TEST OF LONG SCINTILLATION-COUNTERS FOR SUPERCOLLIDER DETECTORS

被引:12
|
作者
BELLAMY, EH
BELLETTINI, G
BUDAGOV, J
CERVELLI, F
CHIRIKOVZORIN, I
KOVTUN, V
INCAGLI, M
LUCCHESI, D
PAGLIARONE, C
PUKHOV, O
SEMINOZHENKO, V
SENCHISHIN, V
TOKAR, S
VEREZUB, N
ZALJUBOVSKY, I
ZETTI, F
机构
[1] UNIV PISA,DIPARTIMENTO FIS,I-56100 PISA,ITALY
[2] IST NAZL FIS NUCL,SEZ PISA,PISA,ITALY
[3] SUPERCONDUCTING SUPER COLLIDER LAB,DALLAS,TX
[4] DUBNA JOINT NUCL RES INST,DUBNA,RUSSIA
[5] KHARKOV AM GORKII STATE UNIV,KHARKOV,UKRAINE
[6] STC INST MONOCRYSTAL SA UKRAINE,KHARKOV,UKRAINE
[7] COMENIUS UNIV BRATISLAVA,CS-80100 BRATISLAVA,SLOVAKIA
[8] POLYTECH INST,KHARKOV,UKRAINE
关键词
D O I
10.1016/0168-9002(94)90228-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A number of long scintillator counters employing UPS 923A and NE 114 plastic scintillators seen by a single photomultiplier were tested using cosmic muons. These counters have suitable dimensions to be used in large arrays in a proton supercollider experiment. The efficiency for m.i.p. was excellent in all cases. The yield of UPS 923A was found to be by about 25% higher than NE 114, while the attenuation length was approximately the same.
引用
收藏
页码:484 / 488
页数:5
相关论文
共 50 条
  • [21] APPLICATIONS OF LOW-LEVEL LIQUID SCINTILLATION-COUNTERS
    KESSLER, MJ
    APPLIED RADIATION AND ISOTOPES, 1988, 39 (06) : 592 - 592
  • [22] ACCURATE TIME MEASUREMENTS WITH PLASTIC SCINTILLATION-COUNTERS
    BINON, F
    BRICMAN, C
    DUTEIL, P
    GOUANERE, M
    JANSEN, J
    LAGNAUX, JP
    PEIGNEUX, JP
    SILLOU, D
    SPIGHEL, M
    STROOT, JP
    VILAIN, P
    NUCLEAR INSTRUMENTS & METHODS, 1978, 153 (2-3): : 409 - 412
  • [23] BASIC LIMITATION OF SCINTILLATION-COUNTERS IN TIME MEASUREMENTS
    LYNCH, FJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 58 - 64
  • [24] TIME STATISTICS OF THE PHOTOELECTRON EMISSION PROCESS IN SCINTILLATION-COUNTERS
    RANUCCI, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2): : 121 - 128
  • [25] HOW MUCH LIGHT FROM RECTANGULAR SCINTILLATION-COUNTERS
    SMITH, T
    PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (02): : 282 - 295
  • [26] TIME-REFERENCING DEVICE FOR LARGE SCINTILLATION-COUNTERS
    BOREIKO, VF
    GREBENYUK, VM
    ZINOV, VG
    IVANOV, VV
    KOZHEVNIKOV, YA
    STOLETOV, GD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1987, 30 (05) : 1109 - 1112
  • [27] COMPARISON OF INSTRUMENT PERFORMANCE FOR 6 LIQUID SCINTILLATION-COUNTERS
    PATTERSON, JF
    SAUERBRUNN, BJL
    BATTIST, L
    ANALYTICAL BIOCHEMISTRY, 1978, 86 (02) : 707 - 715
  • [28] SILICON PHOTODIODES AS PHOTOMULTIPLIER REPLACEMENTS IN INDUSTRIAL SCINTILLATION-COUNTERS
    ASGHAR, M
    IMRIE, DC
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (12): : 1012 - 1015
  • [29] VERY LARGE AREA SCINTILLATION-COUNTERS FOR HADRON CALORIMETRY
    BARISH, B
    BODEK, A
    CHU, YK
    KLEINKNECHT, K
    LEE, J
    LINSAY, PS
    LUDWIG, J
    SCIULLI, F
    SHAEVITZ, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 532 - 536
  • [30] SCINTILLATION-COUNTERS CHARACTERISTICS VERSUS LIGHT COLLECTION CONDITIONS
    IGNATENKO, MA
    STOLETOV, GD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1994, 37 (04) : 407 - 411