ENDOCYTOSIS OF BETA-2 INTEGRINS BY STIMULATED HUMAN NEUTROPHILS ANALYZED BY FLOW-CYTOMETRY

被引:44
|
作者
CHAMBERS, JD [1 ]
SIMON, SI [1 ]
BERGER, EM [1 ]
SKLAR, LA [1 ]
ARFORS, KE [1 ]
机构
[1] UNIV NEW MEXICO,SCH MED,ALBUQUERQUE,NM 87131
关键词
CD18; INTERNALIZATION; MONOCLONAL ANTIBODY; FLUORESCENT PROBE; RECEPTOR CYCLING;
D O I
10.1002/jlb.53.4.462
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Flow cytometry and fluorescently labeled monoclonal antibodies were used to investigate endocytosis of human neutrophil beta2 integrins following cellular activation. CD18 initially present on the cell surface cycled in two phases after exposure to formyl peptide or platelet-activating factor. The first phase lasted 3 min at 37-degrees-C; after a lag, CD18 was specifically internalized at approximately 20%/min. Subsequently a second phase was detectable consisting of exponential reduction of internal fluorescence with a half-time of approximately 2 min, representing probe reexpression. At peak endocytosis approximately 40% of CD18 was internalized. All of the internalized CD18 was associated with alpha(M) (CR3), no endocytosis Of alpha(L) (LFA-1) was observed. When neutrophils were stimulated with phorbol esters or calcium ionophore, CD18 was internalized much more slowly (t1/2 = 5 min) and probe was not reexpressed. Endocytosis of CD18 may participate in regulating neutrophil adhesiveness, removing activated receptors, or permitting receptor recycling.
引用
收藏
页码:462 / 469
页数:8
相关论文
共 50 条
  • [31] CELL-CYCLE-DEPENDENT EXPRESSION OF HUMAN-MELANOMA MEMBRANE ANTIGEN ANALYZED BY FLOW-CYTOMETRY
    LEONG, SPL
    BOLEN, JL
    CHEE, DO
    SMITH, VR
    TAYLOR, JC
    BENFIELD, JR
    KLEVECZ, RR
    CANCER, 1985, 55 (06) : 1276 - 1283
  • [32] T-ANTIGEN VARIABILITY IN A HUMAN URINARY-BLADDER CARCINOMA LINE ANALYZED BY FLOW-CYTOMETRY
    COON, JS
    WATKINS, JR
    PAULI, BU
    WEINSTEIN, RS
    FEDERATION PROCEEDINGS, 1985, 44 (03) : 417 - 417
  • [33] ACTIVATION OF NEUTROPHILS - MEASUREMENT OF ACTIN CONFORMATIONAL-CHANGES BY FLOW-CYTOMETRY
    PACKMAN, CH
    LICHTMAN, MA
    BLOOD CELLS, 1990, 16 (01): : 193 - 207
  • [34] APPLICATION OF FLOW-CYTOMETRY TO STUDIES ON THE HUMAN ACROSOME
    PURVIS, K
    RUI, H
    SCHOLBERG, A
    HESLA, S
    CLAUSEN, OPF
    JOURNAL OF ANDROLOGY, 1990, 11 (04): : 361 - 366
  • [35] beta(2) Integrins are not required for tyrosine phosphorylation of paxillin in human neutrophils.
    Fernandez, R
    Boxer, LA
    Suchard, SJ
    MOLECULAR BIOLOGY OF THE CELL, 1996, 7 : 1400 - 1400
  • [36] FLOW-CYTOMETRY (FCM) OF HUMAN TESTICULAR TISSUE
    PFITZER, P
    GILBERT, P
    ROLZ, G
    VYSKA, K
    CYTOMETRY, 1981, 2 (02): : 120 - 120
  • [37] HUMAN-CHROMOSOME ANALYSIS BY FLOW-CYTOMETRY
    YOUNG, BD
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1985, 450 (JUN) : 11 - 23
  • [38] beta(2) integrins are not required for tyrosine phosphorylation of paxillin in human neutrophils.
    Fernandez, R
    Boxer, LA
    Suchard, SJ
    BLOOD, 1996, 88 (10) : 56 - 56
  • [39] DNA FLOW-CYTOMETRY IN HUMAN TESTICULAR CANCER
    FOSSA, SD
    PETTERSEN, EO
    THORUD, E
    MELVIK, JE
    OUS, S
    CANCER LETTERS, 1985, 28 (01) : 55 - 60
  • [40] CELL-SURFACE RETROVIRUS-RELATED ANTIGEN ANALYZED BY FLOW-CYTOMETRY
    SZABO, G
    MATYUS, L
    ACTA BIOCHIMICA ET BIOPHYSICA HUNGARICA, 1983, 18 (1-2) : 19 - 19