A randomized study to compare ProSeal laryngeal mask airway with classic laryngeal mask airway in anesthetized patients

被引:4
|
作者
Taxak, Susheela [1 ]
Kaur, Kiranpreet [1 ]
Kaushik, Shubham [1 ]
Singh, Rita
机构
[1] Pt BD Sharma Pgims, Dept Anaesthesiol & Crit Care, Rohtak 124001, Haryana, India
关键词
PLMA; LMA; Airway sealing pressure; Fiber-optic scoring; Insertion time;
D O I
10.1016/j.egja.2013.05.009
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: To overcome the problem of gastric content regurgitation, a device with drain tube and better airway sealing has been made: the ProSeal laryngeal mask airway (PLMA). We aimed to compare the clinical performance of the classic LMA with the PLMA. Several studies comparing these two devices have been done. Our study was designed to compare ease of insertion, airway sealing pressure, and fiber-optic assessment of positioning in adult patients, and we hopes to prove that PLMA is better to LMA in all these aspects. We hypothesized that PLMA would have a better leak pressure than the CLMA and minimum difference in leak pressure of 20% between them was considered clinically significant. Material and methods: One hundred adult patients of either sex between age group of 18-65 years scheduled for elective surgery were included in the study. Patients were randomly allocated to two groups of 50 patients each. In group I CLMA and in group II PLMA were used. The number of attempts, ease of insertion, time of insertion, and failure if occurred were noted down. Hemodynamic changes, airway sealing pressure, and the fiber-optic were also recorded. Results: Data thus compiled showed that insertion was successful in first attempt in 94% cases with LMA as well as PLMA. The time taken for successful placement of LMA and - PLMA was 15 and 17 s, respectively. Sealing pressure was higher for group II at all cuff volumes. More number of patients (89%) in group II had a fiber optic score of I and II as compared to group I which had 81% patients with score I and II. Conclusion: We conclude that PLMA is easy to insert with a short insertion time, high success of placement at first attempt, and capable of achieving a more effective seal than LMA. (C) 2013 Production and hosting by Elsevier B.V. on behalf of Egyptian Society of Anesthesiologists.
引用
收藏
页码:285 / 290
页数:6
相关论文
共 50 条
  • [1] The ProSeal laryngeal mask airway - A randomized, crossover study with the standard laryngeal mask airway in paralyzed, anesthetized patients
    Brimacombe, J
    Keller, C
    [J]. ANESTHESIOLOGY, 2000, 93 (01) : 104 - 109
  • [2] Proseal Laryngeal mask airway or Classic Laryngeal mask airway in spontaneous ventilation?
    Galarioti, V.
    Michaloliakou, Ch.
    Kalanzi, N.
    Pagoulatou, A.
    Andrianopoulou, A.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 68 - 68
  • [3] A RANDOMIZED CROSSOVER COMPARISON OF THE LARYNGEAL MASK AIRWAY PROSEAL AND LARYNGEAL MASK AIRWAY SUPREME IN ANESTHETIZED ADULT PATIENTS
    Jannu, Vinayaka
    Dhorigol, M. G.
    Sanikop, C. S.
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (85): : 14828 - 14833
  • [4] The Size 1 ProSeal™ laryngeal mask airway in infants: a randomized, noncrossover study with the Classic™ laryngeal mask airway
    Lopez-Gil, Maite
    Mantilla, Ignacio
    Blanco, Teresa
    Teigell, Enrique
    Hervias, Monica
    Fernandez-Lopez, Rosa
    [J]. PEDIATRIC ANESTHESIA, 2012, 22 (04) : 365 - 370
  • [5] A comparison of the Supreme™ laryngeal mask airway with the Proseal™ laryngeal mask airway in anesthetized paralyzed adult patients: a randomized crossover study
    Tham, Huae Min
    Tan, Su Meng
    Woon, Kwee Lian
    Zhao, Yu Dong
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2010, 57 (07): : 672 - 678
  • [6] A multicenter study comparing the ProSeal™ and Classic™ laryngeal mask airway in anesthetized, nonparalyzed patients
    Brimacombe, J
    Keller, C
    Fullekrug, B
    Agrò, F
    Rosenblatt, W
    Dierdorf, SF
    de Lucas, EG
    Capdevilla, X
    Brimacombe, N
    [J]. ANESTHESIOLOGY, 2002, 96 (02) : 289 - 295
  • [7] The size 11/2 ProSeal™ laryngeal mask airway in infants:: A randomized, crossover investigation with the Classic™ laryngeal mask airway
    Goldmann, K
    Roettger, C
    Wulf, H
    [J]. ANESTHESIA AND ANALGESIA, 2006, 102 (02): : 405 - 410
  • [8] The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients
    Shin, Won-Jung
    Cheong, Yu-Seon
    Yang, Hong-Seuk
    Nishiyama, Tomoki
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) : 598 - 601
  • [9] Comparison of the standard laryngeal mask airway and the ProSeal laryngeal mask airway in obese patients
    Natalini, G
    Franceschetti, ME
    Pantelidi, MT
    Rosano, A
    Lanza, G
    Bernardini, A
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (03) : 323 - 326
  • [10] The ProSeal laryngeal mask airway
    Dalgleish, DJ
    Dolgner, M
    [J]. ANAESTHESIA, 2001, 56 (10) : 1010 - 1010