LOW LIQUID-HELIUM CONSUMPTION CRYOSTAT FOR MAGNETORESISTIVITY MEASUREMENTS IN A NARROW GAP ELECTROMAGNET

被引:0
|
作者
WHITE, H [1 ]
MCLACHLAN, DS [1 ]
机构
[1] UNIV WITWATERSRAND,CONDENSED MATTER RES GRP,WITWATERSRAND 2050,SOUTH AFRICA
关键词
cryostats; helium; magnetoresistance; measuring techniques;
D O I
10.1016/0011-2275(90)90317-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
A cryostat for measuring the resistivity, magnetoresistivity and Hall coefficient of thin metallic films is described. The cryostat, which is designed to operate between 1.4 and 273 K, is mounted in a 30 mm gap between the poles of an iron-core electromagnet, capable of reaching 1.5 T. Liquid helium consumption is low (≈ 0.5 dm3 h-1). The cryostat is specifically designed for manufacture in a non-specialist workshop. © 1990.
引用
收藏
页码:365 / 367
页数:3
相关论文
共 50 条
  • [21] GALVANOMAGNETIC EFFECTS IN NARROW-GAP CDXHG1-XTE AT LIQUID-HELIUM TEMPERATURES
    BOVINA, LA
    SAVCHENKO, YN
    STAFEEV, VI
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1975, 9 (01): : 15 - 18
  • [22] CONSTRUCTION DETAILS OF A LIQUID-HELIUM CRYOSTAT FOR A SUPERCONDUCTING OBJECTIVE AND COLD STAGE
    LAMVIK, MK
    WORSHAM, RE
    KOPF, DA
    ROBERTSON, JD
    ULTRAMICROSCOPY, 1984, 12 (1-2) : 79 - 82
  • [23] INFRARED MEASUREMENTS OF SURFACE ELECTRONS ON LIQUID-HELIUM
    LAMBERT, DK
    RICHARDS, PL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (03): : 473 - 473
  • [24] LIQUID-HELIUM CRYOSTAT COUPLED TO AN ELECTROMAGNETIC ISOTOPE SEPARATOR FOR INSITU MOSSBAUER-EFFECT MEASUREMENTS ON IMPLANTED SOURCES
    DRENTJE, SA
    REINTSEMA, SR
    NUCLEAR INSTRUMENTS & METHODS, 1976, 133 (03): : 421 - 424
  • [25] STABILIZING A LASER-BEAMS FOCAL POINT INSIDE A LIQUID-HELIUM CRYOSTAT
    JAFFE, SM
    YEN, WM
    GRILL, W
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02): : 325 - 330
  • [26] CRYOSTAT FOR COLLECTION OF 3-DIMENSIONAL DIFFRACTOMETER DATA AT LIQUID-HELIUM TEMPERATURES
    COPPENS, P
    ROSS, FK
    BLESSING, RH
    COOPER, WF
    LARSEN, FK
    LEIPOLDT, JG
    REES, B
    LEONARD, R
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1974, 7 (JUN1) : 315 - 319
  • [27] VARIABLE TEMPERATURE LIQUID-HELIUM CRYOSTAT FOR UV-SPECTROSCOPY AND IR-SPECTROSCOPY
    FREDIN, L
    ROSENGREN, K
    SUNNER, S
    CHEMICA SCRIPTA, 1973, 4 (02): : 93 - 95
  • [28] LIQUID-HELIUM GONIOMETER-MOUNTED CRYOSTAT FOR A SINGLE CRYSTAL AUTOMATIC NEUTRON DIFFRACTOMETER
    ABRAHAMS, SC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1960, 31 (02): : 174 - 176
  • [29] Design and performance of a miniature cryostat for emission measurements in liquid helium
    Jasny, Jan
    Slenczka, Alkwin
    Dick, Bernhard
    Zeitschrift fur Physikalische Chemie, 2001, 215 (12): : 1565 - 1573
  • [30] Design and performance of a miniature cryostat for emission measurements in liquid helium
    Jasny, J
    Slenczka, A
    Dick, B
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2001, 215 : 1565 - 1573