Predictive value of preintervention C-reactive protein on clinical outcome after directional coronary atherectomy followed by stent implantation

被引:4
|
作者
Niccoli, Giampaolo [1 ]
Ferrante, Giuseppe [1 ]
Mongiardo, Rocco [1 ]
Perfetti, Matteo [1 ]
Belloni, Flavia [1 ]
Burzotta, Francesco [1 ]
Porto, Italo [1 ]
Leone, Antonio Maria [1 ]
Rebuzzi, Antonio G. [1 ]
Crea, Filippo [1 ]
机构
[1] Univ Cattolica Sacro Cuore, Inst Cardiol, Rome, Italy
关键词
C-reactive protein; Directional coronary atherectomy; Prognosis;
D O I
10.1016/j.carrev.2007.02.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Preprocedural C-reactive protein (CRP) serum levels have been shown to predict the recurrence of angina or major adverse cardiac events after percutaneous coronary intervention. Directional coronary atherectomy (DCA), by reducing residual plaque burden and restenosis, has been shown to improve clinical outcome after coronary stenting. Thus, we assessed the influence of preprocedural CRP serum levels on the recurrence of cardiac events after DCA followed by bare metal stent implantation. Methods: We enrolled 40 consecutive patients (34 males; 61 +/- 10 years old) with single-vessel disease who were undergoing DCA. In all patients, preprocedural CRP serum levels were measured by an ultrasensitive nephelometric method. The endpoint of the study was defined as the composite incidence of death, myocardial infarction, and recurrence of angina requiring repeat revascularization at 6-month follow-up. Results: CRP serum levels were a significant independent predictor of the composite endpoint at multiple regression analysis [odds ratio=1.69; 95% confidence interval (95% CI)=1.04-2.75; P=.033]. Patients with recurrence of cardiac events had CRP serum levels higher than those of patients not having events on follow-up [3.95 (2.2-5.7) vs. 2 (1.3-3.3); P=.05]. Conclusion: In conclusion, our study shows that baseline CRP serum levels predict cardiac events after coronary bare metal stenting despite plaque debulking with directional atherectomy. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:156 / 160
页数:5
相关论文
共 50 条
  • [21] Clinical and angiographic outcome of directional atherectomy followed by stent implantation in de novo lesions located at the ostium of the left anterior descending coronary artery
    Airoldi, F
    Di Mario, C
    Stankovic, G
    Briguori, C
    Carlino, M
    Chieffo, A
    Liistro, F
    Montorfano, M
    Pagnotta, P
    Spanos, V
    Tavano, D
    Colombo, A
    HEART, 2003, 89 (09) : 1050 - 1054
  • [22] Increased C-reactive protein level after coronary stent implantation in patients with stable coronary artery disease
    Almagor, M
    Keren, A
    Banai, S
    AMERICAN HEART JOURNAL, 2003, 145 (02) : 248 - 253
  • [23] Increased C-reactive protein plasma levels after coronary stent implantation in stable angina pectoris patients are not related to 6 months clinical outcome
    Ziakas, A
    Gavrielidis, S
    Chatzimiltiadis, S
    Gourasas, J
    Karoulas, D
    Louridas, G
    EUROPEAN HEART JOURNAL, 2001, 22 : 655 - 655
  • [24] C-reactive protein in hypertension: clinical significance and predictive value
    Schillaci, Giuseppe
    Pirro, Matteo
    NUTRITION METABOLISM AND CARDIOVASCULAR DISEASES, 2006, 16 (07) : 500 - 508
  • [25] C-REACTIVE PROTEIN FOR PREDICTING CLINICAL OUTCOMES AFTER DRUG-ELUTING STENT IMPLANTATION
    Yu Miao
    Zhou Yujie
    Wang Zhijian
    Shi Dongmei
    Liu Yuyang
    Zhao Yingxin
    Guo Yonghe
    HEART, 2010, 96 : A130 - A130
  • [26] The efficacy of sirolimus-eluting stent implantation after directional coronary atherectomy
    Chen, Po-Min
    Hiasa, Yoshikazu
    Tobetto, Yohei
    Miyazaki, Shinichiro
    Mahara, Keitaro
    Ogura, Riyo
    Miyajima, Hitoshi
    Yuba, Kenichiro
    Suzuki, Naoki
    Takahashsi, Takefumi
    Hosokawa, Shinobu
    Kishi, Koichi
    Otani, Ryuji
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 122 : 108 - 109
  • [27] Elevated C-reactive protein level after coronary stent implantation in patients with stable angina pectoris
    Hikita, H.
    Sato, A.
    Nozato, T.
    Kawashima, T.
    Miyazaki, T.
    Tamura, M.
    Ohhigashi, H.
    Isobe, M.
    Hiroe, M.
    Takahashi, A.
    EUROPEAN HEART JOURNAL, 2008, 29 : 656 - 656
  • [28] Predictive value of preinterventional C-reactive protein levels on angiographic restenosis and cardiac events after Sirolimus-eluting stent implantation
    Inoue, Keiji
    Kitamura, Makoto
    Fujita, Hiroshi
    Tanaka, Telsuya
    Matsuo, Akiko
    Nishibori, Yoshiharu
    Yamaguchi, Shinichiro
    Nakanishi, Naohiko
    Shiono, Yaslitsugu
    Matsuo, Kiyonari
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A263 - A263
  • [29] Inhibition of C-reactive protein after implantation of a sirolimus-eluting stent
    Bueb, JL
    Tschirhart, E
    Gilson, G
    Beissel, J
    Vaillant, M
    Autier, P
    Wagner, DR
    FRONTIERS IN CORONARY ARTERY DISEASE, 2003, : 673 - 678
  • [30] Angiotensin-converting enzyme insertion/deletion polymorphism and risk of restenosis after directional coronary atherectomy followed by stent implantation
    Canosi, U
    Merlini, PA
    Bernardi, F
    Repetto, A
    Bramucci, E
    Ferrario, M
    Angoli, L
    Gnecchi, M
    Ferraresi, P
    Marchetti, G
    Tavazzi, L
    Ardissino, D
    THROMBOSIS AND HAEMOSTASIS, 2004, 91 (04) : 795 - 800