In situ seismic testing of a reinforced autoclaved aerated concrete building

被引:4
|
作者
Binici, Baris [1 ]
Gokmen, Furkan [1 ]
Canbay, Erdem [1 ]
Aldemir, Alper [2 ]
Ogdu, Mustafa Kagan [3 ]
Uzgan, Ugur [3 ]
Eryurtlu, Zafer [3 ]
Ozdemir, Gulay [4 ]
机构
[1] Middle East Tech Univ, Univ Mah, Ankara, Turkey
[2] Hacettepe Univ, Beytepe Mahallesi, Ankara, Turkey
[3] AKG Gazbeton, Bahsili, Kirikkale, Turkey
[4] Turkish AAC Assoc, Kuzgun Sokak, Ankara, Turkey
关键词
design; drift; in situ testing; reinforced wall panel; seismic;
D O I
10.1002/dama.201800020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Autoclaved aerated concrete (AAC) reinforced panels are used to construct easily erected, energy efficient, low-rise prefabricated buildings. This study aims to contribute to the understanding of the seismic response of reinforced-AAC-wall-panel buildings. For this purpose, a full-scale two-story building constructed on a building site by using reinforced AAC panels was tested under two-way cyclic displacement excursions up to near collapse. The test results showed that the test building had a lateral load capacity of 1.6 times its weight with a global displacement ductility of about 3.5. The first story of the building sustained significant damage due to the rocking of the building followed by panel crushing. The slab-wall connections did not sustain any damage during the test. Afterward, numerical models of AAC panels were calibrated by using component test results from the literature. Nonlinear static analysis was conducted on the test building by using the proposed modeling approach. A reasonably good agreement was observed between the test results and numerical model estimations both for the envelope and the cyclic response. Finally, incremental dynamic analyses were conducted on the test building in order to observe the response of the building under severe earthquake motions. The dynamic analyses results showed that AAC buildings are expected to behave in their pre-yielding regions under design earthquakes. Furthermore, the reserved ductility and available over strength can enable AAC buildings survive the maximum considered earthquakes without collapse.
引用
收藏
页码:305 / 313
页数:9
相关论文
共 50 条
  • [21] Lattice modeling and testing of aerated autoclaved concrete infilled frames
    Aydin, Beyazit B.
    Binici, Baris
    Hendriks, Max A. N.
    Tuncay, Kagan
    [J]. ENGINEERING STRUCTURES, 2022, 251
  • [22] The carbonation of autoclaved aerated concrete
    Hanecka, K
    Koronthalyova, O
    Matiasovsky, P
    [J]. CEMENT AND CONCRETE RESEARCH, 1997, 27 (04) : 589 - 599
  • [23] The durability of autoclaved aerated concrete
    Straube, Berit
    Schoch, Torsten
    [J]. MAUERWERK, 2014, 18 (3-4) : 239 - 245
  • [24] Durability of autoclaved aerated concrete
    Bohner, E
    Ödeen, K
    [J]. DURABILITY OF BUILDING MATERIALS AND COMPONENTS 8, VOLS 1-4, PROCEEDINGS, 1999, : 107 - 117
  • [25] Experimental Study on Shear Behavior of Reinforced Autoclaved Aerated Concrete Slab
    Zhang, Tianjun
    Dai, Jinzhen
    Qin, Shihong
    [J]. 2020 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL, AUTOMATION AND MECHANICAL ENGINEERING, 2020, 1626
  • [26] Numerical simulations for autoclaved aerated concrete (AAC) masonry modules reinforced with columns of disperse reinforced concrete
    Iernutan, Razvan Andrei
    Babota, Florin
    [J]. 12TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING (INTER-ENG 2018), 2019, 32 : 908 - 915
  • [27] Historical defects in buildings No. 1: Reinforced autoclaved aerated concrete
    Docherty, Hugh
    [J]. Structural Engineer, 2023, 101 (10): : 18 - 19
  • [28] Analysis of lightweight composite sections with reinforced concrete infill with autoclaved aerated concrete (AAC)
    Okasha, Mostafa Ali Taha Ali
    Razek, Mohamed Abdel
    El-Esnawi, Hassan
    Alkhatib, Soliman
    [J]. FRONTIERS IN BUILT ENVIRONMENT, 2023, 9
  • [29] Design and seismic testing of two-story, full-scale autoclaved aerated concrete assemblage specimen
    Tanner, JE
    Varela, JL
    Klingner, RE
    [J]. ACI STRUCTURAL JOURNAL, 2005, 102 (01) : 114 - 119
  • [30] Mechanical and microstructural features of autoclaved aerated concrete reinforced with autoclaved polypropylene, carbon, basalt and glass fiber
    Pehlivanli, Zuhtu Onur
    Uzun, Ibrahim
    Demir, Ilhami
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2015, 96 : 428 - 433