INFLUENCE OF BIOLOGICAL RESPONSE MODIFIERS - MEASUREMENT OF TUMOR BLOOD-FLOW AND TEMPERATURE

被引:9
|
作者
LI, J
MERTON, DA
THAKUR, ML
BARR, J
WILDER, S
OHARA, MD
GIBBONS, G
GOLDBERG, B
机构
[1] THOMAS JEFFERSON UNIV,DEPT RADIAT ONCOL & NUCL MED,PHILADELPHIA,PA
[2] THOMAS JEFFERSON UNIV,DEPT RADIOL,PHILADELPHIA,PA
[3] THOMAS JEFFERSON UNIV,DEPT PATHOL,PHILADELPHIA,PA
来源
JOURNAL OF IMMUNOTHERAPY | 1994年 / 16卷 / 03期
关键词
BIOLOGICAL RESPONSE MODIFIERS; TUMOR BLOOD FLOW; RADIOLABELED MONOCLONAL ANTIBODIES; LASER DOPPLER FLOWMETRY; ULTRASOUND COLOR DOPPLER IMAGING; INTERFERON;
D O I
10.1097/00002371-199410000-00001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Human recombinant interferon-alpha-2b (IFN) is known to inhibit growth of both normal and tumor cells and to stimulate immune effector cell function. We have previously shown that IFN and other biological response modifiers augment accumulation of radiolabeled antibodies in tumors. This investigation demonstrates that 30 min post i.m. administration of IFN significantly (p < 0.01) enhances tumor perfusion in tumor-bearing mice and persists for a much longer time than in normal tissue, which, in part, may contribute to the enhanced tumor uptake of radiolabeled monoclonal antibodies within 1.5 h of their administration. Histological examinations of tumors obtained from animals receiving IFN 72 h previously did not show changes in inflammatory cells. Our investigation shows that laser Doppler flowmetry and color Doppler imaging can provide an excellent means of measuring tumor perfusion changes in small living animals where radioactive tracers cannot be used.
引用
收藏
页码:175 / 180
页数:6
相关论文
共 50 条
  • [41] MEASUREMENT OF THE CORONARY BLOOD-FLOW
    CHEYRETOVA, E
    IVANOV, G
    MARINOV, V
    SOTIROV, G
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1979, 4 (02): : 115 - 115
  • [42] MEASUREMENT OF BLOOD-FLOW BY CONDUCTIMETRY
    HANSS, M
    VULPILLA.M
    ANNALES DE PHYSIQUE BIOLOGIQUE ET MEDICALE, 1972, 6 (01): : 43 - &
  • [43] BONE BLOOD-FLOW MEASUREMENT
    TOTHILL, P
    JOURNAL OF BIOMEDICAL ENGINEERING, 1984, 6 (04): : 251 - 256
  • [44] HEPATIC BLOOD-FLOW MEASUREMENT
    NXUMALO, JL
    TERANAKA, M
    SCHENK, WG
    ARCHIVES OF SURGERY, 1978, 113 (02) : 169 - 172
  • [45] MEASUREMENT OF SKIN BLOOD-FLOW
    BARHAM, JB
    HYER, S
    TAYLOR, DN
    WILSON, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (02): : 288 - 288
  • [46] BONE BLOOD-FLOW MEASUREMENT
    REEVE, J
    GREEN, JR
    TELLEZ, M
    VEALL, N
    BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (679): : 659 - 660
  • [47] MEASUREMENT OF SKIN BLOOD-FLOW
    PAYNE, PA
    ELECTRONICS AND POWER, 1984, 30 (03): : 219 - 221
  • [48] TUMOR VESSEL INNERVATION, INFLUENCE OF VASOACTIVE DRUGS, AND CONTROL OF TUMOR BLOOD-FLOW
    PETERSON, HI
    MICROVASCULAR RESEARCH, 1983, 26 (01) : 130 - 130
  • [49] MEASUREMENT OF CORONARY BLOOD-FLOW .1. EXTERNAL MEASUREMENT OF CORONARY BLOOD-FLOW BY RADIOISOTOPES
    VACHERON, A
    VERNEJOU.PD
    HEULIN, A
    PAILLEUR, CL
    DELARUE, F
    DIMATTEO, J
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1974, 67 (04): : 397 - 403
  • [50] INFLUENCE OF ETHANOL AND AMBIENT-TEMPERATURE ON SKIN BLOOD-FLOW
    HUGHES, JH
    HENRY, RE
    DALY, MJ