASK AIRWAY AND PROSEAL LARYNGEAL MASK AIRWAY FOR SHORT SURGICAL PROCEDURES
    Gandhi, Monika
    Arora, K. K.
    Sharma, Akansha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (18): : 2222 - 2226
  • [4] A RANDOMIZED COMPARISON OF THE I-GEL WITH THE PROSEAL LARYNGEAL MASK AIRWAY IN PEDIATRIC PATIENTS
    Fukuhara, A.
    Okutani, R.
    Oda, Y.
    ANESTHESIA AND ANALGESIA, 2012, 114
  • [5] An unusual case of airway rescue in the prone position with the ProSeal laryngeal mask airway
    Brimacombe, J
    Keller, C
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (08): : 884 - 884
  • [6] An unusual case of airway rescue in the prone position with the ProSeal laryngeal mask airway
    Joseph Brimacombe
    Christian Keller
    Canadian Journal of Anesthesia, 2005, 52 : 884 - 884
  • [7] Airway morbidity after use of the laryngeal mask airway: LMA ProSeal® vs. i-gel®
    Soliveres, J.
    Balaguer, J.
    Richart, M. T.
    Sanchez, J.
    Solaz, C.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 257 - 258
  • [8] Comparison between i-gel airway an the proseal laryngeal mask airway in pediatric patients undergoing general anesthesia
    Acharya, R.
    Dave, N. M.
    PEDIATRIC ANESTHESIA AND CRITICAL CARE JOURNAL, 2016, 4 (02): : 97 - 102
  • [9] A randomized study to compare ProSeal laryngeal mask airway with classic laryngeal mask airway in anesthetized patients
    Taxak, Susheela
    Kaur, Kiranpreet
    Kaushik, Shubham
    Singh, Rita
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2013, 29 (04) : 285 - 290
  • [10] Pulmonary aspiration associated with supraglottic airways: Proseal laryngeal mask airway and I-Gel(TM)
    Kim, Yoon-Hee
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 63 (06) : 489 - 490