COMPARISON OF ST-JUDE-MEDICAL (SMJ) HANCOCK (H) AND CARPENTIER-EDWARDS (CE) VALVES IN AN AORTIC POSITION IN PULSE DUPLICATOR

被引:0
|
作者
HANCOCK, H [1 ]
CARPENTIER, E [1 ]
机构
[1] KERCKHOFF KLIN,D-6350 BAD NAUHEIM,FED REP GER
来源
ZEITSCHRIFT FUR KARDIOLOGIE | 1982年 / 71卷 / 03期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:235 / 235
页数:1
相关论文
共 48 条
  • [41] Effect of heart rate on the hemodynamics of bileaflet mechanical heart valves' prostheses (St. Jude Medical) in the aortic position and in the opening phase: A computational study
    Jahandardoost, Mehdi
    Fradet, Guy
    Mohammadi, Hadi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (03) : 175 - 190
  • [42] Comprehensive Hemodynamic Comparison and Frequency of Patient-Prosthesis Mismatch between the St. Jude Medical Trifecta and Epic Bioprosthetic Aortic Valves
    Yadlapati, Ajay
    Diep, Jimmy
    Barnes, MaryJo
    Grogan, Tristan
    Bethencourt, Daniel M.
    Vorobiof, Gabriel
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (06) : 581 - 589
  • [43] 3-DIMENSIONAL VISUALIZATION OF VELOCITY PROFILES IN THE ASCENDING AORTA IN HUMANS - A COMPARATIVE-STUDY AMONG NORMAL AORTIC VALVES, ST-JUDE MEDICAL AND STARR-EDWARDS SILASTIC BALL VALVES
    PAULSEN, PK
    HASENKAM, JM
    STODKILDEJORGENSEN, H
    ALBRECHTSEN, O
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1988, 11 (04): : 277 - 292
  • [45] Doppler echocardiographic comparison of standard versus the haemodynamic-plus St Jude Medical Valve in aortic position: a population-based study
    Mohty, D
    Girard, SGSE
    Malouf, YMYF
    Schaff, HSHV
    Sarano, MESME
    Miller, FAMFA
    EUROPEAN HEART JOURNAL, 2002, 23 : 365 - 365
  • [46] LONG-TERM PERFORMANCE OF STARR-EDWARDS SILASTIC BALL VALVES AND ST JUDE MEDICAL BI-LEAFLET VALVES - A COMPARATIVE-ANALYSIS OF IMPLANTATIONS DURING 1980-86 FOR AORTIC-STENOSIS
    LUND, O
    KNUDSEN, MA
    PILEGAARD, HK
    MAGNUSSEN, K
    NIELSEN, TT
    EUROPEAN HEART JOURNAL, 1990, 11 (02) : 108 - 119
  • [47] Mid-term results of 17-mm St. Jude Medical Regent prosthetic valves in elder patients with small aortic annuli: comparison with 19-mm bioprosthetic valves
    Hideki Teshima
    Masahiko Ikebuchi
    Toshikazu Sano
    Ryuta Tai
    Naohiro Horio
    Hiroyuki Irie
    Journal of Artificial Organs, 2014, 17 : 258 - 264
  • [48] Mid-term results of 17-mm St. Jude Medical Regent prosthetic valves in elder patients with small aortic annuli: comparison with 19-mm bioprosthetic valves
    Teshima, Hideki
    Ikebuchi, Masahiko
    Sano, Toshikazu
    Tai, Ryuta
    Horio, Naohiro
    Irie, Hiroyuki
    JOURNAL OF ARTIFICIAL ORGANS, 2014, 17 (03) : 258 - 264